QUICK GUIDE
Motorstyring / Motor Controller
Type TR-EM-239
Forhandler / Distributor:
LINAK Danmark A/S
Mønstedsvej 9
DK-8600 Silkeborg
Tlf. +45 86803611 - www.linak.dk
Specifikationerne kan ændre sig uden forudgående varsel. Det er brugerens ansvar at fastslå
LINAK produktets egnethed til en specifik applikation. LINAK vil ved levering ombytte/reparere
defekte produkter, som er dækket af garanti, hvis de straks returneres til LINAK Danmark A/S.
Der påtages intet ansvar udover denne ombytning/reparation.
Produceret af / Produced by Electromen OY
Parameterindstillinger / Parameter settings
Specifications subject to change without prior notice. It is the responsibility of the product user to
determine the suitability of the products for a specific application. LINAK Danmark will at point of
delivery replace/repair defective products covered by the warranty if promptly returned
to LINAK Danmark. No liability is assumed beyond such replacement/repair.
Opstart (initialisering)
1. Start initialisering ved at trykke på PIL-OP og PIL-NED
på samme tid i >3 sekunder.
2. Initialiseringen kan afbrydes ved at foretage en ny proce-
dure som beskrevet under punkt 1.
3. Begge aktuatorerne starter med at køre indad indtil strøm-
grænsen er nået eller pulstab stopper motorerne
når det mekaniske endestop er nået.
4. Under hele initialiseringspprocessen, blinker fejl LED’en
og stopper når begge motorer er stoppet. Enheden er nu
nulstillet og pulstællerne er sat til nul.
5. Systemet er klar til brug.
Starting up (initialization)
1. To initiate the system, push ARROW UP and ARROW DOWN
simultaneously for >3 seconds.
2. The routine can be interrupted with a new activation on the
buttons discribed under point 1.
3. Both actuators starts running inwards until current limit stops
the motors or pulses stops coming .
4. During the drive routine the fault LED will blink slowly. When
blinking stops and both motors have stopped, the device has
reset the pulse counters.
5. The system is now ready for use.
Tilslut programmeringsenheden TR-EM-236 og indlæs
nedenstående værdierne for det pågældende aktuatorsæt
Connect the programming unit TR-EM-236 to the PCB and
enter the values from the list below for the resp. Actuators
* Værdi gældende for 24V -motor. For 12V -motor -se datablad. * Value is valid for use with 24V -motor. Please refer to Data sheets
ror use with 12V -motor.
For yderligere vejledning, henvises til brugsanvisningen
på www.linakthirdparty.com
For detailed instructions please refer to the Instruction
manual at www.linakthirdparty.com
Pa ra me ter Reed
LA12
Single-Hall
LA14/LA25
DualHall
LA23
Reed
LA28 Reed
LP2 Reed
LA30 Reed
LA31 Reed
LA32
Hall
LA35
Hall/Dual
LA36
1
100 100 100 100 100 100 100 100 100 100
2
60 60 60 60 60 60 60 60 60 60
3
5 5 5 5 5 5 5 5 0 5
4
0 0 0 0 0 0 0 0 0 0
5
20* 20* 20* 50* 50* 50* 50* 50* 50* 100*
6
10 10 10 10 10 10 10 10 10 10
7
5 5 5 5 5 5 5 5 5 5
8
0 0 0 0 0 0 0 0 0 0
9
1 1 1 1 1 1 1 1 1 1
10
1 1 1 1 1 1 1 1 1 1
11
0 0 0 0 0 0 0 0 0 0
12
0 0 0 0 0 0 0 0 0 0
13
0 0 1 0 0 0 0 0 0 1
14
0 0 0 0 0 0 0 0 0 0 0
DIP
Neg. Neg.
Pos. Pos. Pos. Pos. Pos. Pos. Pos. Pos. Pos.
Hall/Dual
LA40 Single-hall
BL1
100 100
60 60
3 5
0 0
40* 50*
10 10
5 5
0 0
1 1
1 1
0 0
0 0
1 0
0
Pos.