AIYI Technologies AGH6200 User manual

1
AIYI Technologies
Operator’s Manual
AGH6200/AGH6200F
Version:3.3.1901

1
AIYI Technologies
Dear customer:
Glad to have your trust and support on AIYI Technologies, we will
provide you best product and service in return.
As an ISO cered manufacturer. AIYI Technologies has been focus on
safety and environment many years, we provide you gas & dust detec-
tor and systems. The design and manufacture of product is strictly
follow the internaonal standard and company regulaons, and each
product get a normave QC control to ensure the best quality for you.
Please read and understand this operator’s manual before operang
instrument. Improper use of the gas monitor could result in bodily
harm or death. Please don't hesitate to contact us if you have any
quesons or suggesons. Thanks!
We are honored to have the opportunity to serve you.
Yours sincerely.

2
AIYI Technologies
Copyright Statement
Copyright© 2017 AIYI Technologies .All Rights Reserved.
This document is the property of AIYI Technologies. And can be nei-
ther reproduced nor disclosed to a third party without a wrien authorizaon.
is the registered trademark of AIYI Technologies. The others inside of the
document belongs to other companies.
Disclaimer
This manual, as well as the soware described in it, is furnished under license and may be used or
copied only in accordance with the terms of such license. The content of this manual is furnished
for informaonal use only, is subject to change without noce, and should not be construed as a
commitment by AIYI Technologies. (AIYI Technologies ) AIYI Technologies assumes no responsibility
or liability for any errors or inaccuracies that may appear in the manual.
Except as permied by such license, no part of this publicaon may be reproduced, stored in a
retrieval system, or transmied, in any form or by any means, electronic, mechanical, recording, or
otherwise, without the prior wrien permission of AIYI Technologies.
AIYI TECHNOLOGIES MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITA-
TION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
REGARDING THE AIYI TECHNOLOGIES INSTRUMENT. AIYI TECHNOLOGIES DOES NOT WARRANT,
GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OR THE RESULTS OF THE USE
OF THE INSTRUMENT IN TERMS OF ITS CORRECTNESS, ACCURACY, RELIABILITY, CURRENTNESS, OR
OTHERWISE. THE ENTIRE RISK AS TO THE RESULTS AND PERFORMANCE OF THE INSRTUMENT IS
ASSUMED BY YOU. THE EXCLUSION OF IMPLIED WARRANTIES IS NOT PERMITTED BY SOME STATES.
THE ABOVE EXCLUSION MAY NOT APPLY TO YOU.
IN NO EVENT WILL AIYI TECHNOLOGIES, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE
LIABLE TO YOU FOR ANY CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES (INCLUDING
DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFOR-
MATION, AND THE LIKE) ARISING OUT OF THE USE OR INABILITY TO USE THE AIYI TECHNOLOGIES
INSTRUMENT EVEN IF AIYI TECHNOLOGIES HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAM-
AGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.

3
AIYI Technologies
Statement
The manual is applicable to the use and maintenance of AGH6200 & AGH6200F
series gas detector.
This manual is suitable for the following personnel: instrument maintenance
engineers, eld users.
Aenon: Before connecng and operang your device,
please be advised of the manual.

4
AIYI Technologies
CONTENT
Chapter 1: Product Introducon
1.1 Brief introducon …………………………………………………………05
1.2 Instrument descripon……………………………………………………07
1.3 Interface descripon………………………………………………………08
1.4 Specicaons………………………………………………………………09
Chapter 2: Operaon
2.1 Packing list ………………………………………………………………10
2.2 Power on/o………………………………………………………………10
2.3 Daily use …………………………………………………………………11
2.4 Operaon …………………………………………………………………12
2.5 Charging …………………………………………………………………17
2.6 Data upload ………………………………………………………………17
Chapter 3: Maintenance
3.1 Cauons …………………………………………………………………17
3.2 Warranty …………………………………………………………………18

5
AIYI Technologies
Chapter 1 Product Introducon
1.1 Brief introducon
The AGH6200 and AGH6200F portable gas detector are independently developed and
produced by AIYI Technologies, which can be used in industrial sites to detect the risks
of combusble gases, carbon monoxide, hydrogen sulde and oxygen deciency. The
overall design of the product is compact, which greatly improves the comfort of the
customer. The high-precision sensor is used for accurate detecon and easy mainte-
nance. The IP66 protecon grade can be applied to all kinds of bad occasions.
Note: The AGH6200F is a portable combusble gas detector with a measuring range
of 0 to 100% LEL. The AGH6200 is a portable 4 gas detector, the following are referred
to as detectors.
The main funcons and features of the product:
▎Detect combusble gas, oxygen, carbon monoxide and hydrogen sulde.
▎Imported sensors with high sensivity.
▎Various alarm modes of sound and light and vibraon, eecvely alert.
▎Double case design, IP66 protecon, dust and water proof .
▎Intrinsically safe design for use in hazardous locaons.
▎Standard Micro USB interface for easy charging and data export.
▎Compact and lightweight, easy to carry.
The product design, manufacture, tesng follow the below standards:
The AGH6200F is only equipped with a combusble gas sensor; the AGH6200 is
equipped with four gas sensors: combusble gas, oxygen, carbon monoxide and
hydrogen sulde. Except for dierent gases detected, the two operaons are
exactly the same. The following is an example of AGH6200. Unless otherwise
specied, AGH6200F is not separately described.

6
AIYI Technologies
▎GB 15322.1-2003 Combusble gas detectors--Part 3:Portable type detectors
for 0-100% LEL combusble gas
▎GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General require-
ments
▎GB 3836.2-2010 Explosive atmospheres—Part 2:Equipment protecon by
ameproof enclosures“d”
▎GB 3836.4-2010 Explosive atmospheres—Part 4:Equipment protecon by
intrinsic safety i
▎GB 50493-2009 Specicaon for design of combusble gas and toxic gas de-
tecon and alarm for petrochemical industry
▎GB 12358-2006 Gas monitors and alarms for workplace General technical
requirements
▎GB 16838-2005 Envionmental test methods and severies for re electronic
products
▎GB/T 4208-2017 Degrees of protecon provided by enclosure(IP code)
▎GB/T 18664-2002 Selecon, use and maintenance of respiratory protecve
equipment
▎GBZ 2.1-2007 Occupaonal exposure limits for hazardous agents in the work-
place Part1:Chemical hazardous agents
▎Q/3201 AECN 009-2018 AGH6200 portable gas detector
▎Q/3201 AECN 010-2018 AGH6200F portable gas detector
1.2 Instrument descripon

7
AIYI Technologies
1.3 Interface de-
scripon
1Indicator light 2LCD screen 3Buon
4Calibraon kit adapter 5Sensors 6Buzzer
7Alarm LED light 8Alligator clip 9Nameplate
Funcon Choose, Exit
Power ON/OFF, Menu, Conrm
Fault Yellow light keeps on
Alarm Red light ashes
Power Green light ashes
Funcon Power

8
AIYI Technologies
1 Task bar
Zero calibraon
Span calibraon
Self-test
USB connecon
Power
2Status bar
Gas detected, eg: Ex O2 CO H2S
STEL Short term exposure limit
TWA Time weighted average
Low alarm
High alarm
3Readings bar
Display the current gas concentraon
5Time bar
Display current me
4Unit bar
%LEL lower explosive limit
ppm Parts per million
%Percentage
μmol/mol One millionth mol gas per
mol air
note:1ppm = 1μmol/mol

9
AIYI Technologies
1.4 Specicaons
Model AGH6200F AGH6200
Gas detected Ex Ex O2 CO H2S
Measure range Ex: catalyc combuson CO: electrochemical
O2: electrochemical H2S: electrochemical
Detecon principle Ex: 0~100%LEL CO: 0~1000µmol/mol
O2: 0~30%VOL H2S: 0~100µmol/mol
Dri
Ex: ±5%F.S CO: Absolute error ±5%µmol/mol
or relave error ±10%
O2: ±3%F.S H2S: ±5µmol/mol
Response me ≤30s (T90)
Sampling method Diusion sampling standard
Alarm method Sound, light (3 LEDs), vibraon
Operang temperature -40~70℃-10~55℃
Operang humidity ≤95%RH
Explosion-proof grade ExdibIICT4 Gb ExdibIICT4 Gb
Ingress protecon IP66
Baery Rechargeable 3.7v lithium baery in 2200mAh
Charge Voltage DC5V
Connuous operaon ≥18h
Case material Anstac TPU + Anstac PC
Dimension 132mm*63mm*48mm(including alligator clip)
Weight About 270g About 285g

10
AIYI Technologies
Chapter 2 Operaon
2.1 Packing list
Please conrm if the package is complete before use. If there is any loss, please con-
tact us as soon as possible. Normally, the gas detector contains the following products
and accessories:
▎Power on: press and hold the power buon, the detector enters the boot pro-
cess, and the full screen ashes 3 mes during the boot process, and then displays
the STEL alarm value, TWA alarm value, alarm-1 value, alarm-2 value and calibraon
value of each channel in turn.
Item name Quan
ty Item name Quan
ty Item name Quan
ty
Detector 1Calibraon cercate &
QC cercate 1Calibraon adapter 1
Manual 1Charger(including USB
Cable) 1
Full screen interface STEL alarm value TWA alarm value
Alarm-1 value Alarm-2 value Calibraon value
2.2 Power on/o

11
AIYI Technologies
▎Power o: Press and hold the power buon to enter the shutdown interface.
All the indicator lights are turned o, the detector enters the shutdown countdown,
and the display is turned o from OFF 004 to OFF 000. Aer the countdown ends, the
display is turned o, and the Green indicator keep ashing for about 10 seconds,
then the instrument is turned o.
2.3 Daily use
▎Factory reset: Aer the boot process is displayed, the detector enters the facto-
ry reset interface. If you need to restore the factory sengs, press the funcon
buon twice in rapid succession, otherwise the detector will automacally enter the
main interface.
▎Main interface: The main interface is mainly used to display: gas name, gas
concentraon, alarm type, me and baery status. The green indicator ashes at this
me.
▎Fault indicaon: When the gas sensor is shorted or broken, the corresponding
detecon channel has a fault indicaon, as shown in the gure below. At this point,
the green indicator is o and the yellow fault indicator is keeps on.
Shutdown interface
Factory reset interface Main interface

12
AIYI Technologies
▎Alarm indicaon: When the gas concentraon in the environment is more than
alarm value, the detector will give an alarm. At this point, the alarm indicator ashes,
the buzzer sounds, and the detector vibrates. The STEL, TWA, alarm-1 and alarm-2
are shown below.
2.4 Operaon
▎Menu:
1.Press and hold the power buon to enter the shutdown interface,as shown in
the gure below.
2.During the shutdown countdown process, press the power and funcon buon
at the same me to enter the menu. Menu is shown in the gure below.
3.Short press the funcon buon to select the zero calibraon, span calibraon
or self-test. The selected icon will ash.
4.Press and hold the funcon buon to exit the menu interface and return to the
main interface. Main interface is shown in the gure below.
Fault indicaon (LEL channel fault)
Main interface
STEL alarm TWA alarm Alarm-1Alarm-2

13
AIYI Technologies
▎Zero calibraon:
1.Aer entering the menu, short press the funcon buon to select the zero
calibraon, the zero calibraon indicator ashes, then short press the power
buon to enter the zero calibraon interface. At this me, the zero calibraon
indicator keeps display, and the span calibraon indicator and self-test indicator
are not displayed. Zero calibraon interface is shown in the gure below.
2.Short press the funcon buon to select the specic channel, and the gas
name keep ashes.
3. Short press the power buon to do zero calibraon. If the calibraon is com-
pleted, the “End” prompt will be displayed. If the calibraon fails, the “Err”
prompt will be displayed, as shown in the gure.
4. Press and hold the funcon buon to exit the zero calibraon operaon and
return to the main interface.
Shutdown interface Menu interface Main interface
Menu interface Zero calibraon Calibraon completed Calibraon failed

14
AIYI Technologies
▎Span calibraon:
1.Aer entering the menu, short press the funcon buon to select the span
calibraon, the span calibraon indicator ashes, the zero calibraon indicator
and the self-test indicator keep displayed, then short press the power buon to
enter the span calibraon interface. At this me, the span calibraon indicator
keeps displayed, and the zero calibraon and self-test indicator are not displayed.
Span calibraon interface is shown in the gure below.
2.Short press the funcon buon to select the specic channel, and the gas
name in the selected channel ashes.
3.Short press the power buon to do span calibraon. If the calibraon is com-
pleted, the “End” prompt will be displayed. If the calibraon fails, the “Err”
prompt will be displayed, as shown in the gure.
4.Press and hold the funcon buon to exit the span calibraon and return to
the main interface.
▎Self-test:
1. Aer entering the menu, short press the funcon buon to select the self-test,
the self-test indicator ashes, the zero calibraon indicator and span calibraon
indicator keeps displayed, then short press the power buon, the detector enters
self-test.
2. The detector will display all the contents in turn, then alarm with sound, light,
vibraon once. as shown in the gure.
3.Aer the self-test is completed, back to the menu interface.
Menu interface Span calibraon Calibraon completed Calibraon failed

15
AIYI Technologies
▎Bump test:
1.Refer to indicaon diagram of calibraon adapter and the venlaon, con-
necng the calibraon adapter to the detector ghtly, and passing the gas of the
specied concentraon from the vent of the calibraon adapter.
Self-test interface Self-test interface
Menu interface Self-test interface Self-test interface

16
AIYI Technologies
2.In the main interface, press and hold the funcon buon to enter the bump
test preparaon interface. At this me, the self-test indicator ashes, short press
the power buon to enter the bump test.
3.Short press the funcon buon to select the quick detecon zone and the gas
name indicator ashes.
4.Aer a stable readings, press the power buon to enter bump test, and the gas
name ashes. About 15 seconds later, if the test is normal, the concentraon
value will ash for 3 seconds, and then the "End" prompt will be displayed. If the
test is not normal, the “Err” prompt will ash for 3 seconds, and then the gas
concentraon will be calibrated for processing. If the calibraon is successful, the
correct concentraon value will be displayed for 3 seconds, and then the “End”
prompt will be displayed. If the calibraon fails, the “Err” prompt will ash for 3
seconds, then the “End” prompt will be displayed, followed by the sensor fault as
“---”.
5.The bump test is end and the detector automacally back to the main interface.
Main interface Bump test interface
Bump test completed Bump test failed Fault indicaon

17
AIYI Technologies
2.5 Charging
There is a power indicator in the upper right corner of the display. Please keep
charge in me with original charger and cable when low power. The charging port
is a standard USB charging port. When charging, the charging indicator of the
detector keeps red, and there is also a charging prompt in the upper right corner
of the display. The charge indicator turns green when fully charged.
2.6 Data upload
In the power on state, connect the detector to the computer with the Micro USB
cable, and the computer will automacally recognize and display the correspond-
ing drive leer. Aer double-clicking on it, you can implement data export and
other operaons.
Chapter 3 Maintenance
3.1 Cauons
▎Take care to prevent the detector from falling or severe vibraon.
▎It is strictly forbidden to expose the detector to a gas with high concentraon,
corrosive gas, etc. for a long me, otherwise it will cause a serious damage to the
sensor.
▎In order to ensure the performance of the detector, calibraon should be carried
out regularly. The calibraon frequency depends on the specic working condions.
It is recommended to calibrate the detector every 3 months. The calibraon record
sheet should be lled in each calibraon. Considering if factors such as high concen-
traon impact and corrosive gases happen, it is necessary to shorten the calibraon
period. In either case, the calibraon period must not exceed one year.
▎Keep the detector clean, and if the sensor vent is blocked, it may aects the
detecon sensivity and even damage it.
Do not charge in danger areas.
Please recharge the baery before it is exhausted, or it will reduce
the baery life.

18
AIYI Technologies
▎Replace sensor in me once the sensor life is over. The replacement of the sen-
sor should be carried out under the guidance of the manufacturer or returned to
the factory for replacement.
▎Keep use the origin parts provided by manufacturer while the maintenance and
the replacement of the parts. Otherwise it may aect the performance and safety
of the instrument itself.
▎The operaon of the detector, calibraon and other maintenance work should
be carried out by qualied professionals.
▎For the faults encountered in daily maintenance, please contact the manufactur-
er in me.
3.2 Warranty
AIYI Technologies promises that the product will be guaranteed for one year from
sale and will be serviced for life. If the product fails or any problem during the use,
please feel free to contact us, we will be happy to provide you with mely and
quality service!
3.3. Trouble-Shoong
For the faults encountered during use, you can refer to the following ways to solve
the problem, or you can contact the manufacturer directly for consultaon.
Common Problems Recommended Soluons
Abnormal charging Replace the charger or cable
Readings dri Calibraon
Cannot connect to PC Replace the cable or replace the PC
Unable to boot Try reboot aer charging, or please contact the
manufacturer
Baery low alarm Stop operaon, turn o and charging
The fault light keeps on Contact the manufacturer

19
AIYI Technologies
SCIENTIFIC INNOVATION
SPECIALIZED DEDICATED
This manual suits for next models
1
Table of contents
Popular Gas Detector manuals by other brands

Dectris
Dectris EIGER 2 X 9M-V Technical specifications

mPower Electronics
mPower Electronics POLI MP400 user guide

Oppermann Regelgeräte
Oppermann Regelgeräte OPP-PIR-LUX-1 manual

Duomo
Duomo BX116 manual

Quatrosense Environmental
Quatrosense Environmental QEL Installation, operation and maintenance manual

Honeywell
Honeywell Notifier NCO-10 installation manual

Evikon
Evikon PluraSens E2638-NO user manual

Besantek
Besantek GD-3300 user manual

Consilium
Consilium ST350 Quick installation guide

MSR
MSR Intec Controls PolyGard CO LC-1112 V3 user manual

BEP
BEP 600 Series Installation and operating instructions

Henan Oceanus Import & Export
Henan Oceanus Import & Export OC-F08 operating manual