Airtronic LT-700 User manual

LT-700
Stationary Terminal
Operating Manual

LT-700
Stationary Terminal
Operating Manual

We don’t deliver just our mobile Data Capturing Devices
with Standard Software...
but also develop to customers specific
•Applications for this Devices
•PC Applications
•Hardware
and advise you on
•Creating concepts for mobile and stationary data collection
•Queries surrounding Bar Code and RFID
•Hardware problems
Please consult us with your queries or problems at:
aitronic GmbH
Balhorner Feld 10
D-33106 Paderborn
Germany
Phone: +49 (0) 5251 29816-0
Fax: +49 (0) 5251 29816-40
Internet: http://www.aitronic.de
___________________________________________________________
Copyright aitronic GmbH, 2015
All Rights reserved, in particular all extracts which correspond to the
translation, the reprint and reproduction by copying or similar methods.
Delivery and technical changes are subject to change.

Content___________________________________________________________________ 1
____________________________________________________________________ aitronic
Connectors ............................................................................ 3
Designations.......................................................................... 4
Start Page............................................................................... 5
CONFIGURATIONS MANAGER............................................. 6
SERVER MENU....................................................................................................7
WEB-APPLICATION-SERVER.........................................................................8
MDE-SERVER...................................................................................................9
DNC-SERVER.................................................................................................10
NETWORK MENU..............................................................................................11
LT-700 Terminal LAN Settings .....................................................................11
LT-700 Router Administration......................................................................12
Login ...........................................................................................................13
Status..........................................................................................................14
System ........................................................................................................15
Network.......................................................................................................16
Logout.........................................................................................................16
Factory Default..................................................................................................17
Factory Default Settings ...............................................................................17
Resetting to Factory Default State...............................................................18
Deviating from the default Settings ................................................................18
WAN Interface with static IP Address..........................................................18
Setting up Wi-Fi Wireless (WWAN)..............................................................19
Main Operating Modes........................................................ 20
LAN-Mode..........................................................................................................20
WLAN Mode.......................................................................................................21

Content___________________________________________________________________ 2
____________________________________________________________________ aitronic
Services and Programs....................................................... 22
MDE (ai-mde).....................................................................................................22
Program Start.................................................................................................22
Output Format................................................................................................22
JSON ...........................................................................................................22
CSV..............................................................................................................23
NONE...........................................................................................................23
Offline Data Storage......................................................................................23
DNC (ai-dnc)......................................................................................................23
Program Start.................................................................................................23
Configuration.................................................................................................24
Open Data Port ..............................................................................................24
Close Data Port..............................................................................................24
Debug Control................................................................................................25
Heartbeat Control..........................................................................................25
Clear Data Port Buffer...................................................................................25
Status Query..................................................................................................26
Return Error/Message...................................................................................26
Return Status.................................................................................................27
Firmware Update of the LT-700.......................................... 28
By means of Firmware Image from SD Card..................................................28
Default Port Configuration.................................................. 29
Eliminating Errors ............................................................... 30
Technical Data..................................................................... 31

Connectors______________________________________________________________
____________________________________________________________________ aitronic
3
Connectors
ETHERNET LAN0(WAN) LAN/WAN
ETHERNET LAN1 LAN
USB A1/A2 Connector for external devices with USB Interface (e.g.
barcode scanner)
USB B USB Host Interface
MDE INPUT/OUTPUT RS-232 for connection of a MDE device
DNC RS-232 for connection of a DNC Machine
DC_IN 12V-24 V Power Supply
ETHERNET USB USB USB MDE DNC DC_IN
LAN0(WAN) LAN1 A1 A2 B INPUT/OUTPUT 12V-24V

Designations_____________________________________________________________
____________________________________________________________________ aitronic
4
Designations
LT-700 is the name for the entire device, containing the LT-700
Terminal and the LT-700 Router.
LT-700 Router consists essentially of the WIZnet module and is part of
the LT-700.
LT-700 Terminal essentially consists of the Linux computer and is part of
the LT-700.

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
5
Start Page
After a cold start of the LT-700, the web page, which is specified in the WEB
APPLICATION SERVER under URL, is displayed. By default, this is the page
https://www.aitronic.de/de/impressum:
Startseite
By holding down the key and pressing key F1 the CONFIGURTAIONS
MANAGERs login screen is called.

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
6
CONFIGURATIONS MANAGER
The buttons at the bottom of the CONFIGURATION MANAGER are assigned by
their respective position to the function keys F1 ... F5 which are located below the
display. On the following login page, for example, the following function keys can
be used as an alternative to the buttons:
START F1
LOGIN F5
Login-Seite
START Return to the Start Page
Password 1478963
LOGIN Calling the Menu Main Page
Menu Main Page
START Return to the Start Page
NETWORK Calling page NETWORK MENU
SERVER Calling page SERVER MENU
Software Version

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
7
SERVER MENU
SERVER MENU
<back Return to the Menu Main Page
WEB Calling page WEB-APPLICATION-SERVER
DNC Calling page DNC-SERVER
MDE Calling page MDE-SERVER
Connections to a web server, which determines the user interface of the device, to
a DNC server serving the communication of a serial interface and to an MDE
server, which is responsible for the storage and analysis of MDA data, can be
established.

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
8
WEB-APPLICATION-SERVER
WEB-APPLICATION-SERVER
Active ai-browser will be started when booting the system
Protocol Connection Protocol
URL Host IP
Port Host Port
Path Path and start of web page
User User
Passw Password
Debug Log information:
stdout Output on the standard console
file Output to file /var/log/aiBrowser.log
none no debug output
<back Return to page SERVER MENU
<save> Save settings

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
9
MDE-SERVER
MDE-SERVER
Active ai-mde will be started when booting the system
Format Output format
URL Host IP
Port Host Port
Spool-Dir Path and name of spool file
Debug Log information:
stdout Output on the standard console
file Output to file /var/log/aiMDE.log
none no debug output
<back Return to page SERVER MENU
<save> Save settings

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
10
DNC-SERVER
DNC-SERVER
Active ai- dnc will be started when booting the system.
URL Host IP
Port Host Port
Debug Log information:
stdout Output on the standard console
file Output to file /var/log/aiDNC.log
none no debug output
<back Return to page SERVER MENU
<save> Save settings

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
11
NETWORK MENU
NETWORK MENU
<back Return to page SERVER MENU
TERMINAL LT-700 Terminal LAN Settings
ROUTER LT-700 Router Administration
LT-700 Terminal LAN Settings
<back Return to page NETWORK MENU
<save> Save settings
DHCP Enabling DHCP, the DHCP server of the LT-700 router provides the
necessary settings
IP IP Address of LT-700 Terminal
Netmask Netmask of LT-700 Terminal
Gateway Gateway of LT-700 Terminal
DNS Domain Name Server of LT-700 Terminal

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
12
LT-700 Router Administration
There are several ways for the administration of the LT-700 Router (the specified IP
addresses are valid only if the appropriate settings have not been changed):
LT-700 The LT-700 Router administration can be done directly via the user
interface of the LT-700. Please note the following:
For operation only the corresponding buttons are available. An
operation via function keys (such as under the SERVER MENU) is
not possible here.
For the achievement of any existing buttons it may be necessary
to scroll down.
Far more comfortable but is a PC/Laptop with Internet browser via
the following physical connections.
WAN The IP address of the LT-700 Router (default assignment with
DHCP) can be checked on the LT-700 after calling the
CONFIGURTAIONS MANAGER on the page
NETWORK→Login→Status→Overview under section "Network".
WLAN A connection to the wireless access point of the LT-700 has to be
established. All LT-700 Wireless Access Points have the SSID
multirans-i-nnnnnn in which nnnnnn are the last digits of the
MAC address. The configuration via the web interface of the LT-700
Router is made via http://192.168.210.1.
LAN Ein an das LAN-Interface angeschlossener PC/Laptop bekommt per
DHCP eine IP-Adresse innerhalb des 210-Netzes zugewiesen.
A PC/Laptop connected to the LAN interface gets assigned an IP
address via DHCP within the 210 network. The configuration via the
web interface of the LT-700 Router is made via
http://192.168.210.1.
NOTE: When using a browser the functions "store access data" and
"AutoFill" should be disabled.

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
13
Login
The authorization is made with the password "1478963".
On the following pages is a rough outline of where to find what settings.

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
14
Status
Overview About respectively status of system, memory, network, DHCP
/ DHCPv6 leases, wireless and associated stations
Firewall IPv4 and IPv6 Firewall Status
Routes ARP Table and active IPv4 and IPv6 routes
System Log System Log
Kernel Log Kernel Log
Processes Overview of the active system processes and their states
Realtime Graphs Graphical representations of load, traffic, wireless and
Connections

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
15
System
System Settings of hostname, time zone, time synchronization, and
logging
Administration Router Password and SSH Access
Software Configuration, installed and available packages, download
and installation of packages
Startup Enable/disable of installed init scripts
Scheduled Tasks Definition of scheduled tasks
LED Configuration Customizing the behavior of the device LED’s
Backup / Flash Backup / Restore configuration files, reset to default, flashing
Firmware a new firmware image
Reboot System Reboot.

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
16
Network
Interfaces Overview of the interfaces LAN, WAN, WLAN, global network
options
Wifi Wireless overview, associated stations.
Switch Virtual Local Area Network Settings (VLAN).
DHCP and DNS DHCP and DNS settings
Hostnames Definition of host names and IP addresses
Static Routes Routes specify via which interface and gateway a certain host
or network can be reached
Firewall Firewall Settings
Diagnostics Network Utilities
Logout
After the logout the Login Page is displayed again.

CONFIGURATIONS MANAGER _____________________________________________
____________________________________________________________________ aitronic
17
Factory Default
Factory Default Settings
Fixed IP Addresses The following IP addresses are fix and are not allowed to be
changed:
LT-700 Router: 192.168.210.1
(LT-700 Router Administration
Network→Interfaces→LAN)
LT-700 Terminal: 192.168.210.210
(LT-700 Terminal LAN Settings)
DHCP Server The IP address range within which the DHCP server assigns
the IP’s for the LAN interface, is 100 ... 149 and can be set in
the LT-700 Router Administration under System→Interface.
The LAN interface has not to be connected to the
corporate LAN, because IP conflicts may arise due to
over-reach DHCP server.
WLAN In the LT-700 Router Administration under Network→Wifi Wifi
is enabled and the master mode set (WLAN Access Point). A
wireless client can connect to it with the following credentials:
SSID: „hostname-xxxxxx“
(hostname is „lt-700“, xxxxxx are the last 6 digits
of the MAC address of the WAN interfaces and
are only added automatically when the host name
is „lt-700“)
Password: „aitronic“
If Wifi is disabled, no LT-700 Router Administration is
possible via WLAN!
WAN is set in the LT-700 Router Administration under
Network→Interfaces→WAN as DHCP Client with hostname
"hostname-xxxxxx" (hostname "lt-700" xxxxxx are the last 6
digits of the MAC address of the WAN interfaces and only
automatically added thereto, if the host name "lt 700").
SSH Access is enabled in the LT-700 Router Administration under
System→Administration for all interfaces.
Table of contents
Popular Touch Terminal manuals by other brands

Universal Ubiquitous
Universal Ubiquitous OS-M340Q1-0G0G-R02WFC Product Booklet

Olimpia splendid
Olimpia splendid Bi2 B0772 Instructions for mounting and use

PIONEERPOS
PIONEERPOS Magnus XV-2 Specifications

Beckhoff
Beckhoff ELX3252 operating manual

eCOMM
eCOMM S800 user guide

OJ Electronics