Alarmcom ADC-S40-T User manual

Temperature Sensor
Installation Guide
ADC-S40-T
Notices
FCC
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
NOTE: Changes and Modifications not expressly approved by Building 36 can void your authority to operate this
equipment under Federal Communications Commissions rules.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction, may cause harmful interference to radio communication.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following
two conditions:
1. This device may not cause interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisee aux deux conditions suivantes:
1. L’appareil ne doit pas produire de brouillage, et
2. L’appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d’en
compromettre le fonctionnement.
Radiation Exposure Statement
The device has been found to be compliant to the requirements set forth in CFR 47 Sections 2.1091 and Industry
Canada RSS-102 for an uncontrolled environment. The antenna(s) used for this transmitter must be installed to
provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in
conjunction with any other antenna or transmitter.
Le dispositif a été jugé conforme aux exigences énoncées dans les articles 47 CFR 2.1091 et Industrie Canada
RSS-102 pour un environnement non contrôle’. L’antenne(s) utilisée pour ce transmetteur doit etre installé pour
fournir une distance de séparation d’au moins 20 cm de toutes les personnes et ne doit pas être co-localisés ou
fonctionner en conjunction avec une autre antenne ou transmetteur.
Questions?
Visit answers.alarm.com
or contact your service provider.
8281 Greensboro Drive
Suite 100
Tysons, VA 22102
220111
© 2022 Alarm.com. All rights reserved.
Network LED
❺Remove the battery tab from the
sensor. When the LED on the sensor
turns solid, the sensor has been
successfully added.
❻ Ensure you see the device on
your account. This may take
up to 2 minutes.
❼ Name the device based on its
application. This can be done in
MobileTech, the Partner Portal,
or the Customer Website.
❽ Using the double-sided adhesive
tape provided, mount the sensor
on the wall.
Z-Wave Manual Installation
❶Power on the Z-Wave controller.
❷Put the Z-Wave controller into
Add mode. Refer to the Z-Wave
controller documentation for
more information.
❸Remove the battery tab from
the sensor. When the LED on the
sensor turns solid, the sensor has
been successfully added.
❹Ensure you see the device on
your account. This may take
up to 2 minutes.
❺Name the device based on its
application. This can be done in
MobileTech, the Partner Portal,
or the Customer Website.
❻ Using the double-sided adhesive
tape provided, mount the sensor
on the wall.
Troubleshooting
If the sensor is not communicating
with the Z-Wave controller
❶Slide the battery door down. The
LED should turn on and then turn
off within a few seconds.
If the LED does not happen,
the sensor cannot communicate
with the Z-Wave controller.
Follow these steps to fix the
communication problems:
a) Install a Z-Wave repeater
between the Z-Wave controller
and the sensor.
TIP: Any AC-powered Z-Wave device will
act as a repeater and improve the range
between the Z-Wave controller and the
Z-Wave device you are installing.
b) If the previous step does not resolve
the issue, try deleting the sensor
from the network (see next section)
and add it again.
Deleting the sensor from
the network
❶Put the Z-Wave controller into
Delete mode. Refer to the Z-Wave
controller documentation for
more information.
In the box
• ADC-S40-T Temperature Sensor
• CR2450 battery
• Installation guide
• Double-sided tape
Installation
The Temperature Sensor is
designed for indoor use only.
For optimal performance, install the
sensor approximately 5 feet above
the floor of an interior wall. Avoid
installing the sensor on an exterior
wall, in areas that are close to
heating or cooling vents, and areas
that are exposed to direct sunlight.
Z-Wave SmartStart Installation
❶Power on the Z-Wave controller.
❷Log in to the MobileTech app and
find the customer account.
❸Add the device using SmartStart and
follow the on-screen instructions.
❹Scan the device’s QR code found
on the box or sensor.
❷Slide the battery door down to
delete the sensor from the network.
The LED on the sensor will turn solid
and then blink to indicate the device
has been successfully deleted.
Adding the sensor to the network
❶Put the Z-Wave controller into
Add mode. Refer to the Z-Wave
controller documentation for more
information.
❷Slide the battery door down to add
the sensor to the network. When the
LED on the sensor turns solid, the
sensor has been successfully added.
Resetting the device to default
NOTE: This will remove the device from
the Z-Wave network.
❶Remove the battery door, tap the
tamper switch 3 times in a row,
press and hold the tamper switch
for 10 seconds and then release to
begin the reset to default process.
❷After the tamper switch is released,
the LED will blink quickly and then
turn solid for 3 seconds indicating
that the device is resetting.

Popular Temperature Controllers manuals by other brands

Creda GCO 233 F operating instructions

Creda

Creda GCO 233 F operating instructions

Electrothermal MC810B MKII Instruction book

Electrothermal

Electrothermal MC810B MKII Instruction book

Honeywell Satellite Receiver installation guide

Honeywell

Honeywell Satellite Receiver installation guide

HANYOUNG NUX DX Series instruction manual

HANYOUNG NUX

HANYOUNG NUX DX Series instruction manual

Delta DTB4824 instruction sheet

Delta

Delta DTB4824 instruction sheet

AutomationDirect SOLO SL4896 Series quick start guide

AutomationDirect

AutomationDirect SOLO SL4896 Series quick start guide

Thermo Solar SR14 Installation and operating instructions

Thermo Solar

Thermo Solar SR14 Installation and operating instructions

Avtech Room Alert 32W User guide and reference manual

Avtech

Avtech Room Alert 32W User guide and reference manual

Aqua Medic T 2001 CC Operation manual

Aqua Medic

Aqua Medic T 2001 CC Operation manual

Bitron Video AV2010/27A quick start guide

Bitron Video

Bitron Video AV2010/27A quick start guide

Ink Bird ITC-1000 manual

Ink Bird

Ink Bird ITC-1000 manual

Samwontech SU-105DA-N user manual

Samwontech

Samwontech SU-105DA-N user manual

AutomationDirect SOLO quick start guide

AutomationDirect

AutomationDirect SOLO quick start guide

Lake Shore 340 user manual

Lake Shore

Lake Shore 340 user manual

AutomationDirect SL4848-RR quick start guide

AutomationDirect

AutomationDirect SL4848-RR quick start guide

Technoline WS9250 User instruction

Technoline

Technoline WS9250 User instruction

JSP FlexiTEMP 60 manual

JSP

JSP FlexiTEMP 60 manual

MULTISPAN UTC-4203 operating manual

MULTISPAN

MULTISPAN UTC-4203 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.