MC 740-E-M14 Instruction Manual 4-MC740-E-M14-01
© 2020 Alarmtech Rev. MC740-E-M14_2048en Page 2of 2
INSTALLATION
Depending on the application, contact and magnet should be
installed in either front-to-front or side-to-front
configuration. Installation drawings show the correct
positioning of the contact parts. The contact should be
mounted on the stationary part of the monitored object (ex.
door frame) and the magnet on the movable part (ex. door
leaf, roller-shutter).
During installation of contact part of MC 740-PE-M14 in
window or door frame, it is advised to leave additional cable
loop for about 10cm long.
After the installation, use an ohmmeter to check the electrical
connections and test the operation of the magnetic contact.
Warning: applying excessive force to the housing of the
contact may damage the glass body of the reed switches
inside.
Warning: installation in ferromagnetic environment is not
recommended.
INSTALLATION DRAWINGS
For optimal working distance of the reed switch the magnet
should be placed in a vertical position above the screw hole
of the contact part.
MC 740-E-M14 / MC 740-PE-M14 in front to front
configuration
MC 740-E-M14 / MC 740-PE-M14 in side to front
configuration