Agrowtek SXC User manual

1© Agrowtek Inc. | www.agrowtek.com
Technology to Help You Grow
AGROWtEK
Power 24Vdc, ~5W
Max Cable Distance 1000ft
Aspirator 6cfm Fan with Foam Filter
Temperature Range -20 - 60°C
Temperature Accuracy ±0.2°C typical
±0.4°C maximum
Humidity Range 0-100% RH (non condensing)
Humidity Accuracy ±2% 0-80% typical
±4% maximum
Light Irradiance Range 0 - 1000W/m2
Light Accuracy ±10%
CO2 Range 0-2000ppm
(10.000ppm Modbus)
CO2 Accuracy ±50ppm + 3% of reading
4-20mA DAC Resolution 12 bit, 0.005mA
Interface GrowNET, MODBUS or WiFi
Specications
Shown with optional WiFi
Climate Sensor & Data Logger
Contents
Installation Instructions 2
Connection to GC-Pro or GC-ProXL Controller 3
Sensor Mapping 3
Connection to USB AgrowLINK 4
Connection to 4-20mA Outputs 4
Connection to MODBUS RTU 5
HX8 8-Port Hubs 5
Serial Speed & Format 5
Supported Commands 6
Register Types 6
Sensor Value Registers 6
Calibration Registers 6
MODBUS Register Map 7
CO2 ppm Sensor Upgrade 8
Maintenance & Service 9
Cleaning 9
Fan Filter 9
Storage and Disposal 10
Warranty 10
INSTRUCTION MANUAL
SXC

2© Agrowtek Inc. | www.agrowtek.com
Techno logy to Help You Grow
AGROWtEK
U.S.A.
MADE IN
© 2016 Agrowtek Inc.
www.agrowtek.com
GrowControl
DigiClimate Canopy Sensor
TM
TEMP RH LIGHTC O2
if equipped
KEEP
FAN
FILTER
CLEAN
Intake Fan
& Filter
Light Sensor
GrowNET/MODBUS Port
RS-485
Power Jack
or Mini-Din
6-pin Analog
Exhaust
Slost
Stainless Steel
Hanging Bracket
WiFi Antenna
if equipped
Wall Mounting
Slots
WiFi AP Mode Reset
Wall mounting slots are provided for installing against a vertical wall surface, or a hanging bracket is avail-
able for conveniently suspending the sensor from a wire or cable in the middle of the environment. Note the
location of the light sensor (top.) Sensor should be installed with the light sensor facing up.
Install in locations with adequate access to the environmental conditions and away from extreme inuences
such as ventilation ducts, doorways, windows or heat generating equipment such as lights and ballasts.
Installation Instructions
Do NOT connect the GrowNET port to Ethernet networks. Disconnect power while making connections to
prevent damage to any components.

3© Agrowtek Inc. | www.agrowtek.com
Sensors with analog output connect to Agrowtek’s GC-Pro and GC-ProXL controllers using the standard
MINI-DIN 6 analog sensor cable. Power is provided to the sensor through this cable.
Plug the cable rmly into the analog port on the sensor and into the desired sensor port inside the GC-Pro/
XL controller. Sensor ports are located on “modules”inside of the controller. Route sensor cables through the
sensor cable slot on the bottom of the controller.
50ft extension cables are available and may be used to extend up to 1000ft distance from the controller.
Connection to GC-Pro or GC-ProXL Controller
Technology to Help You Grow
AGROWtEK
U.S.A.
MADEIN
© 2016 Agrowtek Inc.
www.agrowtek.com
GrowControl
SXC
TM
TEMP RH LIGHT CO2
if equipped
KEEP
FAN
FILTER
CLEAN
Sensor Mapping
Sensors must be “mapped”in the controller so it knows which sensors are connected to the sensor ports.
Each port has four“channels”which must be mapped according to the sensor’s channels.
Controller Channels:
Port 1 = Channels 1-4
Port 2 = Channels 5-8
Port 3 = Channels 9-12
Port 4 = Channels 13-16
Sensor Channels:
Channel A = Temperature
Channel B = Humidity
Channel C = Light
Channel D = Humidity
Example mapping zone 1 climate sensor connected to port#2:
Temperature = 5
Humidity = 6
Light = 7
CO2 = 8 (leave 0 if CO2 sensor is not installed)
© Agrowtek Inc. | www.agrowtek.com
GrowControl
U. S. A.
MADE IN
TM
Cultivation Control System
Technology to Help You Grow
AGROWtEK
GC-PRO
50 ft. Extension Cable(s)
(optional)
15 ft. Sensor Cable
(standard)

4© Agrowtek Inc. | www.agrowtek.com
LX1 USB AgrowLINK connects Agrowtek’s devices to a computer’s USB port for:
Connection to USB AgrowLINK
Technology to Help You Grow
AGROWtEK
U.S.A.
MADE IN
© 2016 Agrowtek Inc.
www.agrowtek.com
GrowControl
SXC
TM
TEMP RH LIGHT CO2
if equipped
KEEP
FAN
FILTER
CLEAN
Technology to Help You Grow
AGROWtEK
U.S.A.
MADE IN www.agrowtek.com
GrowNET
Device/Hub
TM
USB
AgrowLINKTM
LX1 USB to GrowNET™ Bridge
TX
RX
• Firmware Updates
• Calibration
• Conguration
• Data Logging Download
• More
24Vdc 12W
Power Supply
Option 1: Use the LX3 Analog Bridge with Mini-Din 6 analog sensor port connection and removable terminal
block for wire connections. Terminal block includes 24V power terminals and four terminals for the analog
channels. 4-20mA linear outputs correspond to the ranges in the specications table.
Connection to 4-20mA Outputs
24VDC
4-20mA PLC
ANALOG INPUTS
PIN CONNECTION
1 +24VDC
2 GND
3 CH 1 (TEMPERATURE)
4 CH 2 (HUMIDITY)
5 CH 3 (LIGHT)
6 CH 4 (CO2)
Technology to Help You Grow
AGROWtEK
U.S.A.
MADE IN
© 2016 Agrowtek Inc.
www.agrowtek.com
GrowControl
SXC
TM
TEMP RH LIGHT CO2
if equipped
KEEP
FAN
FILTER
CLEAN
Technology to Help You Grow
AGROWtEK
U.S.A.
MADE IN
© 2016 Agrowtek Inc.
www.agrowtek.com
GrowControl
SXC
TM
TEMP RH LIGHT CO2
if equipped
KEEP
FAN
FILTER
CLEAN
MINI-DIN 6
Analog Cable
Option 2: Create a cable for direct connection to a PLC from a Mini-Din 6 cable.
Visit www.agrowtek.com for free software applications.
Standard FTDI drivers automatically install in Windows. GrowNET protocol available for custom software ap-
plications; sample C# code available. See software manual for more information.

5© Agrowtek Inc. | www.agrowtek.com
Technology to Help You Grow
AGROWtEK
U.S.A.
MADE IN
© 2016 Agrowtek Inc.
www.agrowtek.com
GrowControl
SXC
TM
TEMP RH LIGHT CO2
if equipped
KEEP
FAN
FILTER
CLEAN
Connection to MODBUS RTU
Serial Speed & Format
RS-485
Use the LX2 ModLINK to connect MODBUS devices to the GrowNET™ port.
HX8 8-Port Hubs
HX8 GrowNET ™ Hubs allow multiple GrowNET™ sensors, relays and
dosing pumps to be connected to a single LX1 or LX2 interface. Indi-
vidually buered, full-duplex ports for signal integrity. Hubs can be
daisy chained to form a network of up to 247 devices.
Hubs provide up to 1A of power for operating sensors and some re-
lays directly over the GrowNET cable. A DC jack on the hub provides
24Vdc power to the ports from the included 120V wall power supply.
Technology to Help You Grow
AGROWtEK
U.S.A.
MADE IN
© Agrowtek Inc. | www.agrowtek.com
TM
GrowNET 8-Port Hub
GrowControl
TM
8 7 6 5
POWER
12-24Vdc
GrowNET
Upstream
Port
TM
HX8
The default serial data format for the LX2 ModLINK interface is: 19,200 baud, 8-N-1.
Alternate speeds and formats between 9,600 - 115,200 baud may be congured with the free AgrowLINK PC
utility using a LX1 USB AgrowLINK and the cross-over adapter supplied with the LX2 ModLINK.
MODBUS Manual
See MODBUS manual for more information.
LX2 ModLINK™
Technology to Help You Grow
AGROWtEK
U.S.A.
MADE IN www.agrowtek.com
GrowNET
Device/Hub
TM
USB
AgrowLINKTM
LX1 USB to GrowNET™ Bridge
TX
RX
GrowNET
Cross-Over
Adapter
LX1 USB AgrowLINK™
GrowNET™
Cross-Over
Adapter
7 - 24 Vdc
Technology to Help You Grow
AGROWtEK
U.S.A.
MADE IN
www.agrowtek.com
GrowNET
Device/Hub
TM
ModLINK TM
LX2 MODBUS RTU Bridge
+7-24Vdc
GND
A
B
RJ45 CABLE
7 - 24 Vdc
Technology to Help You Grow
AGROWtEK
U.S.A.
MADEIN
©Arowtek Inc. | www.agrowtek.com
GrowNET
Link Port
MODBUS
TM Digital WaterSensor
Logger & Controller
TEMPERATURE CONDUCTIVITYpH O.R.P./ D.O.
GrowControl
TM
pH
Probe
o.r.p./d.o.
Probe
Temp Probe | EC Probe
red blk wht | clr red blk
GPH MNUH/L
72.0
45.2
123
455
°F
%
W/m
ppm
2
Technology to Help You Grow
AGROWtEK
GrowControl
TM
SXE
Environment Sensor
Data Logger
U.S.A.
MADEIN
© Agrowtek Inc.
www.agrowtek.com
WiFi
optional
GrowNET
Link Port
MDOBUSRTU
TM
WiFi
Reset
24Vdc in
4-20mA out
KEEP
FAN
FILTER
CLEAN
GPH MNUH/L
72.0
45.2
123
455
°F
%
W/m
ppm
2
Technology to Help You Grow
AGROWtEK
©2016 Agrowtek Inc. | www.agrowtek.com
RD8
Equipment Control Interface
U.S.A.
MADEIN
DANGER!Risk of electric shock.
Disconnectall power sources before opening cover.
Readmanual before installing or operating.
WiFi
Antenna
Programmable Smart Relays for Automation Control
1 2 3 4 5 6 7 8
AgrowNET
Link Port
TM
STATUS INDICATORS
GrowNET™ Devices
3.3/5Vdc Serial Bus Compatible.
Include required bus terminating resistors per EIA standard.
TX/RX+
TX/RX-
PLC
Technology to Help You Grow
AGROWtEK
U.S.A.
MADE IN
www.agrowtek.com
GrowNET
Device/Hub
TM
ModLINK TM
LX2 MODBUS RTU Bridge
+7-24Vdc
GND
A
B
Technology to Help You Grow
AGROWtEK
U.S.A.
MADEIN
© Agrowtek Inc. | www.agrowtek.com
GrowNET™8-Port Hub
GrowControl™
1 2 3 4
8 7 6 5
12-24Vdc
GrowNET
Upstream
Port
TM
HX8
power
RS-485

6© Agrowtek Inc. | www.agrowtek.com
Calibration registers are 16-bit signed integers for the purpose of calibrating the sensor values or analog out-
put channels. Calibration may be achieved by writing the desired calibrated value to the associated register.
Writing to the calibration registers automatically invokes the calibration routine for that register.
Oset Calibration
Oset, or zero calibration, is an arithmatic positive or negative correction to the sensor reading and is the
only type of sensor calibration available on climate/environmental sensors.
To perform a sensor oset calibration, simply write the corrected sensor value to the oset calibration reg-
siter (taking into account the integer scale as shown above.)
For example: to set the temperature to a calibrated value of 25°C, write the value“2500.”
Analog Calibration
Analog output calibration sends a positive or negative oset to the respective output channel’s digital to
analog converter (DAC.) The DAC has a resolution of 0.005mA/bit.
±1 calibration bit = ±0.005mA adjustment
For example: to shift the analog output up by 0.1mA, set the analog oest value to +20. ( 0.1 / 0.005 = 20)
Sensor # Type Integer Scale Range
1 Temperature x100 -2000 - 6000 (-20 - 60°C)
2 Humidity x10 0 - 1000 (0 - 100%)
3 Light x1 0 - 1000 W/m2
4CO2 x1 0 - 2000 ppm
For example: an integer temperature value of 2417 is equal to a temperature reading of 24.17°C.
Sensor values are available in integer or oating point formats depending on the register requested (see
map.)
Sensor Value Registers
Calibration Registers
0x03 Read Multiple Registers
0x06 Write Single Register
0x10 Write Multiple Register
Supported Commands
All registers are 16 bits wide with addresses using the standard MODICON protocol. Floating point values
use the standard IEEE 32-bit format occupying two contiguous 16 bit registers. ASCII values are stored with
two characters (bytes) per register in hexadecimal format.
Register Types

7© Agrowtek Inc. | www.agrowtek.com
MODBUS Register Map
Parameter Function Type Scale Access Address
Device Address Slave Address Value, 1-247 8 bit R/W 40001
Serial# Serial Number ASCII 8 Char R 40004
DOM Date of Manufacture ASCII 8 Char R 40008
HW Version Hardware Version ASCII 8 Char R 40012
FW Version Firmware Version ASCII 8 Char R 40016
Sensor 1 Value Sensor output Signed Int 16 bit R 40101
Sensor 2 Value Sensor output Signed Int 16 bit R 40102
Sensor 3 Value Sensor output Signed Int 16 bit R 40103
Sensor 4 Value Sensor output Signed Int 16 bit R 40104
Sensor 1 Value Sensor output Float 32-bit R 40201
Sensor 2 Value Sensor output Float 32-bit R 40203
Sensor 3 Value Sensor output Float 32-bit R 40205
Sensor 4 Value Sensor output Float 32-bit R 40207
Sensor 1 Oset Cal Calibration Input Signed Int 16 bit W 41101
Sensor 2 Oset Cal Calibration Input Signed Int 16 bit W 41102
Sensor 3 Oset Cal Calibration Input Signed Int 16 bit W 41103
Sensor 4 Oset Cal Calibration Input Signed Int 16 bit W 41104
Sensor 1 Analog Cal Calibration Input Signed Int 16 bit W 41301
Sensor 2 Analog Cal Calibration Input Signed Int 16 bit W 41302
Sensor 3 Analog Cal Calibration Input Signed Int 16 bit W 41303
Sensor 4 Analog Cal Calibration Input Signed Int 16 bit W 41304

8© Agrowtek Inc. | www.agrowtek.com
CO2 ppm Sensor Upgrade
The SXC sensor may be upgrade to sense and control CO2 ppm with a precision NDIR type CO2 sensor.
1. Disconnect cables from the sensor.
2. Remove the hanging bracket (1).
3. Take note the orientation of the light sensor on the cover.
4. Remove the two cover screws (2) and lift o the cover.
5. Locate the CO2 headers on the circuit board.
6. Position and install the CO2 sensor module (3) ensuring the sensor is oriented with the correct pin head-
ers. One header is 4-pins and the other is 5-pins.
Installing the sensor backwards will damage the CO2 module.
7. Re-install the top cover and re-connect cables.
Note the light sensor orientation is correct and not backwards.
8. Check to ensure the CO2 reading is now working.
Note correct pin alignment.
1
2
3
5 pins
4 pins
CO2 Sensor
Module
Light
Sensor
CO2 Sensor
Headers

9© Agrowtek Inc. | www.agrowtek.com
Exterior and label surfaces may be wiped with a damp cloth wish mild dish detergent, then wiped dry.
Avoid spraying the sensor with chemicals or water spray.
Maintenance & Service
Cleaning
Sensors require periodic maintenance to ensure proper performance.
Fan Filter
2
1
3
The fan air lter should be periodically removed for cleaning.
It is NOT necessary to remove the fan.
1. Pry the retaining grate (1) out of the base (3) using a small at blade eye-glass screwdriver.
2. Remove the foam lter (2) and replace, or clean with mild dish detergent and water, then pat dry.
3. Check for proper fan operation while the lter is removed.
If fan is not spinning or is making noise, replace the fan.
4. Re-install the foam lter (2) and grate (1) into the base (3) gently snapping the grate back into place.

10 © Agrowtek Inc. | www.agrowtek.com
Agrowtek Inc. warrants that all manufactured products are, to the best of its knowledge, free of defective
material and workmanship and warrants this product for 1 year from the date of purchase. This warranty
is extended to the original purchaser from the date of receipt. This warranty does not cover damages from
abuse, accidental breakage, or units that have been modied, altered, or installed in a manner other than
that which is specied in the installation instructions. Agrowtek Inc. must be contacted prior to return ship-
ment for a return authorization. No returns will be accepted without a return authorization. This warranty
is applicable only to products that have been properly stored, installed, and maintained per the installation
and operation manual and used for their intended purpose. This limited warranty does not cover products
installed in or operated under unusual conditions or environments including, but not limited to, high hu-
midity or high temperature conditions. The products which have been claimed and comply with the afore-
mentioned restrictions shall be replaced or repaired at the sole discretion of the Agrowtek Inc. at no charge.
This warranty is provided in lieu of all other warranty provisions, express or implied. It is including but not
limited to any implied warranty of tness or merchantability for a particular purpose and is limited to the
Warranty Period. In no event or circumstance shall Agrowtek Inc. be liable to any third party or the claimant
for damages in excess of the price paid for the product, or for any loss of use, inconvenience, commercial
loss, loss of time, lost prots or savings or any other incidental, consequential or special damages arising out
of the use of, or inability to use, the product. This disclaimer is made to the fullest extent allowed by law or
regulation and is specically made to specify that the liability of Agrowtek Inc. under this limited warranty,
or any claimed extension thereof, shall be to replace or repair the Product or refund the price paid for the
Product.
Warranty
Storage and Disposal
Storage
Store equipment in a clean, dry environment with ambient temperature between10-50°C.
Disposal
This indsutrial control equipment may contain traces of lead or other metals and environmental contami-
nants and must not be discarded as unsorted municipal waste, but must be collected separately for the
purpose of treatment, recovery and environmentally sound disposal. Wash hands after handling internal
components or PCB’s.
Other manuals for SXC
1
This manual suits for next models
1
Table of contents
Other Agrowtek Data Logger manuals
Popular Data Logger manuals by other brands

SLOPE INDICATOR
SLOPE INDICATOR GTecLink manual

Campbell
Campbell 21X Operator's manual

MadgeTech
MadgeTech HITEMP140-PT Product user guide

optel
optel OPBOX-2.1 Description and manual

Eddyfi Technologies
Eddyfi Technologies TSC Amigo2 Getting started

Measurement Computing
Measurement Computing WebDAQ 504 user guide