Aeroex ARO-400 Supplement

1
01/20
www.aeroex.com [email protected]
Aeroex Technologies Inc.
Oil Mist Collector
Model ARO-400/600
Multi-Stage
Installation & Service Manual
www.aeroex.com
705-734-0199
sales@aeroex.com
orderdesk@aeroex.com

2
01/20
www.aeroex.com [email protected]
Table of Contents
Specifications…………………………………….………….…………3
Installation instructions……….……….......…………….……………4
Installation Kit.................................................................................5
Oil drain hose Kit............................................................................5
Electrical Connection.....................................................................6
Direction of rotation........................................................................6
Wiring Connection..........................................................................7
Maintenance...................................................................................8
Filter options Coolant......................................................................9
Filter options Oil..............................................................................10
Dimensions.....................................................................................11
Warranty.........................................................................................12

3
01/20
www.aeroex.com [email protected]
Model ARO-400/600 Specifications
AEROEX – Oil Mist Collector
For highly effective separation of coolant and oil mists including smoke from metalworking
machinery and oil reservoirs.
Consisting of:
Powdered coated mild steel housing.
Motor and fan impeller.
-For Coolant, the primary separation pack consists of a 1st stage ME and 2nd stage AG agglo,
3rd stage fiber bed filter. Final filtration, 4th stage HEPA filter.
-For Oil, the primary separation pack consists of a 1st stage ME and 2nd and 3rd stage multi-layer
fiber bed filter. Final filtration, 4th stage HEPA filter.
Specifications:
Model
CFM
Sound
dB(A)
Machine
Tool
Enclosure
Volume ft³
Motor
hp
Voltage
RPM
Amps
RPM
ARO-400
6” inlet
350-500
68
125
1.0
External
Motor
230/3/60
460/3/60
575/3/60
3.2
1.3
1.2
3450
ARO-600
6” inlet
600-700
70
200
1.0
External
Motor
230/3/60
460/3/60
575/3/60
3.2
1.3
1.2
3450
ARO-600
8” inlet
700-800
70
250
1.0
External
Motor
230/3/60
460/3/60
575/3/60
3.2
1.3
1.2
3450
Model
Dimensions
Weight
Duct Con.
ARO-
600
43” x 21” x 41”ht (1092 x 533 x 1041 mm)
190-230 lb. (104
kg)
6” (152 mm) or
8” (200mm)

4
01/20
www.aeroex.com [email protected]
Installation Instructions
•Mount mist collector level.
•Units can be mounted directly on top of machines, on a post or on the wall.
•Ensure that there is free space to change filters.
•Minimize the length of ducting to avoid air flow loses.
•Metal ducting or flexible hose can be used.
•Do not locate suction intake on machining applications in direct line of the cutting spray.
•Install chip strainer. See details next page
•Connect the oil drain line using loop in hose or pee trap.
•Loop in hose must be minimum 8” below mist collector, no max. See instructions page 5.
•Fill loop with water or oil to create air lock.
•Install motor starter and set overloads.
•Connect electrical power.
•Check motor direction as per arrow on motor.
Typical installation:

5
01/20
www.aeroex.com [email protected]
Installation Kit
Three (3) standard installation kits as follows:
Item
Description
Qty
Part #
1
Installation Kit, 6”, with large chip strainer
1
099AIK-0002
1(a)
Suction hose 6”
5ft
099MPH-0006
1(b)
Hose clamp 6”
1
099MHH-0005
1(c)
Machine adaptor 6”
1
099AMS-0006
1(d)
Chip strainer, 6.5” x 8” x 3¼”
1
099ACS-0004
1(d)
Optional chip deflector
1
099ACD-0004
2
Installation Kit, 8”
1
099AIK-0003
2(a)
Suction hose 8”
5ft
099MPH-0008
2(b)
Hose clamp 8”
1
099MHH-0006
2(c)
Machine adaptor 8”
1
099AMS-0008
2(d)
Chip strainer, 8” x 10” x 4”
1
099ACS-0005
2(d)
Optional chip deflector
1
099ACD-0005
Oil Drain Hose Kit
Item
Description
Qty
Part #
1
Drain Hose Kit, c/w
1
099MPH-0013
1(a)
Oil drain hose
10ft
099MPH-0004
1(b)
Oil drain bracket
1
A99SPM-0002
1(c)
Nipple
1
099MPB-0001
1(d)
Hose clamp
1
099MHH-0002
Installation:
Loop in oil drain hose is required
to create air lock.
Fill with water, coolant or oil.
Failure to install correctly will
result in no oil draining

6
01/20
www.aeroex.com [email protected]
Electrical Connection
Electrical installation must be performed by a qualified electrical technician and comply with
applicable local codes. The motor must have overload protection set to the correct motor
amperage.
Most electrical technicians/contractors will be able to supply motor starter panel or install
motor contactor in cnc machine electrical panel.
Aeroex offers a selection of motor starter panels as listed below:
1
Manual Motor Starter
Start/stop, overloads, no
pilot light
4
Motor Starter Panel
Remote control with 24
VDC signal
Fused disconnect switch,
overloads, pilot light.
2
VFD Motor Starter Panel
Fused disconnect switch,
start/stop,
overloads, pilot light.
5
VFD Motor Starter
NEMA 4X enclosure.
3
Motor Starter Panel
Fused disconnect switch,
start/stop,
overloads, pilot light.
Mount the motor starter control panel in a convenient location.
Machine mounted mist collectors can be wired into the CNC electrical control.
Connect electrical wires on dual voltage motors (230/460/3/60) according to wire numbers on
the motor data plate or the motor manual.
Direction Of Rotation
External Motor: (ARO-600)
- Motor direction arrow is located on the motor
- Start/Stop motor
- Check rotation direction
- If incorrect, switch 2 electrical connections, i.e. L1 & L2 (3 phase only)
- Recheck

8
01/20
www.aeroex.com [email protected]
Maintenance
The mist collector can operate for long periods without maintenance. The maintenance period will
depend on the type of oil, coolant & debris in air stream. Inspect the unit after 3 months, 6 months
& 1 year to establish the maintenance interval.
The mist collector has one magnehelic gauge measuring the pressure drop on 4th stage HEPA
filter. Should the gauge reduce to near zero, this indicates no air flow going to HEPA filter, check
filter stages 1 to 3 and chip strainer.
HEPA filter replacement:
Replace when magnehelic pressure gauge
reaches the red zone.
Note:
If filter stages 1 – 3 or chip strainer are plugged, no air flow
will go to 4th stage HEPA filter and pressure reading can
reduce.

9
01/20
www.aeroex.com [email protected]
Coolant Filter Options
Note:
Please check filter part # installed in mist collector.
Item #
Description
Part Number
1
1st stage “ME” Mechanical Element
A06FMS-0001
2
2nd stage “AF” Coolant Filter
A06FAF-0001
3
3rd stage “CM” Coolant Mist Filter
A06FCM-0004
4
4th stage “HF” HEPA Filter 95% @ 0.3
microns
600HF-2095
4
4th stage “HF” HEPA Filter HEPA 99.97% @
0.3 microns
(Optional)
600HF-2099
4
4th stage “HF” Odor-Rid HEPA Filter
(Optional)
600HF-3095

10
01/20
www.aeroex.com [email protected]
Oil Filter Options
Note:
Please check filter part # installed in mist collector.
Item #
Description
Part Number
1
1st stage “ME” Mechanical Element
A06FMS-0001
2
2nd stage “OM#5” Oil Mist Fibre Bed Filter
A06FOM-0005
3
3rd stage “OM#7” Oil Mist Fibre Bed Filter
A06FOM-0007
4
4th stage “HF” HEPA Filter 95% @ 0.3
microns
600HF-2095
4
4th stage “HF” HEPA Filter HEPA 99.97% @
0.3 microns
(Optional)
600HF-2099
4
4th stage “HF” Odor-Rid HEPA Filter
(Optional)
600HF-3095

12
01/20
www.aeroex.com [email protected]
Warranty
Limited Warranty
Aeroex warrants the original purchaser against defects in material and workmanship for five (5)
years from date of shipment.
Filters are consumable items and are only warranted to be free of manufacturing defects at time of
delivery.
Equipment, parts, or accessories manufactured by others including electric motor, fans and control
components carry the guaranty of the manufacturer only.
Any part which is determined to be defective in material or workmanship and returned to an
authorized service location, as Aeroex Technologies designates, shipping costs prepaid, will be
repaired or replaced at Aeroex Technologies option.
Excluded from the foregoing guarantee are damages caused by ordinary wear and tear, erosion or
corrosion, misuse, abuse, or improper handling by the purchaser or any third party.
Aeroex Technologies makes no additional warranties, expressed or implied, whether of
merchantability, or otherwise, other than stated above. AEROEX shall not be responsible for any
indirect, special or consequential damages, nor for any other claim arising out of the sale, rental, or
use of its equipment. AEROEX shall not be liable for special or consequent damages in case of any
failure, claims for labour, loss of profits, repairs, alterations, or other expenses incidental to
replacement of defective parts or return of the equipment. The Purchaser's sole remedy shall be as
stated above.
Aeroex Technologies will make good faith effort for prompt correction or adjustment with respect to
any product that proves to be defective within warranty.
Aeroex Technologies Inc.
17 Hamilton Road
Barrie ON, L4N 8Y6
705-734-0199
orderdesk@aeroex.com
www.aeroex.com
This manual suits for next models
1
Table of contents
Other Aeroex Air Cleaner manuals