manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Airwell
  6. •
  7. Controllers
  8. •
  9. Airwell RWV01 User manual

Airwell RWV01 User manual

Other Airwell Controllers manuals

Airwell RWV03 User manual

Airwell

Airwell RWV03 User manual

Airwell RWV04 User manual

Airwell

Airwell RWV04 User manual

Airwell RCW30 User manual

Airwell

Airwell RCW30 User manual

Airwell CCM30/BKE-A Operating instructions

Airwell

Airwell CCM30/BKE-A Operating instructions

Airwell WELLEA MONO SPLIT A R32 User manual

Airwell

Airwell WELLEA MONO SPLIT A R32 User manual

Airwell AHU V2-7ACELH040 User manual

Airwell

Airwell AHU V2-7ACELH040 User manual

Airwell RCW30 User manual

Airwell

Airwell RCW30 User manual

Airwell RCW22 Installation instructions

Airwell

Airwell RCW22 Installation instructions

Airwell RCW21 User manual

Airwell

Airwell RCW21 User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Wired Controller
Operation & Installation Manual
•Please read this operation manual before using the air conditioner.
•Please keep this manual carefully and safely.
CONTENT
Parts and Functions............................................................ 1
Operation............................................................................ 9
Wired Controller Wiring Instruction................................... 46
New RWV01
1
Interface Display
Parts and Functions
2
ON/OFF
Adjusting key for temperature, clock, timer, sleeping
adjustment, temp. compensation and energy saving;
Inquiring key for detail parameter and malfunction inquiry;
Switching key for function switch.
The adjusting accuracy of temperature is 0.5°C (1°F). If energy
saving mode is not set, the adjusting range is from 16°C
(60°F) to 30°C (86°F). If energy saving mode is set, the lowest
temperature limit of cooling/dry and the highest temperature
limit of heating are decided by the setting of the chip, the
default cooling/dry temperature is 23°C (74°F), and the default
heating temperature is 26°C (78°F).
Note:
•If the dip switch Sw2 is “on”, it displays the ambient temp., as
well as when powered off. From power off to power on, mode
switching and set temp. adjustment, it ashes to display SET
icon and statically displays the set temp.. And then statically
displays the ambient temp. and ROOM icon after 3 seconds.
In energy saving mode and temp. compensation mode, the
adjusting step is 1°C (1°F) a time.
Key
Parts and Functions
3
•  If using Fresh Air unit, set temp. cannot be adjusted. If there
is no Central/Lock set, the temp. will be xed at 18°C (64°F) 
in cooling and 22°C (72°F) in heating. The Up/Down key will
not display in normal state, but will display and valid in timer
setting, function selection, unit shift in malfunction inquiry,
parameter shift in parameter check, unit No. setting, sleeping
time adjustment, etc.
24-hour, press once to minus one minute. Keep pressing,
minus 2 minutes in 1 second’s pressing, then 10 minutes
in 5 seconds. The time will keep decreasing at the pace of
10 minutes a time in 10 seconds. Vice-versa. Press to
conrm or it will turn back to the previous state automatically in 
10s.
Parts and Functions
Press this key to execute mode switch. For detailed 
information, please refer to mode setting.
Note: If using Fresh Air unit, default 3 modes will circulate from
cooling→heating→fan→cooling.
4
Pressing this key, fan speed will be changed in sequence as
follows:  (Low) →  (Medium)
→   (High)→ 
(Auto) →  (Low)
Note: Auto fan will be changed in sequence as follows:
 →   → 
 → 
Pressing this key, fan speed will be changed in sequence as
follows (Only valid for parts of models):
 (Breeze) →   (Low)  → 
 (Medium) → 
(High) →   (Super) → 
 (Auto) →  (Breeze)
Auto fan circulation:
 (Breeze) →   (Low)  → 
 (Medium) → 
(High) →  (Super)
There is no auto fan in fan mode; The fan icon will ash when 
adjusting the fan speed. It will statically display after the
adjustment.
Parts and Functions
5
Timer ON, Timer OFF, Timer ON/OFF.
Press this key to enter function circulation. If it is the four-
way cassette model, press Set key for 5s to enter function
circulation.
1.Press to select the functions in sequence as follows:
 (Only when Left/Right swing is valid) →  (Only when Up/
Down swing is valid) →   →   (ventilation function) → 
(reserved function) →   (When it’s time for lter cleaning, 
this icon will involve in circulation) →  (the second 8 of
88.8 in the temp. display area displaying A,only valid for part
of models)→  (the second 8 of 88.8 in the temp. display
area displaying B,only valid for part of models)→  (motion
sensing,only valid for part of models) →10°C heating function 
(this function only works in the heating mode, only valid for
part of models) → health airow up (Only valid for part of 
models) → health airow down (Only valid for part of models)
Parts and Functions
Note: If using Fresh Air unit, fan will be in auto fan and cannot
be adjusted. If press FAN key, fan icon and FFFF on the
top-right corner will ash, prompting fan speed cannot be 
adjusted, and will statically display after 3s. Fresh Air unit fan
speed will be controlled automatically by indoor unit and wired
controller will always display auto fan.
6
2.Press to select the functions in sequence as follows:
health airow down (Only valid for part of models) → health 
airow up (Only valid for part of models) →10°C heating 
function (this function only works in the heating mode, only
valid for part of models) →  (motion sensing,only valid
for part of models) →  (the second 8 of 88.8 in the temp.
display area displaying B,only valid for part of models) → 
(the second 8 of 88.8 in the temp. display area displaying
A,only valid for part of models) →   (When it’s time for lter 
cleaning, this icon will involve in circulation) →  (reserved
function) →   (ventilation function) →   →  (Only when
Up/Down swing is valid) →  (Only when Left/Right swing is
valid)
3. Press  to conrm function selected. If there is function 
selected, press can cancel this function.
Note: The Left/Right swing is valid only after the dip switch
is set, the lter icon   is shown only after the lter requires 
cleaning.
Parts and Functions
7
Parts and Functions
Icon
Clock; Parameter setting/inquiry; Malfunction
display; Mode setting.
Timer ON/OFF: Sleeping; Parameter setting/
inquiry; Malfunction display.
ROOM/SET temp. and humidity display, each
step is 0.5°C (1°F) . For example, if the temp. 
is 25°C (77°F), it will display 25.0°C (77°F).
Humidity display function is reserved.
Energy Saving, This icon will be displayed
only when energy saving function is set.
Filter Cleaning.
Child Lock. This icon will be displayed only
when child lock function is set.
/ Lock/ Central
Motion Sensing (Only valid for part of
models).
Left/Right Swing. This icon is displayed in
swing mode; no display without swing mode.
Up/Down Swing. This icon is displayed in
swing mode; no display without swing mode.
8
Parts and Functions
Sleeping. This icon is displayed when setting the
sleeping, and left time of sleeping is displayed by
Heat Reclaim Ventilation, This icon is displayed when
setting the heat reclaim ventilation.
Electrical Heating. This icon will display when electrical
heating is set on DC wired controller.
Intelligent Mode.
Cooling Mode. Heating Mode.
Fan Mode. Dry Mode.
Breeze Fan Speed (Only
valid for part of models)
Low Fan Speed.
Medium Fan Speed.
High Fan Speed.
Super Fan Speed (Only
valid for part of models)
If the fan speed is set in auto fan, it will change in the
following sequence: Breeze(Only valid for part of models)
→Low→Medium→High→Super (Only valid for part of 
models), AUTO icon will display simultaneously.
9
Dip Switch Interpretation (for AC)
Operation
DIP
switch
On/Off
station Function Default
setting
Sw1 On Slave wired controller Off
Off Master wired controller
Sw2 On Ambient temp. display on Off
Off Ambient temp. display off
Sw3
On Collect ambient temp. from PCB of
indoor Off
Off Collect ambient Temp. from wired
controller
Sw4 On Non-volatile memory invalid Off
Off Non-volatile memory valid
Sw5 On Old protocol Off
Off Selfadaption
Sw6 On reserved Off
Off reserved
Sw7 On Model with Up/Down and Left/Right
swing Off
Off Model with Up/Down swing
Sw8 On Fresh Air unit Off
Off General unit