AGS Merlin 1000Si User manual

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 1
Merlin 1000Si
Gas Utility Isolation Controller
Installation & Operation Manual
Please read this manual carefully and retain for future use.
The Merlin 1000Si is designed as an isolation controller that controls fire pit gas through a
solenoid valve and interrupts the line voltage to the panel with a digital, programmable timer
providing seven day automatic control.

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 2
Contents
INSTALLATION ...........................................................................................3
Planning........................................................................................................................... 3
Fixing - Mounting............................................................................................................ 3
Typical Installation Arrangement ............................................................................... 4
Terminal Connections................................................................................................... 4
Switch Settings................................................................................................................ 6
Specification .................................................................................................................. 8
OPERATION ................................................................................................9
First Power Up ................................................................................................................. 9
Emergency Shut Off Button ......................................................................................... 9
LED Indicators................................................................................................................. 9
Servicing & General Maintenance .......................................................................... 11
Bump Testing ................................................................................................................ 11
IMPORTANT WARNING STATEMENTS ...................................................12
Manufacturer’s Warranty........................................................................................... 12
Installation Details........................................................................................................ 16

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 3
INSTALLATION
Planning
The Merlin 1000Si is to be used an isolation utility controller that controls the fire pit gas supply
through a solenoid valve and interrupts the line voltage to the panel with a digital
programmable timer providing 7 day automatic control. If either the 1000Si controller is in alarm
condition or any of the remote EPO buttons alarm the gas solenoid valve will close and will only
re-energize once the fault has been cleared. For additional fire pits, a separate digital
programmable timer will provide 7 day automatic control over a single or multiple gas solenoid
valves.
The Merlin 1000Si can work in conjunction with carbon dioxide, natural gas, carbon monoxide
and LPG sensors. The Merlin 1000Si also has a built in “timeout” facility which will automatically
shut off the gas solenoid valve at the end of a specific time period, this time period can be
adjusted to 2, 5, 8 hours or can be overridden if required.
Placing the panel at eye level allows for optimum monitoring of LED Indicators.
Fixing - Mounting
Unpack all the parts!
1. Carefully remove the front cover from the unit by unscrewing the four bolts located at each
corner. To do this –use the socket wrench provided.
2. Mark the four screw holes located on the back of the enclosure to the wall. Ensure the wall
surface is flat to prevent base distortion.
3. After executing the mounting and the connections –replace the front cover and insert the
security caps over the four bolts.
A flush mount kit is available, comprising of a mounting bracket and decorative surround strip.
Contact your supplier for more information.
Please refer to your detector manual for important information regarding coverage,
location and positioning including areas and conditions to avoid.
Be careful when creating access for cables –Damage to boards will void any warranty.
Carefully remove the circuit board before drilling cable entry holes.

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 4
Typical Installation Arrangement
Terminal Connections
1. POWER / LINE IN
110-120V AC Power should be supplied to the [POWER / LINE IN] terminal and fused at 3A.
On connecting the mains supply to the panel the power LED indicator will light up –this is
located on the front cover (American Gas Safety Logo).
2. GAS SOLENOID VALVE OUTPUT
100-120V AC electrical power supplied from the [VALVE OUT] connector using a 3 core cable
can be connected to a gas solenoid valve which can shut the gas supply on alarm status.
Refer to your valve manual for more information and wiring!

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 5
3. BMS OUTPUT
Connections are available on the board for Building Management Systems.
[NO Normally Open] [COM Common] [NC Normally Closed]
These are volt free connections.
This is a relay that changes state in alarm or when the gas is on/off and can be used in
conjunction with the 12V DC output and other external relays that affect other devices and
controls such as purge fans and audible alarms etc.
See section; Switch Settings - for BMS options
4. EM REMOTE
Connections for remote emergency shut-off or stop buttons is detailed on the circuit board as
[EM REMOTE]. This is linked out as a factory setting.
Remote emergency shut-off buttons should be volt free and wired to the Merlin 1000Si using a
plenum security cable, white, 18/2 (18AWG 2 conductor), stranded, CMP or similar.
5. GAS DETECTOR
Connections can be made for a Merlin gas detector (LPG, NG, CO or Hydrogen).
If no detector is being used leave the factory fitted link in.
A wiring example is shown.
Refer to your gas detector manual for further information.
6. FAN SWITCHES
This terminal switches when the key is turned on and off.
This can be connected to a fan switch (supplied separately) which can provide power to fans
when the control panel is switched on.
7. CO2 MONITOR
This terminal can be used to connect a Merlin CO2monitor to shut off the system in the event of
a high concentration of CO2.
If no CO2 monitor is connected, the panel will ‘beep’ upon power up and the CO2 LED will
flash 3 times to indicate that this terminal has been disabled.
An external power supply is required.
Refer to your CO2monitor manual for further information.
8. 12V DC
This is a power output for external auxiliary devices when there is power at the panel and can
be used to create a relay switch with the BMS relay output.
Max output: 50mA

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 6
Switch Settings
There are various dip-switches on the front circuit board that can be adjusted to configure your
system as per the following.
Auto Reset
There is a switch located on the circuit board labelled [AUTO RESET].
OFF
When power is restored after the power cut/ loss, the panel has to be
restarted manually. (Default)
ON
This will instruct the system to restart automatically when power is
restored after power cut/loss.
Building Management System Integration
There is a dip-switch located on the circuit board labelled [BMS SEL].
The panel can be integrated with a BMS to make or break a circuit when the gas is either on or
off, (valve open or valve closed). This will tell the BMS whether or not power is being
sent to the solenoid valve.
OFF
Signals the BMS when gas is on or gas is off. (Default)
ON
Signals the BMS on a fault, i.e. high gas levels detected, emergency
shut-off activated, etc.
Fan Switch Integration
There is the facility to connect a Fan Switch.
A fan switch (Merlin FS1 or FS2 - sold separately) provides the facility to turn on fan(s) when the
1000Si panel is switched on and removes power to fan(s) when the switched off.
There is a switch located on the circuit board labelled [EM SEL].
OFF
Instructs the system to shut down fan(s) and gas supply upon
activation of emergency shut off button(s). (Default)
ON
Instructs the system to leave the fans on and shut off the gas supply
only upon activation of emergency shut off button(s).
Note: This option is not available if a Fan Switch is not installed.

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 7
Fire Panel Integration
The Merlin 1000Si can be integrated with a fire alarm to close the gas supply automatically in
the event of a fire. The volt free fire alarm signal can be wired in series with any remote
emergency shut off buttons.
If there are no remote emergency shut off buttons being installed, wire this directly to the
terminal marked [EM REMOTE].
Auto Shut-Down - Timeout Period
The system has an auto-shut down feature after a selected time.
There are two switches located on the circuit board labelled [TIME1] & [TIME2].
These can be configured to select the required timeout/ shut-down period.
TIME 1
TIME 2
Timeout Period
OFF
OFF
2 Hours (Default)
ON
OFF
4 Hours
OFF
ON
8 Hours
ON
ON
Disabled
Note: Upon timeout the gas supply will be turned off

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 8
Specification
Model:
1000Si
Visual Indication
LED
Mains Electrical Power Input
100-120VAC
Gas Solenoid Valve Output
100-120VAC
Current Consumption
12W max or 50mA @ 120VAC
Internal Fuse
3.15A
Operating Temperature
32 –104°F 0-95%RH Non-Condensing
Audible Alarm Buzzer dB
65 dB (300mm distance in quiet conditions)
Internet connection
N/A
Housing Material
Polylac PA-765
Flame Rating
UL 94
Approvals
CE, RoHS
O/All Dimensions (H x W x D) mm / inch
7.08 x 10 x 3.03”

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 9
OPERATION
First Power Up
On connecting mains power, an LED on the front of the panel (AGS Logo) will illuminate red.
Turn the key switch to on position.
Turn the key switch to the off position to turn the panel off.
Emergency Shut Off Button
The emergency shut off button is located on the front of the panel.
There is also a facility for remote shut off buttons to be wired in series on the circuit board.
The emergency shut off button(s) will cut off the gas supply and electrics only when activated.
To reinstate the system, the emergency shut off button(s) will need to be reset and the panel
restarted.
LED Indicators
Gas On
When the key switch is turned on, the Merlin 1000Si will check the installation for gas leaks. If gas
proving is successful, the gas valve will open and the ‘Gas On’ LED will illuminate.
ON = Gas On
OFF = Gas Off
Testing
Under normal working conditions this LED is off.
This feature is disabled.

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 10
Test Fail
Under normal working conditions this LED is off.
This feature is disabled.
Pressure Low
Under normal working conditions this LED is off.
This feature is disabled.
Timeout
Under normal working conditions this LED is off.
This LED will illuminate AMBER when auto-shut down has occurred.
OFF = OK
ON = Auto-shut down activated
EM Stop
If an emergency shut off button (either remote or on the panel) is pressed, the LED will
illuminate AMBER and the gas will be turned off.
The EM Stop button must be reset before restarting the system.
OFF = OK
ON = Emergency Shut-Off button activated.
Gas Detected
Under normal working conditions this LED is off.
If the external Merlin detector connected detects gas this will show RED and the gas valve will
turn off.
OFF = OK
ON = Gas detected.
CO2High
Under normal working conditions this LED is off.
If the concentration of CO2 in the air is at alarm level (relevant detector required), the LED will
show RED and the Gas valve will turn off.
OFF = OK
ON = the concentration of CO2 is at alarm level.

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 11
Servicing & General Maintenance
DO carefully remove any accumulated dust from the outer enclosure once a month.
NEVER use detergents or solvents to clean your device –this may permenantly or temporarily
damage the gas sensing elements.
NEVER spray lighter gas, paint or other aerosols near detectors or monitors.
NEVER paint devices. Paint will seal vents and may interfere with devices.
Bump Testing
What is bump testing?
‘Bump testing’ is a term used for checking a gas detector is functioning correctly by exposing it
to the target gas. A known concentration of the target gas is applied to the sensor to trigger an
alarm condition and ascertain the detector is working safely.
Why is it important?
A detector may visually appear in good order, but its sensitivity can be inhibited by external
factors. Dust, humidity, temperature fluctuations, cleaning products, contaminants or sensor
drift (ageing) can cause a decline in sensitivity and eventual failure. Regular ‘bump tests’ are
important to make sure the detector is able to detect a release of gas as early as possible.
How often?
A ‘bump test’ takes seconds and is often completed alongside a scheduled fire alarm test. We
recommend this is done at least weekly to reduce the risk of a detector not performing,
however the frequency should be determined from a risk assessment by the end user.
Please remember, ‘bump testing’ does not remove the need to have gas detectors inspected,
calibrated and serviced periodically by a trained engineer.
For more help and advice on bump testing, calibration and service –contact us.
It is recommended that any detectors connected to the system are inspected and serviced
at least annually from the date of installation for optimum performance and protection.
Avoid exposure of high concentrations of alcohol found in many products, this can damage,
deteriorate or affect gas detectors. For more information refer to your detector manual.

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 12
IMPORTANT WARNING STATEMENTS
Please take the time to thoroughly read this user’s guide which should be retained for future reference.
It is recommended that this device be commissioned upon installation.
Do not apply lighter gas or other aerosols to detectors –this will cause extreme damage to the gas sensing elements.
High concentrations of alcohol found in many products may damage, deteriorate or affect the gas sensing elements
of the detectors –Avoid exposure near your devices.
Never ignore your devices when in alarm. Actuation of your alarm indicates the presence of an error or issue that
requires immediate attention.
This device requires a continual supply of electrical power –it will not work without power.
This device should not be used to substitute proper installation, use and/or maintenance of fuel burning appliances
including appropriate ventilation and exhaust systems.
Your product should reach you in perfect condition, if you suspect it is damaged, contact your supplier.
Manufacturer’s Warranty
3 Year Manufacturer’s Warranty
Warranty coverage:
The manufacturer warrants to the original consumer purchaser, that this product will be free of defects in material and workmanship for
a period of three (3) years from date of purchase. The manufacturer’s liability hereunder is limited to replacement of the product with
repaired product at the discretion of the manufacture. This warranty is void if the product has been damaged by accident,
unreasonable use, neglect, tampering or other causes not arising from defects in material or workmanship. This warranty extends to the
original consumer purchaser of the product only.
Warranty disclaimers:
Any implied warranties arising out of this sale, including but not limited to the implied warranties of description, merchantability and
intended operational purpose, are limited in duration to the above warranty period. In no event shall the manufacturer be lia ble for loss
of use of this product or for any indirect, special, incidental or consequential damages, or costs, or expenses incurred by the consumer or
any other user of this product, whether due to a breach of contract, negligence, strict liability in tort or otherwise. The manufacturer shall
have no liability for any personal injury, property damage or any special, incidental, contingent or consequential damage of any kind
resulting from gas leakage, fire or explosion. This warranty does not affect your statutory rights.
Warranty Performance:
During the above warranty period, your product will be replaced with a comparable product if the defective product is returned together
with proof of purchase date. The replacement product will be in warranty for the remainder of the original warranty period or for six months
–whichever is the greatest.
Information on waste disposal for consumers of electrical & electronic equipment.
When this product has reached the end of its life it must be treated as Waste Electrical & Electronics Equipment (WEEE).
Any WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and
recycling of the materials used. Please contact your supplier or local authority for details of recycling schemes in your area.

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 13
Notes

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 14
Notes

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 15
Notes

Installation & Operation Manual Merlin 1000Si
1000SiIOM Rev: 06 01-20 16
Installation Details
Please pass this manual to the system owner or system user.
Date of Installation:
Installation Location:
Organisation:
Stamp/ Signature of the installer:
CONTACT US:
AGS Head Office
Tel: (727) 608-4375
Fax: (727) 538-4237
info@americangassafety.com
American Gas Safety is the owner of this document and reserves all rights of modification without prior notice.
Other manuals for Merlin 1000Si
3
Table of contents
Other AGS Controllers manuals

AGS
AGS Merlin 1000S+i Guide

AGS
AGS Merlin 1000S+ User manual

AGS
AGS Merlin 1000SW+ User manual

AGS
AGS Merlin 1000S Technical Document

AGS
AGS Merlin 1000SW+ Owner's manual

AGS
AGS Merlin GDP2 Owner's manual

AGS
AGS Merlin 500S User manual

AGS
AGS Merlin 1000Si User manual

AGS
AGS Merlin 1000S Guide

AGS
AGS Merlin 1000S User manual
Popular Controllers manuals by other brands

Hunter
Hunter X-Core XC-801i-E Owners manual and programming instructions

Exhausto
Exhausto EW 40 Installation & operating manual

BENDIX
BENDIX EC-16 ANTILOCK CONTROLLER manual

Elan
Elan RS232 installation manual

Phoenix Contact
Phoenix Contact ILC 330 Series user manual

OJ Electronics
OJ Electronics OJ-DV Series instructions