4
Types of valves to be tested
The HT101V is designed to be compatible with “Any” valve on “Any” machine. Specific valve types require specific
control voltages to operate correctly. The following explains the differences. It is important to know what type of valve
you’re dealing with to insure the best level of diagnosis.
Solenoid Valves- A simple On/ Off valve that uses a charged coil to engage the valve. 12 Volts present activates the
coil and operates the valve. Removing 12 volts dis-engages the valve. Polarity normally doesn’t matter.
Motorized Ball Valves- These valves operate at full speed all the time. They many times will have three wires. Plus
12 volts constant, Ground or minus 12 volts, and a signal line. The signal wire uses 12 volts to open the valve and lack of
12 volts closes the valve. There are 4 wire motorized ball valves. Here 12 volts and ground are supplied constantly. The
other two wires signal open/ close by supplying 12 volts but reversing the polarity to signal open/ close.
Servo Control Valves- Servo valves are motorized valves designed to provide smooth control of open and close
operation. The speed of the valve is controlled by varying the voltage or drive to the motor. The motor operates at full
speed with 12 volts applied but will typically move slowly with as little as 3 volts or less. The polarity of the applied
control voltage controls the direction of operation. Control systems constantly change the control voltage to affect the
movement speed or response. As an example; a spray controller will run the control voltage to maximum when big
changes are required, then drastically drop the voltage as the target rate is reached. Fine tuning is performed at
minimum operating voltage. Servo valves may work perfectly at full voltage, “drive” but not move at all at low control
voltages.
PWM Valves- PWM means “pulse width modulated”. Modulate means, to change. PWM valves are closed when
there is no signal. The valve then begins to open as pulses are applied, so the valve is effectively opening and closing
with each pulse. The control signal voltage is turning on, then off, at a rate of about 100 times per second or 100Hz.
Applying a constant 12 volts to the PWM valve coil will run the valve at full speed.
An oscilloscope image shows the pulse width changing. The percentage of time ON is called the DUTY CYCLE.
ZERO VOLTS- 11 VOLTS- Drive Voltage changes from Zero to Eleven Volts, 100 times per second
ON about 25 percent of the time- ON about 50 percent of the time ON about 70 percent of the time
PWM Valves are two wire valves and look a lot like solenoid valves. RAVEN PWM valves reach full output at 55% drive.
DITHERING SERVO VALVES- 4 WIRE- Some servo control valves respond to PWM commands. The speed of the
valve is controlled by the pulse width of the drive signal rather than a varying drive voltage to control valve speed. They
have 4 wires with a constant Ground and Plus 12 Volts supplied. The control signal is pulse width modulated. Some
would call these valves, current controlled. RAVEN 4 wire FAST VALVES and DICKEY-john control valves are this type.