Alcatel-Lucent 9500 MPR Instructions for use

9500 MPR
Installation Practices
PN 3EM23953AB 01
R01.02, Issue 01, February 2010

©Alcatel-Lucent 2010 - All Rights Reserved
Printed in U.S.A.
THIS PRODUCT COMPLIES WITH D.H.H.S. RADIATION PERFORMANCE STANDARDS 21
CFR, 1040.10, FOR A CLASS 1 LASER PRODUCT.
DANGER
Invisible laser radiation is present when the optic connector is open. AVOID DIRECT
EXPOSURE TO BEAM.
WARNING
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case users will be required to correct the
interference at their own expense.
NOTICE
This manual applies to 9500 MPR R01.02 software. Release notes describing revisions to this software may
impact operations described in this manual.
This transfer of commodities, technology, or software, if from the United States, is an export in accordance
with the U.S. Export Administration Regulations. Diversion contrary to U.S. law is prohibited. The export or
re-export (further transfer) of such commodities, technology, software or products made from such
technology is prohibited without proper authorization(s) from the U.S. Department of Commerce or other
appropriate U.S. government agency(s).
All rights reserved. No part of this manual may be reproduced, translated, stored in a retrieval system, or
transmitted or distributed by any means, electronic or mechanical, by photocopying, recording, or otherwise,
without the written permission of Alcatel-Lucent. Preparing derivative works or providing instruction based
on the material is prohibited unless agreed to in writing by Alcatel-Lucent.
The product specification and/or performance levels contained in this document are for information
purposes only and are subject to change without notice. They do not represent any obligation on the part of
Alcatel-Lucent. Such obligations will only be committed to in a written sales agreement signed by
Alcatel-Lucent.
DOCUMENTATION
Product documentation is available on Alcatel-Lucent’s OnLine Customer Support web site at
https://support.alcatel-lucent.com/portal/olcsHome.do.
To offer comments on this documentation, visit Alcatel-Lucent’s OnLine Customer Support web site at
https://support.alcatel-lucent.com/portal/olcsHome.do and select Contact us, Customer support, and then
OnLine Assistance or write to the following address.
Alcatel-Lucent
Attention: Doc Comment, M/S RND-1
3400 W. Plano Pkwy.
Plano, Texas 75075-0811 USA

3EM23953AB
Issue 01, February 2010
© Alcatel-Lucent 2010 - All Rights Reserved i
ALCATEL-LUCENT PRACTICE
Standard
9500 MPR Installation Practices
Table of Contents
Charts
Chart-1 Unpack and Inspect Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Chart-2 Prepare Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Chart-3 Rack Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
Chart-4 PDU Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-27
Chart-5 Route and Terminate Station Ground and Office Battery Power Cables . . . . . . . . . . . 1-31
Chart-6 MSS-8 Shelf Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-39
Chart-7 Route and Terminate 9500 MPR Shelf Power Cables. . . . . . . . . . . . . . . . . . . . . . . . . 1-43
Chart-8 Type N Adapter Bracket Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-49
Chart-9 DS1 Patch Panel Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-51
Chart-10 Integrated Antenna and ODU Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-59
Chart-11 Non-Integrated Antenna and ODU Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-75
Chart-12 IF Cable System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-85
Chart-13 Lightning Surge Suppressor Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-91
Chart-14 IF Cable System Grounding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-105
Chart-15 Weatherproofing Coaxial Cable Connectors and Cable Grounds . . . . . . . . . . . . . . . 1-109
Chart-16 Route and Terminate DS1 Signal Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-113
Chart-17 Route and Terminate DS3 Signal Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-121
Chart-18 Route and Terminate Ethernet Signal Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-125
Chart-19 Route and Terminate Sync Signal Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-131
Chart-20 Route and Terminate Fan Office Alarm Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-133
Chart-21 Install Standoffs and Secure Cables with Cable Ties . . . . . . . . . . . . . . . . . . . . . . . . 1-137

3EM23953AB
Issue 01, February 2010
Table of Contents
ii
Chart-22 Assembly CSM to PC Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-141

3EM23953AB
Issue 01, February 2010
List of Figures iii
9500 MPR Installation Practices
List of Figures
Figure 2-1. Sample Floor Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Figure 2-2. Floor Mounting Detail for Standard Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Figure 2-3. Floor Mounting Detail for Unequal Flange Seismic Rack. . . . . . . . . . . . . . . . . . . . . . . . 1-7
Figure 2-4. Standard Rack (PN 694-9000-006) (1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Figure 2-5. Standard Rack (PN 694-9000-006) (2 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Figure 2-6. Unequal Flange Seismic Rack (PN 1AD014120046). . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Figure 2-7. Self-Drilling Anchor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Figure 2-8. Anchor Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
Figure 3-1. Securing Rack to Floor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17
Figure 3-2. Standard Rack Top Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19
Figure 3-3. Standard Rack Top with Extension Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20
Figure 3-4. Seismic Rack Top Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21
Figure 3-5. Typical Method of Bracing Top Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22
Figure 3-6. Guardrail Installation, Standard Racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24
Figure 3-7. Adjacent Rack Attachment, Standard Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-25
Figure 4-1. PDU Mounting Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-28
Figure 4-2. PDU Mounting Detail with Existing Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-29
Figure 5-1. PDU Strap Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32
Figure 5-2. Station Ground Standard Rack Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33
Figure 5-3. Station Ground Seismic Rack Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33
Figure 5-4. Station Ground Crimp Lug Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34
Figure 5-5. Wire Sizing Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35

3EM23953AB
Issue 01, February 2010
List of Figures
iv
Figure 5-6. PDU Battery Interconnect Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-36
Figure 5-7. PDU Office Battery Routing Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-37
Figure 6-1. MSS-8 Shelf Mounting Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-40
Figure 6-2. 9500 MPR Shelf Screw Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-41
Figure 7-1. MSS-8 Shelf Power Connection Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-44
Figure 7-2. Power Cable Connection to MSS-8 Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-44
Figure 7-3. Power Cable Routing Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-45
Figure 7-4. B-Side Power to PDU Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-45
Figure 7-5. A-Side Power to PDU Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-46
Figure 7-6. Power Cable Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-47
Figure 7-7. Power Cable Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-47
Figure 8-1. Type N Adapter Bracket Mounting Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-50
Figure 8-2. Type N Jumper Cable Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-50
Figure 9-1. DS1 RJ-45 Patch Panel Mounting Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53
Figure 9-2. DS1 Patch Panel Cable Routing, Front View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-54
Figure 9-3. DS1 Patch Panel Cable Routing, Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-55
Figure 9-4. DS1 37 Pin D Patch Panel and Rack Mount Bracket Detail . . . . . . . . . . . . . . . . . . . . 1-56
Figure 9-5. DS1 37 Pin D Patch Panel Mounting Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-56
Figure 10-1. Integrated Antenna Mount Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-68
Figure 10-2. Integrated Antenna Mount Detail Continued . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-69
Figure 10-3. Integrated Antenna Attached to Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-69
Figure 10-4. Integrated Antenna Polarization Setting Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-70
Figure 10-5. ODU Polarization Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-71
Figure 10-6. ODU Mounting Hardware Detail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-72

3EM23953AB
Issue 01, February 2010
List of Figures v
Figure 10-7. ODU Attached to Integrated Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73
Figure 11-1. Remote ODU Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-79
Figure 11-2. Remote ODU Mount Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-80
Figure 11-3. Integrated Antenna Polarization Setting Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-81
Figure 11-4. Coupler Polarization Detail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-82
Figure 11-5. Installed Coupler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-83
Figure 12-1. Typical Tower Coaxial Cable Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-86
Figure 13-1. Typical Tower Coaxial Cable and Lightning Surge Suppressor Grounding Detail. . . . 1-92
Figure 13-2. Surge Suppressor Installed Inside Building . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-94
Figure 13-3. Surge Suppressor Installed Outside Building. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-95
Figure 13-4. Surge Suppressor with Right-Angle Connector Alignment Detail . . . . . . . . . . . . . . . . 1-96
Figure 13-5. Suppressor and Connector Covered with Amalgamating Tape Detail. . . . . . . . . . . . . 1-97
Figure 13-6. Suppressor and Connector Covered with UV-Protecting Vinyl Tape Detail. . . . . . . . . 1-97
Figure 13-7. ODU with Suppressor Assembly Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-98
Figure 13-8. ODU with Suppressor Assembly with Amalgamating Tape . . . . . . . . . . . . . . . . . . . . . 1-99
Figure 13-9. ODU with Suppressor Assembly weatherproofed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-99
Figure 13-10. Suppressor Support Bracket with No-Ox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-100
Figure 13-11. Suppressor with Ground Wire Attached. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-101
Figure 13-12. Suppressor with Ground Wire Looped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-101
Figure 13-13. Completed Antenna, ODU, and Surge Suppressor Assembly. . . . . . . . . . . . . . . . . . 1-103
Figure 14-1. Typical Tower Coaxial Cable Grounding Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-106
Figure 14-2. Typical Radio Coaxial Cable Grounding Outside Building . . . . . . . . . . . . . . . . . . . . . 1-107
Figure 14-3. Radio Coaxial Cable Grounding, Surge Suppressor Inside Building . . . . . . . . . . . . . 1-107
Figure 16-1. RJ-45 Patch Panel Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-115

3EM23953AB
Issue 01, February 2010
List of Figures
vi
Figure 16-2. DS1 37 Pin DSUB Customer Interconnect Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-116
Figure 16-3. P32E1DS1 68 Pin SCSI Connector Front Panel View. . . . . . . . . . . . . . . . . . . . . . . . 1-118
Figure 17-1. P2DS3E Front Panel Connector Interconnect Detail . . . . . . . . . . . . . . . . . . . . . . . . . 1-122
Figure 17-2. DS3 Hybrid Splitter Interconnect Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-124
Figure 18-1. CSM Customer Interconnect Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-128
Figure 19-1. CSM Card Sync In and Out Interconnect Detail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-132
Figure 20-1. FAN Office Alarm and Control Customer Interconnect Detail . . . . . . . . . . . . . . . . . . 1-135
Figure 21-1. Example Cable secured to Standoff. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-138
Figure 21-2. MSS-8 Shelf Left Side Cable Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-139
Figure 21-3. MSS-8 Shelf Right Side Cable Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-139

3EM23953AB
Issue 01, February 2010
List of Tables vii
9500 MPR Installation Practices
List of Tables
Table 2-A. Rack Type and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Table 7-A. PDU Power Cable Termination Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-46
Table 10-A. Integrated Antenna Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-60
Table 10-B. ODU Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-61
Table 10-C. ODU Coupler Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-67
Table 11-A. Waveguide Flange Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-76
Table 11-B. ODU Mount and Flexible Waveguide Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-77
Table 11-C. ODU Coupler Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-78
Table 16-A. RJ-45 Patch Panel Cable Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-115
Table 16-B. 37 Pin D-Sub Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-116
Table 16-C. 68 Pin SCSI Cable Output (XMT) Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-118
Table 16-D. 68 Pin SCSI Cable Input (RCV) Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-119
Table 18-A. 10/100 BaseT Ethernet RJ-45 Cable Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-129
Table 18-B. 1000 BaseT Ethernet RJ-45 Cable Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-129
Table 20-A. Fan Card Office Alarm and Control Connector / Cable Detail . . . . . . . . . . . . . . . . . . 1-134
Table 22-A. NMS Cable Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-141

3EM23953AB
Issue 01, February 2010
List of Tables
viii

3EM23953AB
Issue 01, February 2010
Unpack and Inspect Equipment 1-1
Chart-1
Charts
Chart-1
Unpack and Inspect Equipment
PURPOSE
This chart provides instructions to unpack and inspect the 9500 MPR radio and to report any
shipping damage or missing parts.
GENERAL
The 9500 MPR radio may be shipped from the factory as an assembled rack assembly or as kits for
field installation.
Alcatel-Lucent provides expert Installation Services for installations that have different
requirements from the recommended configuration as outlined in this manual. Contact the
Alcatel-Lucent Technical Support Center at 1-(888) 252-2832 for details.
RECOMMENDED TOOLS
•Tin snips
•Box cutter
STEP PROCEDURE
1 DANGER: Possibility of personal injury. The 9500 MPR radio requires two people to
unpack a factory assembled rack assembly from the box. To prevent equipment
damage or personal injury, make sure appropriate help or suitable lifting equipment
is available if needed.
2WARNING: Possibility of equipment damage. If product must be transported
or reshipped, repack equipment with approved shipping materials.
Repacking equipment improperly or using unapproved shipping materials
may result in equipment damage, which is sender’s responsibility. If any
shipping materials are lost, contact Alcatel-Lucent before transporting or
reshipping product.
3Remove external packing slip from shipping container.
4Before unpacking container, ensure there is no visible damage to outside of container.
If damage is visible, report damage to freight carrier before opening container. Freight
carrier will advise as to next step to take. (If a camera is available, take several
pictures of damage.)
5Use tin snips to cut container strapping.

3EM23953AB
Issue 01, February 2010
Unpack and Inspect Equipment
1-2
Chart-1
6If necessary, unstack boxes onto a level surface.
7Open top flaps of all boxes.
8In box containing MSS-8 shelf, remove shelf from box.
9Remove fan and modules, excluding filler panels, from shelf. Place modules into
antistatic bags or containers to prevent module damage.
10 Remove shelf from box, removing any additional packing material covering shelf.
Place shelf onto a level surface.
11 Inspect MSS-8 shelves and their card cage area for visible damage. If damage is
visible, contact Alcatel-Lucent to report damage and to find out what to do next.
12 Inspect contents of box containing accessories for damage or missing parts.
13 To report damage or missing parts, contact Alcatel-Lucent Technical Support Center
at 1-(888) 252-2832.
14 STOP. This procedure is complete.

3EM23953AB
Issue 01, February 2010
Prepare Floor 1-3
Chart-2
Chart-2
Prepare Floor
PURPOSE
This chart details the standard procedure for rack installation floor preparation. The two types of
racks that can be installed are the standard rack and the seismic.
GENERAL
Equipment racks are designed for fixed-location installation. Standard and seismic rack assemblies
are available.
Alcatel-Lucent provides expert Installation Services for installations that have different
requirements from the recommended configuration as outlined in this manual. Contact the
Alcatel-Lucent Technical Support Center at 1-(888) 252-2832 for details.
PREREQUISITE
Complete Chart-1Unpack and Inspect Equipment.
RECOMMENDED TOOLS
•Safety glasses
•Anchor setting tool (Redhead RT58 or equivalent)
•Chalk line with chalk
•Extension cord (50-foot)
•Felt marking pens
•Hammer, claw (24 to 40 ounces)
•Roll of cellophane tape
•Rotary impact drill and associated drill bits
•Steel tape measure (25-foot)
•Insulated trouble lamp (droplight—Duralamp, or equivalent)
•Vacuum cleaner, High Efficiency Particulate Arrester (HEPA)

3EM23953AB
Issue 01, February 2010
Prepare Floor
1-4
Chart-2
STEP PROCEDURE
1Observe the following guidelines:
a. Verify that layouts of floor, ceiling, and walls are as indicated in applicable
drawings and specifications.
b. Verify that area dimensions and location of reference points correspond to floor
plan.
c. Mark all reference and layout lines.
d. To avoid possibility of cumulative errors when short dimensions are laid out in a
straight line, mark total length, divide into shorter lengths, and leave steel
measuring tape in place.
e. Where layout lines intersect, extend lines at least 6 in. beyond point of
intersection to check equipment alignment.
NOTE: When the shelf assembly is mounted in a rack next to a wall, clearance from
the backplane requires a minimum of six inches.
2WARNING: Possibility of equipment damage. Use a level to check entire
mounting floor space. Do not try to mount rack on uneven floor.
3Follow job floor plan, and mark equipment locations on floor with chalk line. See
figure 2-1 for sample floor plan.rack footprint.

3EM23953AB
Issue 01, February 2010
Prepare Floor 1-5
Chart-2
4Verify required space for rack. See figure 2-1.
5Follow chalk line to mark front baseline and end of rack.
6Use felt-tipped marking pen to mark anchor points for rack.
See Figure 2-2, floor mounting diagram for standard rack. See Figure 2-3, floor
mounting diagram for seismic rack.
Figure 2-1. Sample Floor Plan

3EM23953AB
Issue 01, February 2010
Prepare Floor
1-6
Chart-2
Figure 2-2. Floor Mounting Detail for Standard Rack
950-0202-1
022610
C
L
20.50
4.26
16.378
8.19
11.27
5.25
2.75
5.25
.5620 DIA
4 HOLES
Floor Mounting Pattern
Rear Baseplate Shown
Turned out

3EM23953AB
Issue 01, February 2010
Prepare Floor 1-7
Chart-2
7Determine rack type, refer to Table 2-A. See Figure 2-4 and Figure 2-5 for standard
rack assembly mounting dimensions. See Figure 2-6 for seismic rack assembly
mounting dimensions.
Figure 2-3. Floor Mounting Detail for Unequal Flange Seismic Rack
Table 2-A. Rack Type and Options
PART NUMBER DESCRIPTION QTY
694-9000-006 7.0 Ft. Aluminum Rack 1
690-1125-003 Rack Extension 1
695-1001-006 Aluminum Rack Screw Kit (for EFE) 1 or 2
1AD014120046 7.0 Ft. Seismic Rack 1
695-1001-006 Rack Screw Kit (for Shelf & EFE) 1 or 2
950-0203-1
022610
45
o
4.0
4 Slots
1” x 2.75”
2 Slots
1.625” x 3.1875 5.05
5.88
5.0
Front Mounting
Surface of
Rack Channel
Floor Mounting Pattern
Unequal Flange Seismic Rack
21.9375
11.8438
10.1875
2.8125

3EM23953AB
Issue 01, February 2010
Prepare Floor
1-8
Chart-2
Figure 2-4. Standard Rack (PN 694-9000-006) (1 of 2)

3EM23953AB
Issue 01, February 2010
Prepare Floor 1-9
Chart-2
Figure 2-5. Standard Rack (PN 694-9000-006) (2 of 2)

3EM23953AB
Issue 01, February 2010
Prepare Floor
1-10
Chart-2
Figure 2-6. Unequal Flange Seismic Rack (PN 1AD014120046)
950-0207-1
022610
84.00
Standard
Height
See
Rack Grounding
Detail
(2 Places)
21.9375”