Airbi SPRING 1.1 User manual

EN
Air purifier
Airbi SPRING
Instruction manual
(version 1.1)
Please read the instruction manual carefully before using this appliance!
Page 1 of 8

EN
Important safety instructions
Please read through the operating instructions carefully before you use the appliance for the first
time and eep them safely for later reference. If necessary pass them on to the next owner.
1. The appliance is only to be used in the home for the purposes described in these instructions.
Unauthorised use and technical modifications to the appliance can lead to danger to life and
health.
2. This appliance can be used by children aged from 10 years and above and persons with
reduced physical, sensory or mental capabilities or lac of experience and nowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children without supervision.
3. After unpac ing, ma e sure that appliance wasn't damaged during transport. If you find any
damage, contact your dealer as soon as possible. We recommend you eep the pac aging for
possible future use .
4. Before first use chec that the device parameters (electric voltage, etc.) correspond to local
conditions.
5. Use appliance in an environment of 10°C to 30°C. Do not use outdoors.
6. Please put appliance more than 1 meter away from TV or radio. It is recommended to put
appliance on a flat ground in the room.
7. Do not place the appliance near a heat source. Do not subject the power cord to direct heat
(such as a heated hotplate, open flames, hot iron sole plates or heaters for example). Protect
power cords from oil.
8. Always put the appliance on a hard, flat horizontal surface. There should be a gap of at least
20 cm at both sides and bac of the product, while 30 cm from top surface.
9. Do not place anything on the appliance and do not bloc the air inlet and outlet.
10. Before using the appliance, chec if AC adapter or power cord is not damaged. Do not use it
if the cord is damaged.
11. If the power cord is damaged, it must be replaced by the manufacturer or a repair shop
authorized by the manufacturer or by similarly qualified persons in order to avoid a hazard
12. Switch off and unplug the unit before any manipulation such as cleaning of filters
maintenance.
13. Do not lift or move the appliance when it is wor ing.
14. Do not touch the power cord with wet hands, may cause electric shoc .
15. Do not insert fingers or metal objects into the air outlet gap, may cause electric shoc .
16. Do not let water, flammable detergent or other liquid get into the product, may cause electric
shoc of fire.
17. This product is not supposed to be used as daily ventilator, dust cleaner or coo er hood.
18. Do not place appliance in too humid or too hot places.
19. Do not use the appliance in aromatherapy scent insecticide environment.
20. Store the appliance in a dry place inaccessible to children (pac the appliance).
21. Manufacturer is not responsible for any damage due to improper use of appliance.
Pac ing list
•appliance
•remote control
•filters (3 pcs)
•user manual
Page 2 of 8

EN
Purifier's scheme
Control panel
Front panel
Air inlet
Front side
Top side
Control panel Handle Air inlet
Air inlet
Side view Rear view
Before first use
Ta e out filters from appliance Intall filters and front panel in this order
1. Open the front cover
1. install Antibacterial and HEPA filter – please ensure that
tab side is facing you
2. Ta e out the filters
2. install Cold catalyst and Formaldehyde removal
compound filter – please ensure that tab side is facing
you
3. Remove all pac aging
material
3. install Prefilter – please ensure that tab side is facing you
•Install bac front panel
Page 3 of 8

EN
Control overview
1
234
567
8
1. switch on/off button
2. childloc button
3. ionizer button
4. timer button
5. night mode button
6. fan speed button
7. auto mode button
8. UV lamp button
Display overview
1
23 4 5 6
78
9
1. PM2.5 - particle value
2. UV lamp icon
3. AUTO mode icon
4. NIGHT mode icon
5. ionizer icon
6. child loc icon
7. filter replacement icon
8. fan speed icon
9. air quality icon
Operation instruction
Power button
Appliance is in stadby mode after you plug in power cord to soc et. Touch the power
button. Appliance will start wor ing in AUTO mode. After you press power button once
again, appliance will switch off to standby mode.
Remar : The appliance has front panel switch and anti fall security switch. It won't turn
on when the front panel is removed or appliance falls down.
Child lock button
All button will disable when press child loc . Icon will light up and eep running. Press
this button for 3 seconds to exit this mode.
Ionizer button
Ionizer will on/off when press this button. The icon will light up and down accordingly.
Timer button
Press this button to set the wor ing time. Every time increase 30 minutes. It will recycle
after 12 hours. Display panel will show 00:30, 1:00, 1:30, 2:00....You can press 3
seconds to exit this mode. As soon as preset time expires appliance will go into standby
mode and exit timer mode.
UV button
Press this button to switch on/off UV sterilization function. Icon will light up or down at
Page 4 of 8

EN
same time.
AUTO button
Press this button to set appliance into automatic mode. Icon will light up at same time. In
this mode appliance automatically adjust fan speed level according to the degree of air
pollution. PM2.5 <60 (low speed), 60<=PM2.5<150 (medium speed), PM2.5 >=150
(high speed).
Ni ht mode button
The display panel and light will turn off when sleep mode start. Motor wor s at low
speed. Timer is available at this mode. Appliance will go into standby mode after the
time setting finish. Press any button to exit sleep mode.
Speed mode button
Press this button to control fan speed (low, medium, high) and let the appliance exit auto
mode. The motor speed won't be control by air quality sensor.
Workin time
Press child loc button for 5 seconds when in normal mode (child loc mode not active)
and you will see accumulated wor ing time of the appliance. It will disappear after 3
seconds.
Air quality icon
This icon will inform you about air quality in the room. Blue means good, orange color
means worse quality and red color indicates bad air conditions.
Product care and maintenance
Pre-filter (every 15 days)
•Please use the vacuum cleaner to clean the dust on the surface of
the screen or wash with water, dry throughly.
Cold-catalyst filter / Hi h effection formaldehyde removin filter
(every 2 months)
•Use the vacuum cleaner to clear the dust on the surface of the
screen.
•Place the filter into the ventilated place. Don't expose under the
strong sunshine.
•Do not use water to clean the filter.
Antibacterial / True HEPA filter (every 2 months)
•Use the vacuum cleaner to clear the dust on the surface of the
screen.
•Place the filter into the ventilated place. Don't expose under the
strong sunshine.
•Do not use water to clean the filter.
Page 5 of 8

EN
Ne ative ion enerator
•When you hear the appliance with a crea sound, use the brush
pen as cleaning tool, regularly clean the dust around the negative
ion.
Particle sensor (every 2 months)
•With a dry cotton swab and regular cleaning the lens to remove the moisture and smo e,
remove the outer cover of particle sensor, use the dry cotton swab to clean the lens.
•Please ensure to disconnect the power before cleaning.
•Irradiated with light when it can't see clearly.
Tips
•Ensure to disconnect the power before cleaning and maintenance.
•Please unplug power if the appliance is not in use in long time.
•According to the use of places and methods (e.g. family with many of smo ers or the place with
serious pollution), the filter life will be shortened. Please replace the filter in time.
•To clean the device, do not use any aggressive concentrated detergents.
Filtration system
1. Pre-filter: Aluminum alloy dust capturing filter at the front, with multi-layer corrugated
aluminum nets, low initial resistance, high dust capturing capacity. Is able to filter pollutants li e
large dust particles, hairs, pollen, suspended particles, etc. Is washable and reusable.
2. Cold catalyst filter: the cold catalyst will play catalyst effect in normal living environment
without any external assistance li e UV light, Sunlight, High Temperature or Pressure. It
catalyzes the formaldehyde, ammonia, benzene, TVOC, hydrogen, sulfide and other harmful
gases to wor with oxygen, and then decompose them into water and CO2
3. Hi h effection formaldehyde removin filter: This is a removal filter, designed to quic ly
adsorb and decompose formaldehyde. It is made of top-quality material for enhanced durability.
This removal filter is an ideal choice for household and office use.
4. Antibacterial filter: Antibacterial fabric resists colonization by bacteria to reduce the ris of
spreading infection and developing unpleasant odors. Long-lasting protection against unwanted
organisms.
5. True HEPA filter: Adsorbs particulate down to 0.0001mm li e pollen, drifting dust and germs
with purification efficiency of more than 99.9%. Prevention of the spread of airborne bacterial
and viral organisms.
6. UV lamp: helps clean the air. This feature is optional (it can be turned on or off).
7. Anion enerator: Double core anion generator release large amount of anions and ma e the
oxygen negatively-charged. Anions not only remove dust, ill bacteria and purify air effeciently,
they also facilitate the synthesis in human bodies and the storage of vitamins.
Page 6 of 8

EN
Replacing the filters
1. Pre-filter
2. Cold-catalyst filter / High effection formaldehyde removing filter
3. Antibacterial / True HEPA filter
The appliance has filter change reminding function. It's set at 1500 hours. Please replace Formaldehyde/
Cold catalyst filter (no. 2) and Antibacterial/HEPA filter (no. 3) when “change” icon light up. Also
please press the child loc button for 5 seconds to reset this function.
A) Press the middle of front to ma e the upper button out of its position.
B) Pull out the front panel.
C) Ta e out the filters one by one.
D) Fill in new filters one by one in a correct order.
Replacing UV lamp
UV lamp need to replace 1x during 2-3 years according its usage.
How to replace UV lamp:
•Unplug appliance from el. soc et, remove front cover and ta e out
all filters.
•Put flat-blade screwdriver under cover of UV lamp (from bottom
left side about 8 cm - 5th rib of cover) and slide it to right side
slowly until you release safety loc . After that you can pull left
side of UV lamp little bit. In this moment you can pull UV lamp
from contacts on right side (in direction to left).
•Insert UV lamp firstly to contacts on right side and then push left
side to bac of panel until you hear crac sound.
Page 7 of 8

EN
Troubleshooting
Trouble Solution
Can not turn on or button has no
response
•Chec the power cord if is plugged in.
•Chec the front plate cover if is covered.
•Chec if appliance is not in Child-loc mode.
•Chec if appliance is on the flat place.
Air is dirty, but the indicator still
show blue color.
Particle sensor is dirty, you have to clean it.
Strange sound during operation. Negative ion generator has too much dust, clean it.
Strange smell from appliance. Filters are dirty, clean or replace filters.
Purifier wor time is long, but air
quality not improved.
•Chec if you removed filter bags.
•Chec if you install filters in correct order.
Display shows F1 or F2 Please turn off the power immediately and find maintenance
department.
Technical specifiations
Rated voltage 220-240 V, 50/60 Hz
Power 80 W
Noise 28/38/55 dB (A)
Ionizer 20 million/cm3
Air performance 320 m3/h
Max. room dimension 50 m2
Dimensions 370 x 195 x 665 mm
Weight 8,5 g
Disposal of the device (environment)
The European directive 2012 / 19 / CE on Waste Electrical and Electronic Equipment (WEEE), requires that
old household electrical appliances must not be disposed in the normal unsorted municipal waste stream. Old
appliances must be collected separately in order to optimize the recovery and recycling of the materials they
contain and reduce the impact on human health and the environment. The crossed out “wheeled bin” symbol
on the product reminds you of your obligation, that when you dispose of the appliance it must be separately
collected. Consumers should contact their local authority or retailer for information concerning the correct
disposal of their old appliance.
This product is in compliance with the essential requirements and other relevant provisions of EMC directive
2014/30/EU. The device was approved for use in EU countries, therefore, bear the CE. All necessary documentation is
available at the importer address.
Changes in technical parameters, properties, printing errors in the instruction manual reserved.
Importer address:
Bibetus s.r.o.
Loosova 262/1
Brno 638 00
Czech republic
E-mail: [email protected]
Page 8 of 8
Table of contents
Other Airbi Air Cleaner manuals
Popular Air Cleaner manuals by other brands

Tanis Technologies
Tanis Technologies MODULE-AIR AF-36 Series Operating instructions & parts manual

HealthyAir
HealthyAir HA-SSC-G4 owner's manual

Dyson
Dyson Pure Cool DP04 user guide

Guardian
Guardian AC5900 user manual

GreenTec
GreenTec CAS1000 operating instructions

Amaircare
Amaircare 2500 instruction manual