Aiphone LEF-3L User manual

1NAMES & FEATURES
- SUPPLEMENT TO LEF INSTRUCTIONS -
The LEF-3L is a compact, wall or desk mount master station able to selectively release a door or call up a camera.
Used with any LE- or LS-series remote station, communication can be established with each station by selecting
the channel on the master station. While the channel is selected, pressing the door release button (left of TALK
button) will release only the associated door. When used for camera call-up, a relay closure will be maintained as
long as a station is selected. The system can have up to four stations, in any combination of masters or door
stations (e.g. 2 masters and 2 doors). Master-to-master communication is also a standard feature.
(If communication between masters is not required, multiple LEF-3L's can be used to talk to 3 door stations.
LEF-3L
3-Call Master Station with Selective Control Capability (Door Release or Camera Call-up)
Used with LE-D, LE-DA, LE-DL, LS-NVP/B Door Stations
Door Release
Button
TALK Button
Station Selectors
Voice
Volume Control
Pg. 1
FEATURES:
· Selective door release control
· CCTV camera call-up capability
· Single or multiple masters can be used in a system
· Master to master communication in a multi-master system
· Single talkpath, with push-to-talk operation at master, and hands free communication
at sub station
· Large variety of sub stations available
- Surface or flush mount, with or without privacy (LE-A, LE-AN, LE-B, LE-BN)
- Weather resistant door stations (LE-D, LE-DA, LE-DL)
- Vandal proof sub stations (LE-SS, LE-SSR & LS-NVP/B)
· Subs call in with momentary tone and LED, remaining lit for approximately 20 seconds
· Selective calling to sub stations
Station Call-in LEDs
Occupied LED
Microphone
Speaker
OFF Button
1104

Individual Components for LEF-3L System:
LEF-3L 3-call master with selective door release
LE-D Surface mount door station
LE-DA Flush mount door station with stainless steel faceplate
LS-NVP/B Vandal and weather resistant sub station
SBX-NVP Surface mount box for LS-NVP/B
LE-SS Stainless Steel 2-Gang sub station
LE-SSR Stainless Steel 2-Gang sub station with red mushroom push button
SBX-2G Surface mount box for LE-SS and LE-SSR
SA-1 Surge Arrestor (1 per 2 wires being protected)
RY-PA Relay, 12V DC input, N/O dry closure output.
One required for each contact closure required
off of each channel. Can be momentary or maintained,
according to wiring.
RY-18L 12-18V DC Form C relay (N/O and N/C contacts)
PS-1225UL 12V DC, 2.5A power supply, 1 per system
LEF-3L TERMINAL DEFINITIONS:
+ Positive 12V DC
- Negative
1~3 Station number, communication to sub or other master
C "CALL", for receiving a call from another master station
E Common communication
R Occupied light control (0V DC when system is occupied)
Y All Call override control (Not used in LEF-3L system)
Color-coded Wires:
White Common Door release activation
(12V DC when door release button is pressed)
Brown Ground when station 1 is pressed
Red Ground when station 2 is pressed
Orange Ground when station 3 is pressed
WIRING & INSTALLATION:
Before Installation:
· Make sure you have the proper power supply(ies) and all necessary and compatible equipment for the system.
· Lay out your system in advance, assigning station numbers for all sub station locations.
· Surge protection for the intercom equipment is recommended. Add SA-1 surge arrestors for the power supply,
plus one per two wires connected to the master station.
Wire:
· Shielded wire is strongly recommended. Use the proper gauge for the distance being run.
· Wiring between masters must be a multi-conductor cable. If more than one cable is used to connect masters,
the "E", "C", and number terminal wires must be in the same jacketed cable. If necessary, run multiple "E"
wires, one in each cable.
Wiring Method:
· Run intercom cables at least 20" away from all AC wiring, fluorescent lights, dimmer switches, and other
electrical or electronic devices. Intercom wiring can cross AC wires at 90 degrees.
· Sub stations can be homerun to the nearest master station, or daisy-chained. If daisy-chained, include 2
common wires plus 1 individual wire per station on the run.
· In a SINGLE MASTER SYSTEM ONLY: Subs can be wired with 2 conductors homerun. Jumpers between "E"
and "-" must be attached on all subs and at the master station.
Intercom Locations:
· Do not install intercoms near dimmer or light switches, or other electrical wall devices.
· To prevent feedback, do not place sub stations back-to-back on a common wall.
Pg. 2
2COMPONENTS & WIRING
LE-D/LE-DA TERMINAL DEFINITIONS:
1 Station number
E Common communication
- Negative
LS-NVP/B TERMINAL DEFINITIONS:
Red Station number
Black Common communication
Green Negative
LE-SS/LE-SSR Color Code:
Red Station number
Black Common communication
Green Negative

LE-D/
LE-DA
3WIRING DIAGRAMS - Most Common Applications
1
E
-
2 LEF-3L, 2 Door Stations
With Master-to-Master communication shown on channel 3
With Selective Door Release
PS-1225UL
-
+
RY-PA
Dr. #2
Blk Yel
LEF-3L
1
2
3
C
E
-
+
R
Y
Wht
Brn
Red
Org
LEF-3L
1
2
C
3
E
-
+
R
Y
Wht
Brn
Red
Org
1
E
-
RY-PA
Dr. #1
Blk Yel A
AC Transformer
A
Momentary dry closure when station
is selected and "key" button is
pressed.
Connect to door strike & power.
A
1 LEF-3L, 3 Door Stations -
WIth Selective Door Release
1
E
-
LE-D/
LE-DA
LEF-3L
1
2
3
E
-
+
C
R
Y
Wht
Brn
Red
Org
LE-D/
LE-DA LE-D/
LE-DA
PS-1225UL
1
E
-
1
E
-
-
+
RY-PA
Dr. #1 RY-PA
Dr. #2 RY-PA
Dr. #3
Blk
Blk
Blk Yel
Yel
Yel
AC Transformer
NOTE:
When running 2 conductors homerun
to each sub (single master system
only), leave jumper attached between
E & - on master and door stations.
Otherwise, remove jumpers and use
separate wires for E and - terminals.
12V DC when "key" button is pressed
A
AA
AMomentary dry closure when station
is selected and "key" button is
pressed.
Connect to door strike & power.
LE-D/
LE-DA
12V DC when "key" button is pressed
LS-NVP
LE-SS
3 LEF-3L, 1 Door Station
With Master to Master Communication
Door Station wired on each station's own number terminal (different on each master)
PS-1225UL
-
+
LEF-3L #1 LEF-3L #2 LEF-3L #3
C
2
3
1
E
-
+
R
Y
Wht
Brn
Red
Org
1
C
3
2
E
-
+
R
Y
Wht
Red
Brn
Org
1
2
C
3
E
-
+
R
Y
Wht
Org
Red
Brn
Red
Blk
Grn
Blk Yel
AC Transformer
RY-PA
Dr. #3
A
AMomentary dry closure when station
is selected and "key" button is
pressed.
Connect to door strike & power.
LE-D/
LE-DA
1
E
-
Optional Remote station:
To #
To E
To -
Pg. 3

2 LEF-3L, 3 Door Stations -
No Master-to-Master Communication
Shown with door release relays
1
E
-
LE-D/
LE-DA
LEF-3L LE-D/
LE-DA LE-D/
LE-DA
PS-1225UL
1
E
-
1
E
-
-
+
RY-PA
Dr. #1 RY-PA
Dr. #2 RY-PA
Dr. #3
Blk
Blk
Blk Yel
Yel
Yel
AC Transformer
12V DC when "key" button is pressed
A
A
A
Momentary dry closure when station is
selected and "key" button is pressed.
Connect to door strike & power.
LEF-3L
1
2
3
E
-
+
C
R
Y
Wht
Brn
Red
Org
1
2
3
E
-
+
C
R
Y
Wht
Brn
Red
Org
3WIRING DIAGRAMS - Multiple Masters for Door Answering Only
A
Pg.4
RY-PA
Dr. #1
Blk Yel
12V DC when "key" button is pressed
A
RY-PA
Dr. #2
Blk Yel A
A
PS-
1225UL
-
+
LS-NVP/B
1
E
-
Red
Blk
Grn
1
2
3
C
E
-
+
R
Y
Wht
Brn
Red
Org
1
2
3
C
E
-
+
R
Y
Wht
Brn
Red
Org
1
2
3
C
E
-
+
R
Y
Wht
Brn
Red
Org
LE-D/
LE-DA
LEF-3L
LEF-3L
LEF-3L
1
2
3
C
E
-
+
R
Y
Wht
Brn
Red
Org
LEF-3L
1
2
3
C
E
-
+
R
Y
Wht
Brn
Red
Org
LEF-3L
Multiple LEF-3L's (max. 10) and 2 Door Stations
No Master-to-Master Communication
Shown with 5 masters, 2 doors. Connect up to 10 masters in parallel as shown, and up to 3 door stations.
Momentary dry closure when station is
selected and "key" button is pressed.
Connect to door strike & power.

Yellow
Yellow
Pg. 5
3WIRING DIAGRAMS (Cont.)
LE-D/
LE-DA
1
E
-
PS-1225UL
-
+
LEF-3L
1
2
C
3
E
-
+
R
Y
Wht
Brn
Red
Org
LEF-3L
1
2
3
C
E
-
+
R
Y
Wht
Brn
Red
Org
1
E
-
See other diagrams for
door release connections.
LE-D/
LE-DA
LEF-3L System with External Signaling (RY-AC)
Selective external signaling relay outputs for each door station call-in
White
Red
Black RY-AC
RY-AC
White
Red
Black
PS-1225UL
-
+
LEF-3L #1 LEF-3L #2
C
2
3
1
E
-
+
R
Y
Wht
Brn
Red
Org
Blk Yel
AC Transformer
RY-PA
Dr. #3
A
LE-D/
LE-DA
1
E
-
LEF-3L System with External Signaling (RY-AC)
One door station with the ability to activate a separate doorbell
Shown with external signaling and door release relays
White
Red
Blk RY-AC
AC Transformer
External
Sounder
To External signaling
device & power
To External signaling
device & power
Yel
1
C
3
2
E
-
+
R
Y
Wht
Brn
Red
Org

3WIRING DIAGRAMS (Cont.)
1 LEF-3L, 2 Door Stations -
Shown with both Door Release and CCTV Camera Call-up relays
1
E
-
LE-D/
LE-DA
LEF-3L
1
2
3
C
E
-
+
R
Y
Wht
Brn
Red
Org
PS-1225UL
-
+
NOTE:
This diagram shows separate E
& - wires. In single master
system only, one wire can be
used for E/- when jumper
remains attached between E & -
on master and door stations.
Yel
RY-PA
Cam. #2
Blk B
RY-PA
Dr. #1
Blk Yel A
* Diode
* Diode: 1N4001 value.
Required for door strike relay
only when 2 relays are used
on any one channel.
Yel
RY-PA
Dr. #2
Blk A
RY-PA
Cam. #1
Blk Yel B
1
E
-
LE-D/
LE-DA
* Diode
B
AMomentary dry closure when station
is selected and "key" button is
pressed.
Connect to door strike & power.
Constant closure as long as station is
selected.
Pg.6
4TROUBLESHOOTING GUIDE
ENTRY # PROBLEM POSSIBLE CAUSE SOLUTION
1Door station does not call in (no call tone
or LED light). Missing jumpers
Are there 2 or 3 conductors run to the door station? If 2 wires, jumper must remain attached between
E and - at both the door station and the master station. Replace jumper. In a multi-master system, the
E/- jumper should be removed and 3 wires should be connected.
2Door station does not call in (no call tone
or LED light) -- 3-wire connection. Missing connection of - terminal.
If communication works, check connection between - terminal of door station and master. Test call-in
at master station by touching a jumper wire between # and - terminal of master. If this rings the tone
and lights the light, the - wire from the door station is not connected properly.
3Door station does not call in (no call tone
or LED light) -- 3-wire connection. Mis-wiring of 1 and E terminals. Check that the 1 and E wire are not reversed. If they are, communication will work but call-in will not.
4 No communication to door station. Mis-wiring of E terminal.
Communication is between the 1 and E terminal of the door station to a # and E terminal of the
master station. If call-in works, check the E wire for continuity. Check the 1 and - wires at the sub to
ensure that they are not reversed.
5 No master-to-master communication. C terminals mis-wired between
masters.
Communication between masters is carried on the # wire of the calling master to the C terminal of the
receiving master. Verify that the C terminal of the master that is being called is actually wired to the #
terminal that is being selected on the calling master.
6LEF master has no communication or
tone, but LED lights work. Wrong power supply is being used. The LED lights will operate with a power source from 6VDC - 24VDC. The amplifier in the LEF unit
will only work when the system is supplied 12VDC. Proper power supply is the PS-1225UL.
7Feedback when the volume control is
turned up over halfway.
E/- jumpers attached in a multi-master
system.
Remove E/- jumpers on masters and door stations in the system, provided there are 3 wires to the
sub(s). If the sub only has 2 wires in a multi-master system, the jumper must remain in place for the
door call-in to work. In this case, the side effect is the feedback problem when the audio volume is
turned up. The only alternative is to run the proper wire to the door station(s) and remove all of the
jumpers.
8New installation has AC buzz, noise, or
hum in system.
Too close to AC and/or incorrect wire
was used.
If the units are too close to an AC source such as AC wiring or dimmer switches, move the intercom
at least one stud space away from the AC source. Other precautions include using shielded cable. If
shielded wire was used and there is still AC noise, tie all the shields together and ground to an earth
ground or negative on the power supply. If more than one jacketed cable was used between masters,
make sure the # terminals, C terminal, and the E terminals are all in the same jacketed cable. If
multiple cables were used, include an E wire in each cable that carries a station number wire in it.
9 Door release does not work. Miswire or lack of RY-PA relays.
Check the WHITE wire coming out of the PC board for voltage. When depressing the key button,
12VDC is present across WHT and negative, which activates the relay. Ensure that the black wires of
the RY-PA are connected to WHT and either the BRN, RED, or ORG wire for selective door release
(which provides selective ground when the corresponding channel is selected).
10 No call tone between masters.
No Privacy feature on LEF-3L. Features not available
The LEF-3L unit does not have the PRIVACY feature or the ability to send a call tone to another
master station (as with the standard LEF-3). This function is removed to allow the switch to be used
for door release instead of privacy.
11 Can't release the door from the 2nd
(additional masters) Wiring not connected properly. If door release works from the first master but not another(s), verify that selective door release wires
are connected between masters. (WHT, BRN, RED, ORG). RY-PA's are only required at one master.
12 External Signaling device doesn't
activate RY-AC mis-wired
Make sure that the WHITE wire of the RY-AC is connected to the # terminal that is to be activating
the relay, and that RED and BLK are connected to + and -, respectively.

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Pg. 7
LEF-3L Instr.
1104js
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
E-MAIL: [email protected]
6OPERATIONS & SPECIFICATIONS
OPERATION:
1. Pressing the call button at the door station will activate a tone, plus light the red channel LED indicator at the
master. The tone will be momentary, and the light will remain activated for approximately 20 seconds.
2. The person at the master station answers the call by pressing the selector button with the lit LED. If the LED has
already gone out, the call can still be answered by pressing the selector button.
3. Communication at the master station is "press-to-talk, release-to-listen". Communication at the door station is
hands free.
4. If the "Camera Call-up" feature is included, the associated relay will provide a maintained closure as long as the
station is selected at the master.
5. With communication established to a door station, pressing the door release button (marked with key symbol, left
of TALK button) will activate the door release mechanism at the corresponding door. The door release button will
be non-functional if a station button is not pressed.
6. When the conversation is completed, the OFF button must be pressed to disengage the call.
NOTE:
The LEF-3L does not have the "privacy feature", and also cannot send a call tone to another master or remote
station in the system.
SPECIFICATIONS:
Power Source: 12V DC at master. Use PS-1225UL.
Communication Output: 800mW @ 20 ohms (receive); 500mW @ 20 ohms (transmit)
Communication: Push-to-talk, release-to-listen at master station. Hands free at sub station.
Calling: Master to sub: By voice
Sub to master: Call tone and LED
Wiring: 2 common plus 1 individual per sub, looped; or 3 conductors homerun from each sub.
2 conductors homerun from each sub in a single-master system only.
Use Aiphone #822202 or #821802 ( 2 cond., 22 or 18AWG), or #822203 (3 cond. 22AWG)
12 conductors between master stations. Use Aiphone #822212.
Shielded cable is strongly recommended.
Wiring Distance: 650' with 22AWG; 1,600' with 18AWG.
Dimensions (HxWxD): 7-1/16" x 5-5/8" x 2-3/16"
RY-PA Contact Rating: 1A, 110V AC or 24V DC
N/O
5MODIFICATIONS
Bottom view of relay module (inside plastic case)
as it comes from the factory. (Normally Open)
CONVERTING THE RY-PA CONTACT OUTPUT TO NORMALLY CLOSED
2
1
5
3
4
To change to NORMALLY CLOSED
contact, unsolder the wire from pin 3 and
resolder onto pin 4, as shown below.
2
1
5
3
4
12V DC input Dry Cosure output
N/C
Yellow
Yellow
Black
Black
Magnetic locks require Normally Closed (N/C) contacts, keeping power applied to the magnet to
keep the door locked, and breaking power to release the door. These instructions explain how to
change the RY-PA relay output from Normally Open (N/O) to Normally Closed.
Other manuals for LEF-3L
3
Table of contents
Other Aiphone Intercom System manuals

Aiphone
Aiphone MK-1SD/B User manual

Aiphone
Aiphone GT-1M-L User manual

Aiphone
Aiphone MK-DAC User manual

Aiphone
Aiphone DA-1DS User manual

Aiphone
Aiphone AT-306 User manual

Aiphone
Aiphone YAZ-90-3 User manual

Aiphone
Aiphone LAF-10B User manual

Aiphone
Aiphone GH-1KD User manual

Aiphone
Aiphone PD-1 User manual

Aiphone
Aiphone IP-EWST Manual

Aiphone
Aiphone GM Series User manual

Aiphone
Aiphone TC-ME User manual

Aiphone
Aiphone IS SERIES Manual

Aiphone
Aiphone GT-MK User manual

Aiphone
Aiphone LA-B User manual

Aiphone
Aiphone Mk-Dh User manual

Aiphone
Aiphone MK-DS User manual

Aiphone
Aiphone IC-DC User manual

Aiphone
Aiphone MKS-2MCD User manual

Aiphone
Aiphone GM-1MD User manual