AFRISO FloorControl RT05 User manual

953.011.0090
AFRISO-EURO-INDEX GmbH
Lindenstr. 20
D-74363 Güglingen
www.afriso.com
Service AFRISO
Tel. 07135 102 0
service@afriso.de
Installation and Operation Manual
FloorControl RT05
programmable room thermostat
+ Read the manual before using the device!
+ Pay attention to all safety information!
+ Keep the installation and operation manual!

2 FloorControl RT05 programmable room thermostat
Contents
1 Explanation of the installation and operation manual.................... 4
2 Safety............................................................................................ 4
2.1. Warning Signs............................................................................ 4
2.2. Intended use ............................................................................. 5
2.3. Quality control .......................................................................... 5
2.4. Authorised to operate ............................................................... 5
2.5. Product modifications ............................................................... 5
2.6. Use of additional parts and accessories ..................................... 5
2.7. Responsibility............................................................................ 6
3 Description of the device............................................................... 6
3.1. Construction.............................................................................. 8
3.2. Dimensions ............................................................................... 9
3.3. Operation.................................................................................. 9
3.4. Versions .................................................................................... 9
3.5. Example application diagrams ................................................. 10
3.6. Technical data ......................................................................... 11
3.7. Approvals, certificates, conformity .......................................... 12
4 Transport and storage................................................................. 12
5 Assembly and start-up................................................................. 12
5.1. Wall mounting......................................................................... 13
5.2. First start-up............................................................................ 13
5.3. Electrical connections.............................................................. 14
5.3.1. Connections to the WB01 D-8 box ................................... 14
5.3.2. Compatibility with WB01 D-8 wiring boxes ...................... 15
5.3.3. Connections to other heating devices .............................. 15
6 Operation of FloorControl RT05 thermostat ................................ 16

FloorControl RT05 programmable room thermostat 3
6.1. Main screen ............................................................................ 16
6.2. Operating modes..................................................................... 17
6.2.1. Manual mode .................................................................. 17
6.2.2. Day/night......................................................................... 18
6.2.3. Weekly mode................................................................... 19
7 Navigating through the menu and editing parameters................. 20
7.1. Menu diagram......................................................................... 21
7.2. Day of the week ...................................................................... 21
7.3. Hour........................................................................................ 22
7.4. Day from…............................................................................... 22
7.5. Night from…............................................................................ 23
7.6. Optimum Start ........................................................................ 23
7.7. Service menu........................................................................... 25
7.7.1. Switching between heating and cooling modes................ 26
7.8. Weekly programme................................................................. 26
7.8.1. Selection of the current weekly programme .................... 26
7.8.2. Weekly program configuration ........................................ 27
7.9. Comfort temperature.............................................................. 29
7.10. Energy-saving temperature ..................................................... 29
7.11. Hysteresis................................................................................ 30
7.12. Sensor compensation .............................................................. 30
8 Decommissioning, scrapping ....................................................... 31
9 Customer satisfaction.................................................................. 32
10 Guarantee................................................................................... 32

4 FloorControl RT05 programmable room thermostat
1Explanation of the installation and operation manual
The installation and operation manual is an important part of the
delivery. That's why we recommend to:
Read the installation and operation manual before installing
the unit.
Keep the installation and operation manual throughout the
lifecycle of the unit.
Transfer the installation and operation manual to any
subsequent owner or user.
The following references appear in this manual:
“Applies to 230 V version:” and “Applies to battery version:”.
The content in the relevant section of themanual under “Applies to the
battery version:” refers only to the Programmable room thermostat
FloorControl RT05 for WB01 D-8-24/230, battery-powered (Art. No.
86 020). The content in the relevant section of the manual under
“Applies to 230 V version:” refers only to the Programmable room
thermostat FloorControl RT05 for the WB01 D-8-230, 230 V AC (Art.
No. 86 019).
2Safety
2.1. Warning Signs
DANGER Shows the nature and source of the hazard.
Describes what to do to avoid danger
Hazards have 3 levels:
Hazard
Meaning
DANGER
Imminent danger!
Failure to comply will result in death or
serious injury.
WARNING
Possible danger!
Failure to comply may result in death
or serious injury.
NOTE
Hazardous situation!
Failure to comply may result in slight to
medium injury or material damage.

FloorControl RT05 programmable room thermostat 5
2.2. Intended use
The FloorControl RT05 programmable room thermostatis designed to
control (on/off) a heating or cooling device, such as a gas or electric
boiler.
The RT05 room thermostat may be connected to the FloorControl
WB01 D-8 underfloor heating wiring box to control the floor heating
system.
Any use other than those referred to in 2.2 is prohibited.
2.3. Quality control
The design of the FloorControl RT05 programmable room thermostat
complies with the current state of the art and technical safety
standards. Each device is checked for safety before shipment.
The product should only be used in an unobjectionable
technical condition. Read the installation and operation
manual and observe all applicable safety regulations.
Applies to the 230 V version:
WARNING The mains voltage (AC 230 V AC) can cause
serious injury or death.
Do not allow the device to come into contact with water.
Disconnect the device from the power supply before
dismantling the housing.
Disconnect the device from the power supply before
servicing.
Do not make any modifications to the device.
2.4. Authorised to operate
To avoid operating errors and accidents, make sure that all persons
using the device are familiar with its operation and chapter 2 of this
manual. Work on electrical circuits should only be carried out by an
authorised electrician.
2.5. Product modifications
Changes or modifications made by unauthorised persons may cause
hazards and are prohibited for safety reasons.
2.6. Use of additional parts and accessories
The use of inappropriate additional parts and accessories may
damage the device.
Use only original manufacturer's spare parts and
accessories.

6 FloorControl RT05 programmable room thermostat
2.7. Responsibility
The manufacturer is not liable for direct damage or its consequences
resulting from inaccurate reading of the installation and operation
manual, guidelines and recommendations.
The manufacturer and the seller of the device are not responsible for
damages and costs incurred by the user or third parties using the
device, in particular for damages resulting from use not in accordance
with the intended use indicated in chapter 2.2 of the installation and
operation manual, improper or defective connection or maintenance
and operation not in accordance with the manufacturer's
recommendations.
AFRISO makes every effort to ensure that the information materials
do not contain errors. If you find errors or inaccuracies in thefollowing
installation and use instructions, please contact us.
3Description of the device
The FloorControl RT05 programmable thermostat is a compact device
with a display that allows precise programmming of the temperature
in a room or rooms according to the day and time. The use of
FloorControl RT05 in a room provides thermal comfort and reduces
unnecessary heat loss.
FloorControl RT05 is available in two versions: battery powered
(2xAAA) and supplied with 230 V AC mains voltage.
The FloorControl RT05 room thermostat is dedicated to the
FloorControl WB01 D-8 underfloor heating wiring box to control the
floor heating system.
The FloorControl RT05 thermostat may be used to control a heating
or cooling device, such as a gas or electric boiler.
The RT05 thermostat consists of the main part with display and a rear
part for mounting in a mounting box. The rear part can be
disconnected by turning it counterclockwise (OPEN arrow). The rear
part can be reattached by inserting it into the main part and locking it
in place when turned clockwise (CLOSE arrow).

FloorControl RT05 programmable room thermostat 7
direction of
rotation -
disconnection
direction of
rotation -
attachment
rear part
main part
Figure 1: Disconnecting the rear of the thermostat.
The FloorControl RT05 programmable thermostat, battery-powered
version (Art. No. 86 020), may be connected to both versions of the
WB01 D-8 underfloor heating wiring box
(230 V AC - Art. No. 86 013 or 24 V DC - Art. No. 86 014).
The FloorControl RT05 programmable thermostat supplied with 230 V
AC mains voltage (Art. No. 86 019) can only be connected to a wiring
box supplied with 230 V AC mains voltage (Art. No. 86 013).

8 FloorControl RT05 programmable room thermostat
3.1. Construction
Pressing the button activates weekly or day/night
mode. After entering the menu, the button is used to
approve the settings and return to the main screen.
Pressing the button switches to manual mode and
reduces the setpoint temperature. After entering the
menu, the button is used to change the settings of
individual parameters.
Pressing the button switches to manual mode and
increases the setpoint temperature. After entering the
menu, the button is used to change the settings of
individual parameters.
Press and hold the button to enter the menu. When
editing parameters, pressing the button will
confirm the changes made and move on to editing the
next parameter.
Figure 2: Structure and button description of the FloorControl RT05 thermostat
Housing
Display

FloorControl RT05 programmable room thermostat 9
3.2. Dimensions
Figure 3: Dimensions of the FloorControl RT05 thermostat
3.3. Operation
The FloorControl RT05 programmable room thermostatis designed to
maintain the desired room temperature. When the room temperature
drops below the programmed value, the thermostat opens the contact,
sending a signal to the heating device or the wiring box of the
FloorControl underfloor heating control system to increase it. In
cooling mode, the situation is reversed –if the room temperature rises
above the programmed value, the thermostat closes the contact,
thus sending a signal to the cooling unit to lower it.
The thermostat's advanced software allows it to operate in the
following modes:
weekly mode
- control on a weekly schedule,
day/night mode
- working in a day/night programme,
manual mode
- keeping the room temperature setpoint constant.
3.4. Versions
FloorControl RT05 thermostats are available in two versions.
1) FloorControl RT05 programmable room thermostat for WB01 D-
8-24/230 box, battery-powered (Art. No. 86 020) –left.
2) FloorControl RT05 programmable room thermostat for WB01 D-
8-230 box, 230 V AC (Art. No. 86 019) –right.

10 FloorControl RT05 programmable room thermostat
RT05 battery RT05 230 V
Figure 4: Versions of FloorControl RT05 programmable thermostats
3.5. Example application diagrams
FloorControl RT05
programmable
room thermostat
Wiring box
wired for underfloor
heating
FloorControl WB01
FloorControl RT01 room thermostats
TA3 room
thermostat
TSA 01
thermoelectric
actuators
ProCalida EF1
polyamide
manifolds for
surface heating
and cooling
TSA 02 FO
thermoelectric
actuators
Figure 5: Example application diagram –FloorControl RT05 thermostat
connected to FloorControl WB01 wiring box

FloorControl RT05 programmable room thermostat 11
Figure 6: Example application diagram –FloorControl RT05 programmable
room thermostat used to control a gas boiler.
3.6. Technical data
Table 1: Technical data for RT05 room thermostats
Parameter/part
Value/description
General specification
Dimensions (W x H x D)
125x83x42mm
Ambient temperature
5÷50ºC
Temperature setting
range
5÷35ºC
Sensor measurement
error
+/- 0.5ºC
Modes (programmes)
manual, day/night, weekly
Electrical parameters
Power supply
Art. No. 86 020: 2xAAA 1.5
V batteries (LR03) Art. No.
86 019: 230 V AC
Load capacity of the
contact
1 A/250 V AC
Gas boiler
FloorControl RT05 programmable
room thermostat

12 FloorControl RT05 programmable room thermostat
3.7. Approvals, certificates, conformity
RT05 programmable FloorControl room thermostats meet the
requirements of Directive 2014/35/EU of the European Parliament and
of the Council of 26 February 2014 on the harmonisation of the laws
of the Member States relating to the making available on the market
of electrical equipment designed for use within certain voltage limits
(Official Journal EU L 96, 29.03.2014, page 357) and Directive
2014/30/EU of the European Parliament and of the Council of 26
February 2014 on the harmonisation of thelaws of the Member States
relating to electromagnetic compatibility (Official Journal EU L 96 of
29.03.2014, page 79), Directive 2009/125/EC establishing a
framework for the setting of ecodesign requirements for energy-
related products and the Regulation of the Minister of
Entrepreneurship and Technology of 24 June 2019 amending the
Regulation on essential requirements for restricting the use of certain
non-hazardous substances in electrical and electronic equipment
implementing Directive (EU) 2017/2102 of the European Parliament
and of the Council of 15 November 2017 amending Directive
2011/65/EU on the restriction of the use of certain hazardous
substances in electrical and electronic equipment (Official Journal EU
L 305, 21.11.2017, p. 8).
Harmonised standards have been used for conformity assessment:
PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10.
4Transport and storage
NOTE Possible damage to the device during improper
transport.
Do not throw the device.
Protect against soaking, moisture, dirt and dust.
NOTE Possible damage to the during improper storage.
Store the device in a dry and clean room.
Protect against soaking, moisture, dirt and dust.
5Assembly and start-up
The RT05 thermostat's mounting location must provide protection
from the weather. The RT05 thermostat must not be installed
outdoors.

FloorControl RT05 programmable room thermostat 13
The RT05 thermostat is designed for wall mounting using a standard
Ø60 mm flush-mounted electrical junction box. It cannot be mounted
on a base or placed directly on a finished wall.
NOTE Possible damage to existing installations
When making openings in walls, special care must be
taken not to damage electrical cables or other existing
wires.
5.1. Wall mounting
Check whether the wall is strong and thick enoughand whether the RT05
thermostat will fit in the place of your choosing. Then place and fix a Ø60
mm electrical box in the opening. Disconnect the rear of the thermostat
(see chapter 3) from its main part by slightly turning it counterclockwise.
Fix the rear part to the box using the holes A, B or A and B (depending
on the type and the method of mounting the electrical box) marked in
Figure 7. Snap the main part of the thermostat onto the rear part by
slightly turning it clockwise.
Figure 7: Mounting holes
5.2. First start-up
Before the first start up:
1. Connect the thermostat with the corresponding wiring box
WB01 D-8 or heating device according to section 5.3.
Applies to the battery version:
2. Insert the batteries into the rear of the thermostat
Applies to the 230 V version:
2. Connect the power supply according to section 5.3
3. Install the thermostat in the wall in accordance with section
5.1.

14 FloorControl RT05 programmable room thermostat
5.3. Electrical connections
Make sure that the power supply is disconnected and secured against
accidental switching.
Observe health and safety regulations and other accident prevention
regulations. All applicable national legislation must also be complied
with. Applies to the 230 V version:
The FloorControl RT05 room thermostatis connected to 230
V AC.
______________________________ ________________
WARNING Do not allow the thermostat and electrical
cables to come into contact with water.
__ ________________
5.3.1.Connections to the WB01 D-8 box
Only one room thermostat can be assigned to a given zone on the
FloorControl WB01 D-8 box.
Make the connections to the box as shown in Figure 8, 9 or 10,
depending on your version.
Applies to the battery
version:
Figure 8: Electrical
connection of
thermostat RT05 with
WB01 D-8-24V box
Applies to the battery
version:
Figure 9: Electrical
connection of
thermostat RT05 with
WB01 D-8-230V box
Applies to the 230 V
version:
Figure 10: Electrical
connection of
thermostat RT05 with
WB01 D-8-230V box

FloorControl RT05 programmable room thermostat 15
5.3.2.Compatibility with WB01 D-8 wiring boxes
The 230V version of RT05 thermostat can be connected only to the
WB01-D8-230V box, while the battery version can be connected
both to the WB01-D8-230 box and to the WB01-D8-24 box. To
properly recognize your thermostat version refer to section 3.4.
5.3.3.Connections to other heating devices
The RT05 thermostat can be used to control (on/off) other heating or
cooling device such as a gasboiler. To control other heating devices,
we recommend using the battery version of FloorControl RT05
programmable thermostat (see section 3.4).
Such a connection should be made in accordance with the manual
of the heater you want to control.
Formost gas boilers, control isby potential-freecontact.Thiscontact
is previously bridged. You should:
1. Remove the bridge (the element shorting the two control
contacts).
2. Connect the two wires in place of the bridge.
3. Connect the wire to the thermostat connections
according to the following diagram.
Figure 11: Example of electrical connection of RT05 thermostat with a gas
boiler
bridge

16 FloorControl RT05 programmable room thermostat
6Operation of FloorControl RT05 thermostat
6.1. Main screen
Figure 12: The main screen and its icons.
1 –Day of the week
2 –Active energy-saving temperature
3 –Active comfort temperature
4 –Setpoint temperature
5 –Measured temperature
6 –Hour
7 –Day/night mode active
8 –Weekly mode active
9 –Manual mode active
10 –Clock settings , Day from... ,
Night from..
11 –Comfort temperature , Energy-
saving temperature Temperature sensor
compensation , Hysteresis setting
12 –Heating/cooling status icon
In heating mode:
when the desired temperature is reached in
the room
the icon looks like this: ,

FloorControl RT05 programmable room thermostat 17
when the desired temperature is not
reached in the room, the “sunshine” flashes
(pulsating).
In cooling mode:
when the desired temperature is reached in
the room
the icon has only 4 rays (looks like this:
), when the desired temperature is not
reached in the room
the rays are displayed alternately this way:
and this: (spinning).
Applies to the battery version:
13 –Battery level
To replace the battery, disconnect the main
part of the thermostat from the rear part –
see chapter 3.
6.2. Operating modes
The FloorControl RT05 room thermostat can operate in one of the
three operating modes described below (Chapters 9.2.1 to 9.2.3).
6.2.1.Manual mode
In manual mode, the temperature is set directly from the main screen.
Use the and buttons to set it.
Manual mode is activated automatically by pressing one of these
buttons.
When manual mode is activated, it becomes the current mode only
until the nearest programmed setpoint temperature change of the
previously active mode.
Example: It's 5:10pm. The weekly mode is active with a comfort
temperature of 22ºC and a programmed energy-saving temperature
change to 19ºC at 11:00pm. When you press and set the temperature
to 24ºC, manual mode is activated as the current mode. The
temperature of 24ºC will be maintained until 11:00pm, when it will
change to 19ºC and return to weekly mode.
The current operation of manual mode as active mode is indicated
by the icon .

18 FloorControl RT05 programmable room thermostat
Figure 13: Example of the main screen during manual operation.
Manual mode can be deactivated by pressing .
6.2.2.Day/night
In day/night mode, the desired temperature depends on the time. The
user enters a separate setpoint temperature for day (comfort
temperature) and night (energy-saving temperature) and the exact
times when the controller will start the day (time with comfort
temperature) and night (time with energy-saving temperature).
To activate the day/night mode, press and the icon will
appear on the screen.
Figure 14: Example of the main screen during day/night operation.
Manual mode operation active
Day/night mode operation active

FloorControl RT05 programmable room thermostat 19
6.2.3.Weekly mode
In the weekly mode, the user determines at which times and on which
days comfort temperature will be maintained, and on which it will
switch to energy-saving.
FloorControl RT05 programmable room thermostat allows 9 different
programmes.
The programmes are divided into 3 main groups:
programmes 1÷3
By selecting programme 1, 2 or 3, daily settings are made for all days
of the week at once.
Example: Comfort temperature of 21ºC was set from 5pm to 10pm,
and energy-saving temperature of 19ºC from 10pm to 5pm the
following day. As a result, the RT05 thermostat will maintain 19ºC at
3:40pm regardless of the day of the week.
programmes 4÷6
By selecting programme 4, 5 or 6, daily settings are made
separately for working days (Monday-Friday) and
the weekend (Saturday-Sunday).
Example: A comfort temperature of 21ºC was set from 5pm to 10pm,
and energy-saving of 19ºC from 10pm to 5pm the following day on
working days; comfort temperature of 21ºC was set from 8am to 11pm,
and energy-saving of 19ºC from 11pm to 8am on the weekend. As a
result, the RT05 thermostat will maintain 19ºC at 3:40pm on working
days and 21ºC at the same time on Saturday and Sunday.
programmes 7÷9
By selecting programme 7, 8 or 9, the daily settings are made
separately for each day of the week.
Example: You can set independent hours of comfort and energy-
saving temperature separately for each day. On Wednesday, the
comfort temperature can be set between 5pm and 10pm, on Friday
between 4pm and midnight, and on Saturday between 7am and
midnight.
The weekly mode is activated by pressing which results in the
icon appearing on the home screen.

20 FloorControl RT05 programmable room thermostat
Figure 15: Example of the main screen during weekly operation.
At the bottom of the screen, the hours for which the comfort
temperature is assigned are displayed. For the remaining hours,
invisible on thescreen, energy-saving temperatureisassigned(Figure
16).
Figure 16: Hours for which comfort temperature is assigned.
7Navigating through the menu and editing parameters
Navigating through the menu, editing parameters and operating all
functions is carried out using the , , and buttons. To
edit individual parameters, press . Pressing scrolls through
thermostat functions. The currently edited parameter will be
expressed graphically by a flashing icon, the others will be greyed out.
In order to change the parameter setting, use the buttons and
. After changing the parameter, approve it with (the change is
confirmed and you are forwarded to the next parameter) or with
(confirmation and return to the main screen).