Airpon AMAS-2816 User manual

AMAS-2816 Instruction of
Wireless Remote Control of Air Pump
I、The schematic diagram of Remote control:
Resume Pressure Display
Under Voltage Display
R Channel Display
Value Display
Inflation Key
Deflation Key
Head/Foot Key
Lumbar Key
Memory Key
Memory Display
RF
L Channel Display
Body State Display
Scroll Bar Display

II、Brief Introduction
AMAS-2816 Mattress Pump is applied for 2.4GHz Digital Remote Control, which can adjust hardness degree
with the double mattress of 2 chambers, so as to achieve the best sleep state. Our product uses the newest digital
wireless remote control technology, and MCU control technology, easily and conveniently to operate, beautiful
and lavish in product, it’s an ideal mattress pump.
III、Technical Parameters:
Model: AMAS-2816
Voltage: DC12V
Pressure:0-60mbar (show0-60)
Flow:20LPM
Noise: 45dB
Control Mode:Wireless remote control
Power:25W
Standby Power:2W
Weight:2.5Kg
Contour Dimension:Length270*Wide155*High90mm
IV、Operation Instruction of Wireless Remote Control:
1、Pump is connected with mattress, and connects with L and R mattress according to the pump connection
diagram.
2、Power on: Light shows red for 30s after power is on (Time for RC calibrating). Pump is in holding state and
gets ready when light turns to green. Using the RC while indicator light flickers with green, it means pump is
working.
3、Remote control lighted by pressing any key, LCD shows to work and another remote control cannot be
operated body flicker; remote control gets auto off without any operating in 15s.
4、Press Head/Foot key,the corresponding LCD will show body flickers, which can operate to Head/Foot
mattress; Press Lumbar key, the corresponding LCD will show body flickers, which can operate to Lumbar
mattress.
5、Inflation and deflation: Choose the corresponding part mattress, and press Inflation key to inflate with the part
mattress, and the digital of LCD shows increasing, meanwhile, the pressure scroll bars will roll form low to
upper, when reaches to the appropriate hardness, it will stop inflating with pressing any key; press the
Deflation key, it starts deflating for the corresponding part mattress and the digital of LCD shows decreasing,
meanwhile, the pressure scroll bar will roll from high to upper, when reaches to the appropriate hardness, it
will stop deflation when press any key; it will automatically stop when you inflate to the maximum pressure.
6、Memory value: press Memory key, LCD shows ME and memory value, the pump will automatically inflating
or deflating from Head/Foot mattress to memory value, then turn to inflate or deflate from Lumbar mattress to
memory value, then stops working or press any key to stop working.
7、Memory save: Press MEM for 3s when LCD shows or work stops to show the value state, ME flickers, it will
save the current part value of Head/Foot and Lumbar as new memory value.
8、Resume the last used pressure value: In the showing state of Head/Foot, press Head/Foot key,LCD shows
AIR,it will automatically resume the last used pressure value, in the showing state of Lumbar part, press
Lumbar key, LCD shows AIR, and automatically resume the last used pressure value.(This function is manual
resumed for the pressure drop of mattress.

V、Pay attention:
1、This RC can control 5 to 10 meters, it shows“Er”when out of the distance, please use it in its range.
2、The remote control coding: This remote control and pump are coded before leaving the factory, when it
appears “Er”in the effective distance that requires user to calibrate the code again. Method as follows:
Connect the power and during the 30s when light shows red, please press the RC lighted, then press Lumbar
key for 3S, and LCD will show SU, it means coded successfully; Another remote control coding method: wait
for the prior coded remote control auto off, cut off the pump power and restart connecting the power, the
indicator light shows 30 seconds is code window, light the remote control which needs to code, and press
Lumbar key for 3S, LCD shows SU, which indicate the coding successfully; if not succeed, please repeat the
above steps.
3、Three AAA-LR03-1.5V batteries are fitted for this RC; LCD will show the signal of its low power and please
change the batteries in time to avoid damage. Without any using in the long time please remove out the
batteries.

FCCCaution
Thisdevice complieswithpart15 oftheFCCRules. Operation issubjecttothe
followingtwoconditions:(1)Thisdevice maynotcauseharmfulinterference,and (2)
thisdevice mustacceptanyinterferencereceived, including interferencethatmay
causeundesired operation.
AnyChangesormodifications notexpresslyapprovedbythepartyresponsiblefor
compliance could void theuser's authorityto operatetheequipment.
Note: Thisequipmenthasbeentestedand foundtocomplywiththelimitsforaClass
Bdigitaldevice,pursuanttopart15 oftheFCCRules. Theselimitsare designedto
providereasonableprotection againstharmfulinterferenceinaresidentialinstallation.
Thisequipmentgeneratesusesand canradiateradiofrequencyenergyand, ifnot
installedand usedinaccordancewiththeinstructions, maycauseharmfulinterference
toradiocommunications. However,there isno guaranteethatinterference will not
occurinaparticular installation. Ifthisequipmentdoescauseharmfulinterferenceto
radioortelevision reception, whichcanbedeterminedbyturning theequipmentoff
and on, theuser isencouragedtotrytocorrecttheinterferencebyoneormore ofthe
followingmeasures:
-Reorientorrelocatethereceivingantenna.
-Increasetheseparation between theequipmentand receiver.
-Connecttheequipmentintoanoutleton acircuit differentfromthattowhichthe
receiver is connected.
-Consult thedealer oranexperienced radio/TVtechnician forhelp.
Table of contents