Parameter/part Value/description
General specication
Dimensions (Wx H x D) 81 x 81 x 22 mm
Ambient temperature 5÷50ºC
Temperature setting range 5÷35ºC
Sensor measurement error +/- 0.5ºC
Electrical parameters
Power supply 2xAAA 1.5 V batteries (LR03)
Load capacity of the contact 1 A/250 V AC
Permissible cable type 2x0,5 mm2
Technical data
Operation
2
Hysteresis - permissible deviation from setpoint temperature. Hysteresis is to prevent
undesirable clocking of the controlled device with small temperature uctuations.
Hysteresis setting is possible in the range of 0.2÷4°C.
Entering the
menu: hold
down “+”
and “-”
Sensor compensation. Compensation should be carried out if the room temperature
measured by the sensor of the RT01 thermostat is signicantly different from the actual
temperature.
Key lock.
Battery status.
Resetting to factory settings.
Decommissioning, scrapping
1. Disconnect the power supply from the device.
2. Remove the device.
3. In order to protect the environment, the decommissioned appliance must not be disposed of with
unsorted household waste. The device must be delivered to asuitable disposal point.
RT01 thermostats are made of recyclable materials.
Guarantee
Customer satisfaction
Addresses
Product warranty in accordance with the general conditions of sale and delivery. The guarantee becomes void as
aresult of arbitrary alterations or installation not in accordance with this installation and operation manual.
For AFRISO, customer satisfaction is the most important thing. If you have any questions, suggestions or problems with
the product, please contact us.
The addresses of companies representing the AFRISO group worldwide can be found at www.afriso.com.
Switching between heating mode and cooling mode .
Heating mode: lights – when the room needs reheating
is invisible – when the room is warmed up
Cooling mode: ashes – when the room needs to be cooled
is invisible - when the room is chilled