AGS DPM2 User manual

AGS DPM2 User Guide
1
Rev 04 09-20
DPM2
Dual Pressure Monitor
The DPM-2 is a dual pressure monitor which enables connection of two gas solenoid valves and two
pressure sensors to any Merlin gas proving panels.

User Guide
Please read this guide carefully and retain for future use.
The information contained within this manual should be referenced for typical installation and operation only.
For specific requirements that may deviate from the information in this guide –contact your supplier.
Information on waste disposal for consumers of electrical & electronic equipment.
When this product has reached the end of its life it must be treated as Waste Electrical & Electronics Equipment (WEEE).
Any WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and recycling of the
materials used. Please contact your supplier or local authority for details of recycling schemes in your area.
AGS DPM2 User Guide
2
Rev 04 09-20
INSTALLATION
Panel Mounting
The panel is designed for surface mounting using four screws. Removing the cover on the panel provides
access to the circuit board and mounting holes. Once the mounting and connections are finished –
secure the front panel cover with the supplied bolts and security caps.
DPM2 Wiring
A 110-120Vac supply should be connected to the terminal [MERLIN PANEL L N E] and fused at 3A.
Take care when making connections to high voltage connectors!
Any damage attempting to remove the circuit board may void any warranty!
All Class 2 wiring is to be installed within flexible tubing to maintain segregation between circuits!
Wiring of different circuits shall be separated from each other by means of routing, clamping or barrier!
AGS DPM2 User Guide
3
Rev 04 09-20
LED Status
Power
When the DPM-2 is connected to the Merlin panel and panel is connected to the mains supply, this LED
will illuminate red.
Pressure sensor 1
Under normal working conditions this LED is green.
When the panel detects a gas leak or pressure lower than 0.17psi the LED will illuminate red.
GREEN = OK
RED = gas leak or pressure below 0.17psi
Pressure sensor 2
Under normal working conditions this LED is green.
When the panel detects a gas leak or pressure lower than 0.17psi the LED will illuminate red.
GREEN = OK
RED = gas leak or pressure below 0.17psi
Specification
Product:
DPM2
Power Input Voltage
110-120Vac
Valve Output Voltage
110-120Vac
Fuse
3.15A Anti Surge 250Vac
Operating Temperature
32 –122°F 30-85%RH Non-Condensing
Wire ratings
Min. 18AWG
Pressure Sensor Operating Pressure
0-1.45psi (0-100mbar)
Important Warning Statements
Never ignore your device when in alarm.
This device should not be used to substitute proper installation, use and/or maintenance of fuel burning
appliances including appropriate ventilation and exhaust systems.
Your product should reach you in perfect condition, if you suspect it is damaged, contact your supplier.
AGS DPM2 User Guide
4
Rev 04 09-20
Manufacturer’s Warranty
Warranty Coverage: The manufacturer warrants to the original consumer purchaser, that this product will be free of defects in
material and workmanship for a period of two (3) years from date of purchase.
The manufacturer’s liability hereunder is limited to replacement of the product with repaired product at the discretion of the
manufacture. This warranty is void if the product has been damaged by accident, unreasonable use, neglect, tampering or other
causes not arising from defects in material or workmanship.
This warranty extends to the original consumer purchaser of the product only.
Disclaimers: Any implied warranties arising out of this sale, including but not limited to the implied warranties of description,
merchantability and intended operational purpose, are limited in duration to the above warranty period. In no event shall the
manufacturer be liable for loss of use of this product or for any indirect, special, incidental or consequential damages, or costs, or
expenses incurred by the consumer or any other user of this product, whether due to a breach of contract, negligence, strict liability
in tort or otherwise. The manufacturer shall have no liability for any personal injury, property damage or any special, incidental,
contingent or consequential damage of any kind resulting from gas leakage, fire or explosion. This warranty does not affect your
statutory rights.
Performance: During the above warranty period, your product will be replaced with a comparable product if the defective product
is returned together with proof of purchase date. The replacement product will be in warranty for the remainder of the original
warranty period or for six months –whichever is the greatest.
American Gas Safety LLC
Head office:
4500 140th Ave North
Suite 101
Clearwater
FL 33762
Tel: (727) 608-4375
Fax: (727) 538-4237
info@americangassafety.com
American Gas Safety LLC is the owner of this document and reserves all rights of modification without prior notice.

Other AGS Measuring Instrument manuals

AGS CO2-X Owner's manual

AGS

AGS CO2-X Owner's manual

AGS Merlin WTM Installation instructions

AGS

AGS Merlin WTM Installation instructions

AGS Merlin GDP2 Guide

AGS

AGS Merlin GDP2 Guide

AGS MERLIN CO2-TFT Instruction manual

AGS

AGS MERLIN CO2-TFT Instruction manual

AGS Mini Merlin CH4CO User manual

AGS

AGS Mini Merlin CH4CO User manual

Popular Measuring Instrument manuals by other brands

Bosch PMD 7 Original instructions

Bosch

Bosch PMD 7 Original instructions

Primes PMT 01 operating manual

Primes

Primes PMT 01 operating manual

Maxcom MXOPM26-50 Series Technical specification

Maxcom

Maxcom MXOPM26-50 Series Technical specification

Cleral KILOAD Calibration manual

Cleral

Cleral KILOAD Calibration manual

GW Instek 82PM-82120MB user manual

GW Instek

GW Instek 82PM-82120MB user manual

Freedom R8100 SERIES Operator's manual

Freedom

Freedom R8100 SERIES Operator's manual

Milwaukee MI404 user manual

Milwaukee

Milwaukee MI404 user manual

ProsKit MT-7625 user manual

ProsKit

ProsKit MT-7625 user manual

Elenco Electronics XK-700-SEMI Assembly and instruction manual

Elenco Electronics

Elenco Electronics XK-700-SEMI Assembly and instruction manual

Extech Instruments SL510 user manual

Extech Instruments

Extech Instruments SL510 user manual

ThermoFisher Scientific Orion Lab Star EC112 Operation manual

ThermoFisher Scientific

ThermoFisher Scientific Orion Lab Star EC112 Operation manual

Hanna Instruments HI 8314 instruction manual

Hanna Instruments

Hanna Instruments HI 8314 instruction manual

RS PRO RS-128M instruction manual

RS PRO

RS PRO RS-128M instruction manual

Mitutoyo ID-N manual

Mitutoyo

Mitutoyo ID-N manual

Siemens SITRANS F MAG 6000 I operating instructions

Siemens

Siemens SITRANS F MAG 6000 I operating instructions

Zeiss VISUREF 150 user manual

Zeiss

Zeiss VISUREF 150 user manual

Bushnell GOLF Phantom 2 quick start guide

Bushnell GOLF

Bushnell GOLF Phantom 2 quick start guide

Malmbergs LX1010B+ instruction manual

Malmbergs

Malmbergs LX1010B+ instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.