Manual
AGRETO Weighing Display XK3
6.6.2017

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
2
22
2
Content
1
Introduction ..................................................................................................... 3
2
Scope of deliver ............................................................................................ 3
3
Intended use ................................................................................................... 3
4
Securit ........................................................................................................... 4
4.1
Safet Instructions for the Bu er .................................................................. 4
4.2
Safet instructions for the operator .............................................................. 4
4.3
Residual Hazards ......................................................................................... 5
5
Technical specifications .................................................................................. 5
6
Getting started ................................................................................................ 6
6.1
Connecting the load cells ............................................................................ 6
6.2
Connecting the power suppl ...................................................................... 7
7
Weighing ......................................................................................................... 7
7.1
Turning on the weighing displa .................................................................. 7
7.2
Zeroing ......................................................................................................... 7
7.3
Standard weighing procedure ..................................................................... 7
7.4
Weighing with Tare function ......................................................................... 8
7.5
Weight summation ....................................................................................... 8
7.6
Animal weighing mode .............................................................................. 10
8
Parameter ...................................................................................................... 11
9
Calibration ..................................................................................................... 13
9.1
Performing a calibration ............................................................................. 13
9.2
Calibration parameters .............................................................................. 14
10
RS232 Interface .......................................................................................... 15
10.1
Connection pin-out ................................................................................. 15
10.2
Configuration ........................................................................................... 16
11
Troubleshooting ......................................................................................... 17
12
Warrant ..................................................................................................... 18
13
Disposal ..................................................................................................... 18
14
Declaration of Conformit .......................................................................... 19
15
Imprint ........................................................................................................ 20

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
3
33
3
1Introduction
Thank ou for choosing this AGRETO weighing displa . You have just
purchased a robust appliance for ever da use.
Please read this manual carefull before putting the weighing displa to use.
As in common parlance, the word 'load' is used instead of 'mass' in this user
manual.
Scope of delivery
The AGRETO Weighing Displa HD1 consists of:
The weighing displa itself
Brackets for wall and table mounting
This user manual
3Intended use
The AGRETO weighing indicator XK3 is intended to be use in dr locations. The
protection class is IP63.
The displa can be connected to most of the common load cells, weighing
platforms or other weighing devices.
The AGRETO XK3 isn't officiall calibratable and therefore not authorized to
determine weights for legal transactions.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
4
44
4
4Security
4.1 Safety Instructions for the Buyer
Important!
Make sure that each person who works for the first time with the
AGRETO XK3 Weighing indicator, has read and understood this
manual.
4. Safety instructions for the operator
DANGER!
The AGRETO XK3 Weighing indicator ma onl be operated b
persons who are familiar with the operation of the device.
PRECAUTION!
Keep the work area clean! Soiled areas contributes to accidents.
ATTENTION!
Repairs and other technical interventions on the device ma onl
be performed b qualified personnel. There is a danger of electric
shock.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
5
55
5
4.3 Residual Hazards
Working with the device residual risks ma arise for persons and objects that
cannot be prevented b design or technical protection measures.
WARNING!
The AGRETO Weighing indicator XK3 must not be operated in
explosive enviroment.
5Technical specifications
Size (W/H/D) 280mm / 160mm / 100mm for table mounting
280mm / 150mm / 145mm for wall mounting
Weight: 1.685g
Operationg temperature: -10 bis +40 °C
Maximum load: adjustable
Resolution: adjustable
Unit: choice between kg or lb
Power suppl : AC 85 to 245V, 50 / 60Hz
Accumulator: internal
Accumulator power: DC 6V, 4Ah
Accumulator runtime: ~. 24h (4 load cells without energ saving mode)
Accumulator charging time: ca. 24h
Accurac class: III, n=3000
Input sensitivit : >= 1.5uV/e
Weighing frequenc : 10x per second
Power suppl load cells: DC +5V
No of load cells: 1 to 6 load cells with 350 Ohms in parallel operation

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
6
66
6
6Getting started
6.1 Connecting the load cells
AGRETO weighing scales are supplied with a connection cable that fits in the
weighing displa . In this case, connect the 9-pin D-SUB connector of the cradle
cable to the matching port on the back of the weighing indicator.
To connect to other weighing scales ou use the connection diagram as
explained b the following table:
Calbe connector
Rear view (soldering side) Front view
No
Description
Function
1
EX
-
Power suppl
-
2
FB
-
Feed Back
-
3
4
5
SHI
Shield
6
EX +
Power suppl +
7
FB +
Feed Back +
8
SI
-
Signal
-
9
SI +
Signal +
If ou have load cells without FeedBack lines PINs 1 and 2 and the PINs 6 and
7 are to be connected.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
7
77
7
6. Connecting the power supply
Connect the small round plug of the power cord into the socket provided on the
back of the displa and plug the power adapter into the power outlet.
The displa can also be used with the built-in batter . Charge the batter
completel before the first use definitel on.
7Weighing
7.1 Turning on the weighing display
Press the [
] button. The weighing displa will now run a self-test. The displa
is read for use when the weight readout appears.
In standard mode the displa isn't put to zero, but shows the actual load, based
on the null position that was last used.
NOTE: Calibration parameter 3 allows ou to configure if and up to what load
the displa automaticall reverts to the zero position during start-up.
7. Zeroing
With the [
0
00
0
] button the displa 's zero position is reset. Use this function
before ever weighing if the displa isn't set to zero.
If the displa is zero the LED (Zero) lights.
NOTE: Calibration parameter 2 allows you to configure the range for manual zero
positioning.
7.3 Standard weighing procedure
Make sure that the displa is set to zero.
Put the weighing object on the scale.
Wait until the displa shows a stable value or until the LED () lights.
Read the weighing result.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
8
88
8
7.4 Weighing with Tare function
When ou'd like to weigh an object in a container or package, the weight of the
empt container can be automaticall subtracted without changing the zero
position, b using the tare function.
Make sure the displa is set to zero.
Put the empt container on the scales.
Wait until the displa shows a stable value, or until the LED () lights.
Press the [ Tare ] button. The displa goes back to zero and the LED (Net)
lights.
Now put the weighing object in the container.
Wait until the displa shows a stable value and until the LED () lights.
Read the weighing result. This is the net weight of the object without
container.
If ou would like to weigh several objects in the same container, ou can
put them on the scales one after the other. As long as the NET – LED ist
lighting, the previousl measured tare will be subtracted and onl the net
weight shown.
To end the tare function ou take the load from the scales and press the [
Tare ] button again.
7.5 Weight summation
Do the following if ou would like to perform several weighings and add up all
the loads:
Make sure the displa is set to zero.
Put the weighing object on the scales.
Waid until the displa shows a stable value and the LED () lights.
Read the weighing result.
Shortl press the [ ∑ ] button. The displa will show the sum of the objects
weighed so far, followed b the amount of weighed objects so far (n 0001),
after which it returns to the normal weighing mode. The LED ( ∑ ) lights up
as long as the sum and amount of weighed objects are displa ed.
Remove the first load from the scales and introduce the next load.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
9
99
9
Shortl press the [ ∑ ] button again. Again, the displa shows the sum of
the objects weighed so far, followed b the amount of weighed objects so
far (n 0002) after which it returns to the normal weighing mode.
Repeat this procedure with all weighing objects.
TTENTION: The summation function will only start after a load of at least 5
increments (for instance: for scales with a 1 kg resolution the summation
function starts at a load of 5 kg)
Displa ing the sum
Displa ing the sumDispla ing the sum
Displa ing the sum
To displa the sum of weighed loads permanentl press the [Σ] ke and keep it
pressed until a beep sounds. If ou release the button the sum of the weights is
displa ed and the two LEDs (Fn) and (Σ) light.
While the sum is displa ed, ou can use the [
] button to switch to the
amount of weighed objects. B pressing the [
] button again ou return to the
normal weighing mode. The sum remains stored, so ou can add additional
weighings.
Deleting the sum
Deleting the sumDeleting the sum
Deleting the sum
Press the [Σ] ke and keep it pressed until a beep sounds. If ou release
the button the sum of the weights is displa ed and the two LEDs (Fn) and
(Σ) light (as above).
Press the button [ ], the displa shows „CLEAR“.
Press the [ ] button to confirm the deletion. The sum and amount are set
to 0 again, and the displa reverts to the normal weighing mode
Press the [ Fn ] button to cancel the deletion.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
10
1010
10
7.6 Animal weighing mode
If ou'd like to weigh restless animals or unstable loads, ou can use the animal
weighing mode. Take the following steps:
Press the [ Fn
FnFn
Fn ] ke shortl to activate animal weighing mode. The displa
shows “ON” for a short time.
Make sure that the displa is set to zero.
Put the weighing object on the scale.
If the weight is in the range r for the time t the average of this time is
calculated, shown and freezed on the displa until the weight is out of the
range. The red point above the “Fn” is illuminated.
Example: Put an animale on the scale, the weight is going up and down. If
the weight is in a range of 20 kg for 3 seconds, the average weight of this 3
seconds is calculated and displa ed. Now ou can take the weight. When
the animal goes awa from the scale the range is exceeded and the scale
is showing the actual weight again.
The parameters r (range) and t (time) can be adjusted.
To turn off the animal weighing mode press the [ Fn
FnFn
Fn ] ke shortl . The
displa shows “OFF” for a short time.
C UTION: The animal weighing mode is only working if the [ Fn
FnFn
Fn ] key is
assigned with the function NL.
C UTION: The animal weighing mode is started only if the weight is above the
minimal weight which is set in the parameter LO.
C UTION: If you press the [ Fn
FnFn
Fn ] button too long, parameter configuration will
start up instead of animal weighing mode.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
11
1111
11
8Parameter
The Weighing Displa HD1 has several configurable parameters that influence
the wa the s stem functions. Normall these parameters have been pre-
configured correctl and need onl be altered in special circumstances.
Take the following steps to start parameter configuration:
To enter the parameter menu press and hold down the [Fn] ke until a
signal sounds
Pressing the [ ] button confirms the entr and returns to the next
parameter. After the last parameter the parameter menu is closed and the
displa returns again in weighing mode.
The [ ] button allows ou to select the desired parameter value.
The [ ] button allows ou to switch between digits for multi-digit entries.
The parameters are described in the following table.
Parameter
Nr
Description
Displa
Comment
1
Function of the [ Fn ]
button
Fn **
Lb = switch between kg and lb
ANL = animal weighing mode
function (standard)
-- = no function
2
Power Save Mode
PS **
OFF = no power save mode
(standard)
oN = power save mode after 5
minutes without change in weight
onP = turn off the displa after 5
minutes without change in weight
3
Baudrate RS232
Interface
Br ****
600
1200
2400 (standard)
4800
9600

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
12
1212
12
4
Communication mode
RS232 interface
Co *
1 (standard) see chapter: RS232
interface
5
Target weight range HI
H*****
Is the weight displa higher than
the value set here, then the (LED
HI) lights.
Default value: 75% of the rated
load of the load cells (3000 in a
displa without weighing
technolog )
6
Target weight range LO
L*****
Is the weight displa
low
er than
the value set here, then the (LED
LO) lights.
Default value: 0
7
Range for animal
weighing mode
r *****
standard: 20.0
8
Time for animal
weighing mode
t *
standard: 3

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
13
1313
13
9Calibration
If ou bought the weighing displa together with AGRETO weighing scales, the
displa is alread full calibrated and checked.
Calibration is onl needed:
If ou didn't bu the weighing displa together with AGRETO weighing
scales.
If ou use the scales for a special construction, for example when ou want
to retrofit mechanical scales.
If the location of the weighing s stem is outside of the geographical area
between 45 and 52 degrees latitude.
If the location of the weighing s stem is at an altitude higher than 1000 m
above sea level.
If for whatever reason ou do not succeed in using the scales in the
prescribed mounting position.
9.1 Performing a calibration
ATTENTION: A calibration determines the accurac of the scales. A calibration
ATTENTION: A calibration determines the accurac of the scales. A calibration ATTENTION: A calibration determines the accurac of the scales. A calibration
ATTENTION: A calibration determines the accurac of the scales. A calibration
cannot be undone!
cannot be undone!cannot be undone!
cannot be undone!
To perform a calibration ou need a reference load that is as close as possible
to the nominal load. It should be at least 20% of the nominal load of the load
cells. This means that scales with a nominal load of 4000 kg need to be
calibrated with at least 800 kg.
Take the following steps to start the calibration procedure:
For entr into the calibration, remove the protective cover on the back and
press the inner button until the displa shows the word CAL.
Pressing the button [ ] confirms the entr and returns to the next
parameter. After the last parameter the parameter menu is closed and the
displa returns into weighing mode
Press the [ ] the desired value or the desired setting can be selected
within a parameter.
The [ ] button allows ou to switch between digits for multi-digit entries
All the steps of the calibration process are described in the following table.
The must be performed in this order.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
14
1414
14
Step
Nr
Description
Displa
Comment
1
Division
E **
01 02 05 10 20 50
Depending on the weighing scales
2
Amount of decimal
places
dC ****
0 0.0 0.00 0.000
Depending on the weighing scales
3
Nominal load
F *****
Nominal load of the load cells
4
Zero position
noLoAd
No load on the scales
5
Calibrating load
AdLoAd
******
Introduce the calibrating load and
enter the weight of the calibrating load
9. Calibration parameters
ATTENTION: These parameters change the characteristics of the weighing
ATTENTION: These parameters change the characteristics of the weighing ATTENTION: These parameters change the characteristics of the weighing
ATTENTION: These parameters change the characteristics of the weighing
displa . Improper use can cause a distortion of weighing results.
displa . Improper use can cause a distortion of weighing results.displa . Improper use can cause a distortion of weighing results.
displa . Improper use can cause a distortion of weighing results.
Take the following steps to enter the calibration settings:
For entr into the parameters remove the small cover on the back and
press the inner button until the displa shows the word CAL. Then press
successivel the [ ] and [ ] ke s.
Press the [ ] confirms the entr and returns to the next parameter. After
the last parameter the parameter menu is closed and the displa returns
into the weighing mode.
The[ ] button allows ou to select the desired parameter value.
The [ ] button allows ou to switch between digits for multi-digit entries.
The parameters are described in the following table.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
15
1515
15
Parameter
Nr
Description
Displa
Comment
1
Zero point stabilisation
Zot **
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
division units
Standard setting: 2.0
2
Range for manual
zero positioning
Nt ***
0 2 4 10 20 100 percent of
nominal load can be zero
positioned
Standard setting: 100%
3
Range for automatic
zero positioning
At
--
0 2 4 10 20 100 percent of
nominal load can be automaticall
zero positioned
Standard setting: --
4
Responsiveness
FL ***
Stb: slow responsiveness
Sen: fast responsiveness
(standard)
10 RS 3 Interface
The weighing indicator has a serial interface for controlling an additional
displa , a printer, or to communicate with a PLC or a PC.
10.1 Connection pin-out
Connector view displa side (soldering side of connector)
5
55
5
4
44
4
3
33
3
2
22
2
1
11
1
1
RX
2TX
3GND
4Input big displa
5Output big displa

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
16
1616
16
10. Configuration
With the parameter 3, the baud rate is set. The other interface parameters of the
RS232 interface can be used b default.
The parameter 4, the operation of the interface is defined.
1: Automatic
1: Automatic 1: Automatic
1: Automatic output of the net weight without a unit in toppled sequence of
output of the net weight without a unit in toppled sequence of output of the net weight without a unit in toppled sequence of
output of the net weight without a unit in toppled sequence of
digits, 8 digits
digits, 8 digitsdigits, 8 digits
digits, 8 digits
i.e.: 23,45 kg -> 54.3200
-23,45 kg -> 54.320-
2: Automatic output of the gross weight without a unit in toppled sequence of
2: Automatic output of the gross weight without a unit in toppled sequence of 2: Automatic output of the gross weight without a unit in toppled sequence of
2: Automatic output of the gross weight without a unit in toppled sequence of
digits, 8 digits
digits, 8 digitsdigits, 8 digits
digits, 8 digits
i.e.: 23,45 kg -> 54.3200
-23,45 kg -> 54.320-
3: Automatic output of the net weight with unit, 14
3: Automatic output of the net weight with unit, 143: Automatic output of the net weight with unit, 14
3: Automatic output of the net weight with unit, 14-
--
-digit
digitdigit
digit
i.e.: 23,45 kg -> 0023.45 (kg) + HEX(0D) + HEX(0A)
4: Automatic output of the gross weight with unit, 14
4: Automatic output of the gross weight with unit, 144: Automatic output of the gross weight with unit, 14
4: Automatic output of the gross weight with unit, 14-
--
-digit
digitdigit
digit
i.e.: 23,45 kg -> 0023.45 (kg) + HEX(0D) + HEX(0A)
5: command mode, issue
5: command mode, issue 5: command mode, issue
5: command mode, issue on the request
on the requeston the request
on the request
Gross weight request
command: HEX(02)+“A“+“HEX(03), answer: GW:0023.45 (kg)
Net weight request
command HEX(02)+“B“+“HEX(03): answer: NW:0013.45 (kg)
Tare weight request
command HEX(02)+“C“+“HEX(03): answer: TW:0010.00 (kg)
Trigger zero position
command HEX(02)+“D“+“HEX(03): answer: D
Trigger Tare funktion
command HEX(02)+“E“+“HEX(03): answer: E
6: Output of the weight when pressing the SUM function on the displa , for
6: Output of the weight when pressing the SUM function on the displa , for 6: Output of the weight when pressing the SUM function on the displa , for
6: Output of the weight when pressing the SUM function on the displa , for
connecting a printer directl
connecting a printer directlconnecting a printer directl
connecting a printer directl

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
17
1717
17
11 Troubleshooting
The following error messages can appear on the displa screen:
Displa
Description
Solution
Err 01
Range for zero
positioning has been
exceeded
Reduce the load on the scales or set
calibration parameter 2 to a higher value.
Err 02
Load
for this function
is too low
Some functions are onl available for loads of
5 increments onwards.
Err 03
Overloaded
Reduce the load on the scales.
Err 04
Weight not stable
The weight isn't stable during calibration. The
calibration procedure can't be performed.
Err 05
Weight is too low
A higher load must be used for the calibration
procedure. The calibration procedure can't be
performed.
Err 06
Weight not stable
For some functions the weight must be stable.

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
18
1818
18
1 Warranty
Over and above statutor warrant for AGRETO weighing indicator XK3
following warrant provisions appl :
The AGRETO electronics GmbH guarantees the function and repairs or
replaces all the parts that have a material or manufacturing damage within
the warrant period.
Warrant services will be performed b the AGRETO electronics GmbH.
The decision on the existence of a warrant claim is sole responsibilit of
the AGRETO electronics GmbH.
The warrant period begins with the first accounting to an end customer
and ends 5 ears from this date of invoice.
Prerequisite for warrant service are the presentation of the original invoice
and compliance with all elements of this instruction manual.
Excluded from warrant are wear, normal wear and tear, damage due to
misuse, negligence or accident.
When processing a warrant claim transport costs incurred will be charged
to the bu er.
13 Disposal
Dispose the product in the definitive shutdown or parts of
environmentall friendl (metal to the respective metal scrap, plastic
to plastic waste, etc. - Do not dispose as household waste!)
Detailed information can be found in Directive 2002/96/EC

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
19
1919
19
14 Declaration of Conformity
EC Declaration of Conformit
For the following named product
AGRETO XK3 Weighing Indicator
This is to confirm that it complies with the essential protection requirements of Council
Directive on the approximation of the laws of Member States relating to electromagnetic
compatibilit (2004/108/EC) and Low Voltage Directive (2006/95/EG).
For the evaluation the following standards were applied:
EN 61010-1:2001, EN 61326-1:2006, EN 61000-3-3:2008, EN 61000-3-3:2008,
EN 61326-1:2006
This explanation is given b the manufacturer
AGRETO electronics GmbH
Pommersdorf 11
3820 Raabs
Submitted b :
Anton Eder
Business Manager
Pommersdorf 12.03.2014
___________________ ________________ ______________________
legall binding signature

AGRETO Weighing Display XK3
©
© ©
© AGRETO
AGRETOAGRETO
AGRETO
electronics GmbH
electronics GmbH electronics GmbH
electronics GmbH
20
2020
20
15 Imprint
All information, specifications and images are correct according to the status in
2017, and subject to technical adjustments or changes in design.
Despite careful treatment and examination of the contents, no warrant is made
with respect to information in this user manual. An liabilit of the author is
excluded.
Cop right © 2017, AGRETO electronics GmbH
AGRETO electronics GmbH
Pommersdorf 11
A-3820 Raabs
Tel.: +43 2846 620 0
Fax: +43 2846 620 19
Mail: office@agreto.com
Internet: www.agreto.com
Other manuals for XK3
1
Table of contents
Other Agreto Accessories manuals
Popular Accessories manuals by other brands

Sony
Sony CP-V10 operating instructions

Just Mobile
Just Mobile Gum user manual

MICRO-EPSILON
MICRO-EPSILON scanCONTROL 2900 Assembly instructions

Bin Master
Bin Master NCR-84 operating instructions

MTS Sensors
MTS Sensors Temposonics T Series Operation manual

OJ Electronics
OJ Electronics MICROLINE OTD2 instructions