AeroAudio MOS QUATRO IP User manual

1
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
MOS QUATRO IP
MANUAL
INDEX
Connections............................................................................................................................... 2
XLR .............................................................................................................................................. 3
Netwerk access......................................................................................................................... 4
Reset settings to factory default............................................................................................ 4
MOS Quatro IP settings ..........................................................................................................5
Light settings .............................................................................................................................. 5
Methods ...................................................................................................................................... 5
Method 1:TCP commando’s / strings...................................................................................6
Method 2:Telos Axia x-node / livewire driver.................................................................... 7
Method 3:Telos Axia QOR/IQ/IQX...................................................................................... 8
Method 4: DHD logic...............................................................................................................9
Safety First!...............................................................................................................................10

2
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
MOS QUATRO IP
MANUAL
The MOS Quatro IP is a four-way 19 inch microphone on-air switch for switching microphone
lighting on for example theYellowtec Mika microphone arms.
The four microphone ports switch separately from each other.
The indication LED’s on the front panel of the MOS Quatro IP shows the status of each microphone.
These LED’s indicates whether the microphone arms are on standby, xed white light, or fading in
and out.
The status LED tells You the status of the white lights. If this LED is on, the function of the white
lights are set for fading. If this LED is off, then the white lights are xed.
Up to 4 microphone arms can be connected to the rear panel of the MOS Quatro IP. The MOS
Quatro IP will control the lights of the connected arms in red for on-air and white for off-air.
The audio signal is routed directly from the connected microphone arm to a standard 3-pin XLR
connector.
Connections from left to right
Power
9 to 18 volts DC
RJ11
Link connection for synchronisation with other MOS (Uno or Quatro)
Link1 = master and Link2 = slave
You need this link only when the white led’s are set to fading (statusled is on)
To activate or deactivate this function see chapter “light settings” on page 5
ETHERNET
Ethernet network connection
It is best to ground the device or place the device in a rack that is properly earthed to prevent static
discharge, should this happen please reboot the device.

3
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
MOS QUATRO IP
MANUAL
XLR 3p male
Microphone 2 output audio signal
XLR 5p female
Microphone arm 3
XLR 3p male
Microphone 3 output audio signal
XLR 5p female
Microphone arm 4
XLR 3p male
Microphone 4 output audio signal
Dimensions
19 inch, 1HE
Depth: 22.2cm
Weight: 2.6kg
XLR 3p male
Microphone 1 output audio signal
XLR 5p female
Microphone arm 2
Pin Function Type
1 Shield Shield
2 Signal + Input
3 Signal - Input
Pin Function Type
1 Shield Shield
2 Signal + Input
3 Signal - Input
4 LED + 12 volt Output
5 Led – 12 volt Output
XLR 5p female
Microphone arm 1

4
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
MOS QUATRO IP
MANUAL
Netwerk access
The MOS Quatro IP settings can be
adjusted using a standard webbrowser.
The factory default settings:
IP 192.168.0.101
Subnetmask: 255.255.255.0
It may take up to 30 seconds for the
device to be active on the network
after connecting the device to your
computer or network.
Enter the IP address in your browser
and the MOS Quatro IP will display the
following settings page:
Reset settings to factory
default
Reset to default setting can be done
by sending the restore command
on port 4009 at broadcast address
255.255.255.255.
Use packetsender to do this.
link to reset program

5
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
MOS QUATRO IP
MANUAL
MOS Quatro IP settings
Here the IP address with the corresponding subnet mask can be set.The MAC address is unique for
each device and can not be changed. The rmware shows the currently running rmware version of
the device.
To activate and save the settings press “Save settings and reboot.”
Light settings
White Coninuous: When microphone is OFF, white light will be ON.
White Fading: When microphone is OFF, white light will be ON and will be fading after 1 minuut.
White Inactive: When microphone is OFF, white light is also OFF.
To activate and save the settings press “Save settings and reboot.”
Methods
There are 4 methods to work with MOS Quatro IP:
• METHOD 1:TCP COMMANDO’S / STRINGS
• METHOD 2:TELOS AXIA X-NODE / LIVEWIRE DRIVER
• METHOD 3:TELOS AXIA QOR/IQ/IQX
• METHOD 4: DHD LOGIC

6
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
MOS QUATRO IP
MANUAL
METHOD 1: TCP COMMANDO’S / STRINGS
Remote device settings: select “TCP commands”
Remote IP: not used in this method
To activate and save the settings press “Save settings and reboot.”
MIC 1 (same for MIC 2, MIC 3 and MIC 4)
TCP ON: string to activate MIC 1 to ON (red)
TCP OFF: string to de-activate MIC 1 to OFF (white or no color)
You can activate this command by sending the specic string to the IP address of the MOS Quatro IP
and port 93.
In this example 192.168.0.101 port 93
To activate and save the settings press “Save settings and reboot.”

7
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
MOS QUATRO IP
MANUAL
METHOD 2: TELOS AXIA X-NODE / LIVEWIRE DRIVER
Remote device settings: select “Axia X-node”
Remote IP: enter the IP address of the X-node/livewire
In this example 192.168.0.100 - Make sure that devices are in the same IP-range.
To activate and save the settings press “Save settings and reboot.”
MIC 1 (same for MIC 2, MIC 3 and MIC 4)
GPIO: Select your GPIO contact and designated PIN
In this example “GPI1” and “PIN 1”
TCP ON and TCP OFF: not used in this method
To activate and save the settings press “Save settings and reboot.”
After save settings and reboot, if the device is found it wil show “connected”
If not it will show “not connected”
Please check if your device is correct-
ley connected and the IP address is set
correct.

8
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
MOS QUATRO IP
MANUAL
METHOD 3: TELOS AXIA QOR/IQ/IQx
Remote device settings: select “Axia QOR/IQx”
Remote IP: enter the IP address of the QOR/IQx
In this example 192.168.0.1 - Make sure that devices are in the same IP-range.
To activate and save the settings press “Save settings and reboot.”
MIC 1 (same for MIC 2, MIC 3 and MIC 4)
Channel Name: enter source name of your microphone like you use in the QOR/IQx source
prole. In this example “MIC1”
To activate and save the settings press “Save settings and reboot.”
Make sure for the rst use to reload the show prole of your studio console.
If for any reason the MOS Quatro IP doesn’t react on the commands of the QOR/IQx (this can be
caused by power reboot of the QOR/IQx or too fast loading of the show proles) then please try to
reload the show prole on the QOR/IQx.
If not it will show “not connected”
Please check if your device is correct-
ley connected and the IP address is set
correct.

9
METHOD 4: DHD LOGIC
Remote device settings: select “DHD logic”
Remote IP: enter IP of the DHD device
In this example 192.168.0.1 - Make sure that devices are in the same IP-range.
To activate and save the settings press “Save settings and reboot.”
MIC 1 (same for MIC 2, MIC 3 and MIC 4)
DHD Project ID: enter your DHD Project ID, in this example “ARAU”
Global logic: enter your Global logic, in this example “1”
To activate and save the settings press “Save settings and reboot.”
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
MOS QUATRO IP
MANUAL

10
MOS QUATRO IP
MANUAL
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - INFO@AEROAUDIO.EU
Safety First!
- Caution: hot and sharp surfaces ! This professional device should only be installed by qualied personnel.
- Check the cardboard box for any damage upon receipt of the goods. In case of a damaged box, please contact your distributor
contact your distributor before opening the box.
- Read all documentation before using the unit.
- Keep all documentation for future use.
- Keep the box and packing materials even if the equipment has arrived in good condition.
- Should you ever need to ship the equipment, use only the original factory packaging.
- Do not spill water or other liquids in or on the unit.
- Always use the power supply provided.
- Make sure the outlets match the power requirements listed on the back of the power supply.
- Do not use the unit if the power cord is frayed or broken.
- Turn off and disconnect the devices from the power supply before making any connections.
- Do not use the unit near heaters, heating vents, radiators, or other devices that produce heat.
- Do not use the unit on a surface or in an environment that may interfere with the normal ow of air around the unit.
If the unit is used in an extremely dusty or smoky environment, the unit should be “dusted” periodically.
- Do not remove the cover. Removing the cover will expose you to potentially dangerous volt voltages.
- In case of malfunction, this unit should only be serviced by qualied service personnel.
- Always follow the instructions of the supplier and manufacturer - Use only manufacturer specied accessories, spare and replacement parts.
- Use the device only for the application the manufacturer intended.

11
F) TVVSOUND
pROJE C T
DECLARATION OF CONFORMITY
we,
acc. to art. 10.1 EMC directive 89/336/EEC
TVV SOUND PROJECT B.V.
STEENWEG 148C
9810 NAZARETH
BELGIUM
hereby declare, exclusively to our responsibility,that this product
MOS QUATRO IP Serialnrs.: 1- xxx
to which this declaration applies, is in accordance with the following harmonized European norms
EN 50081-1 and EN 50082-1
According to the regulations of the EMC-directive 89/336/EEG, amanded by directive
91 /263/EEG, 92/31 /EEG and 93/68/EEG.
en 60065
According to the regulations of IEC 65: 1985 +AI :1987 +A2: 1989 +A3: 1992, mod.
Ratification: 1993-07-06
Nazareth, January 16th 2023
Stamp:
Edo Dijkstra, managing director
Signature:
TVV SOUND
WWWW IVVSOUND.BE
-9810 BELGIUM 1' +32 (0)9 384 62 31 •INFO@IA/VSOUND.BE -
Table of contents
Other AeroAudio Switch manuals
Popular Switch manuals by other brands

Siemens
Siemens 3VT9300-2A.10 operating instructions

Nitrous Express
Nitrous Express 18959M quick start guide

ZyXEL Communications
ZyXEL Communications Dimension GS-3012F user guide

Endress+Hauser
Endress+Hauser Liquiphant FTL62 operating instructions

insys icom
insys icom ETSM Installation and operation manual

Amphenol
Amphenol RES-SCE-8MG manual