Alderon Industries Mini Power Post PRPT-00003 User manual

USER GUIDE
MODEL NUMBER:
PRPT-00003
Mini Power Post™
Pump Connection Center

Contents
Introduction................................................................................................................................................................. 3
Safety Guidelines ................................................................................................................................................... 3
Included with Post .................................................................................................................................................. 4
Features ................................................................................................................................................................. 5
Installation .................................................................................................................................................................. 6
Installing Post..................................................................................................................................................... 6, 7
Wiring..................................................................................................................................................................7, 8
General Operation...................................................................................................................................................... 9
Septic Tank Monitoring........................................................................................................................................... 9
Alarm Auxiliary with Auto Dialer........................................................................................................................... 10
Troubleshooting ........................................................................................................................................................ 11
Specications ........................................................................................................................................................... 12
Warranty Information ................................................................................................................................................ 13
Company Information ............................................................................................................................................... 16
Mini Power Post™ - USER GUIDE

Alderon Industries™ - Leading Edge Control Products | 3
Mini Power Post™ - USER GUIDE
Introduction
Use the Mini Power Post™ to make a professional and safe connection for power and oat switch wiring connections to your
on-site septic system. The Mini Power Post™ eliminates a 4" x 4" wood post and the exposed wires for a safe, clean, and quick
installation. The Mini Power Post™ serves as a junction box which is connected to a remote alarm panel. This system can be
used for a wide variety of applications, including but not limited to: septic tanks, holding tanks, pump chambers, and water tanks.
Visit our website alderonind.com to view the different options and accessories. In addition, there are a variety of oat switches
that can be used with the Mini Power Post™.
Safety Guidelines
Before proceeding with the installation or operation of this product, read all instructions thoroughly, as well as complying with
all federal, state and local codes, regulations, and practices. This product must be installed by qualied personnel familiar with
all applicable local electrical and mechanical codes. Refer to the National Electrical Code (NFPA 70). Failure to properly install
and test this product can result in personal injury or equipment malfunction.
WARNING
1. DISCONNECT POWER when installing or servicing the product. Failure to disconnect all power sources could result in
serious injury or death.
2. NEVER enter a ooded space without proper Personal Protective Equipment (PPE). Always wear dielectric rubber boots
and other applicable protective equipment when water is on the oor and you must service an energized pump, alarm
system, or product.
3. DO NOT enter the water if the water level is higher than that of the protection your PPE offers or if your PPE is not
watertight.
4. DO NOT use this product with or near ammable liquids.
5. DO NOT install this product in locations classied as hazardous or in explosive atmospheres as dened by any applicable
electrical safety code.

4 | Alderon Industries™ - Leading Edge Control Products
Mini Power Post™ - USER GUIDE
Included with Post
This model includes: (1) Mini Power Post™ with junction box, (1) Pump Power Receptacle (120VAC or 230VAC depending on
part number), and (5) Wago connectors.
ADDITIONAL OPTIONS:
(4) Versa’larm™ Indoor Alarm Panel
The Versa’larm™ indoor alarm has options for monitoring one
to three zones (sensors).
(5) Alarm Float Switch
The alarm oat switch is a typical sensor expected to be used
with the Versa’larm™ indoor alarm for liquid level monitoring.
(6) Pump Float Switch
The pump oat switch is used to control the pump directly. When
actuated the pump oat switch will pass power to the pump. 6
5
4
(1) Mini Power Post™
The Mini Power Post™ comes with a 42.5-inch post to install in
the ground. The ventilated post cap, cable grips, and junction
box are all pre-installed to the post.
(2) Pump Power Receptacle (120VAC shown)
A female, 15A, pump power receptacle is pre-installed (120VAC
or 230VAC depending on part number).
(3) Wago Connector
Five Wago connectors are included. Three are pre-installed
on the pump power receptacle. Then there are two additional
Wago connectors for the alarm oat connections.
1
3
2
(120VAC Model Shown, 230VAC Models Available)

Alderon Industries™ - Leading Edge Control Products | 5
Mini Power Post™ - USER GUIDE
Features
Refer to the illustration below to reference the feature descriptions provided.
(1) Vented Post Cap - Allows airow to prevent the build up of gases
and condensation inside the post.
(2) Junction Box Enclosure - Pre-installed on post for easy wiring
and installation.
(3) Cable grips - Pre-installed, making it easy to run wire in and out
of the enclosure.
(4) Partition - Separates high voltage from low voltage.
3
1
6
2
3
4
(5) Pump Power Receptacle (not shown) - A female, 15A, pump
power receptacle is pre-installed (120VAC or 230VAC depending on
part number).
(6) Post - Provides wire routing access to the pre-installed junction
box and protection from water intrusion.
(7) QR Code (not shown) - Scan code on bottom enclosure cover
which directs you to alderonind.com where additional information can
be found for the Mini Power Post™.

6 | Alderon Industries™ - Leading Edge Control Products
Mini Power Post™ - USER GUIDE
21 4 53
Installing Post
1 2 3 4 5
Installation
STEP 1: INSTALL POST
Determine the location for the post in the ground near a tank.
Drill access holes for the oat switch cables using the customer
supplied conduit/ttings or Alderon’s riser connection kit (refer
to step 2 below).
Note: Seal all conduits to prevent moisture and gases from
entering the post per local codes.
DISCONNECT ALL POWER SOURCES WHEN INSTALLING OR SERVICING THIS PRODUCT. FAILURE TO
TURN OFF ALL POWER SOURCES COULD RESULT IN SERIOUS INJURY OR DEATH.
STEP 2: INSTALLING AN ALDERON RISER CONNECTION KIT
1. Determine location for access hole on the post. Drill access hole for the correct size terminal adapter (2.0" or 2.5" depending
on model / #2). Insert terminal adapter into access hole. On the inside of the post, use the lock nut (#1) to secure the terminal
adapter in place (use PVC cement to ensure proper bonding between the terminal adapter and post per local codes).
2. Insert PVC pipe (conduit / #3) into terminal adapter using appropriate cement for bonding.
3. Determine location on the riser to insert the conduit (2.0" or 2.5" depending on model). If your riser does not have a
pre-drilled hole for the conduit, you must drill a hole in the riser to accept the conduit. Insert conduit through the riser hole,
which is now attached with the post. Seal conduit to riser hole with silicone or per local codes.
4. Run the pump power, pump oat switch, and alarm oat switch cables through the PVC coupler (#5). Then continue through
the conduit and to the appropriate height inside the post for wiring. Take the 3-hole rubber grommet (#4) which has slits
next to the holes and insert cables, then insert the rubber grommet into the conduit.
5. Place the PVC coupler over the end of the conduit.

Alderon Industries™ - Leading Edge Control Products | 7
Mini Power Post™ - USER GUIDE
Wiring
STEP 1: WIRING CONNECTIONS
1) Route alarm oat switch cable through Cable Grip A and
rmly tighten grip.
2) Route the underground feeder (UF) cable from the
indoor alarm panel through Cable Grip B and rmly
tighten grip.
3) Route incoming pump power UF cable through Cable
Grip D and rmly tighten grip.
4) Connect wires in Cable Grip D to the pre-installed Wago
connectors on wires coming out of Cable Grip C as shown
in the diagram.
5) Connect wires coming in Cable Grip A to wires coming in
Cable Grip B as shown in the diagram.
Note: NEVER leave ground wire exposed, use provided Wago
connectors for wire termination.
Installing Post (continued)
STEP 2: INSTALLING WIRE INTO WAGO CONNECTOR
1) Lift tab(s) upward.
2) Insert wire(s) into slot.
3) Press tab(s) downward.
4) Make sure wire(s) are secured.
STEP 3: REMOVE BOTTOM COVER
The bottom enclosure cover is fastened by a single screw on
the bottom of the enclosure. Remove the screw and slide the
cover directly downward (3A) and pull directly away from the
enclosure (3B).
3A 3B
WAGO
A
GREEN
BLACK
WHITE
BLACK
B
L
A
C
K
B
L
A
C
K
W
H
I
T
E
W
H
I
T
E
WHITE
GROUND
B
C
D
WAGO WAGO
WAGO
WAGO
TO OPEN
WAGO TO CLOSE
WAGO

8 | Alderon Industries™ - Leading Edge Control Products
Mini Power Post™ - USER GUIDE
Wiring (continued)
STEP 4: BACKFILL
Once all steps of the installation and wiring are complete, take
the dirt/soil removed and backll the area you dug for the post
and riser.
Backll
Area
Backll
Area
STEP 3: INSTALL BOTTOM COVER
Place the bottom of enclosure back on, lining up with the
grooves (3A). Then slide the bottom piece upward (3B) until it
meets the top piece and screw hole is lined up with the boss.
Replace the screw at the bottom of the enclosure.
3B3A

Alderon Industries™ - Leading Edge Control Products | 9
Mini Power Post™ - USER GUIDE
Testing the Wire Connections
Make sure the installation process is completed and there is power to the product.
STEP 1: PUMP FLOAT SWITCH
Activate the pump oat switch and the pump should turn on, when the pump oat switch deactivates the pump should turn off.
STEP 2: ALARM FLOAT SWITCH
Activate the alarm oat switch, the alarm indicator of the indoor alarm should illuminate and the buzzer should annunciate.
When the alarm oat switch is deactivated, the indoor alarm should reset for the next alarm cycle.
STEP 3: ADDITIONAL TESTING
Make sure to follow all individual instructions for the indoor alarm, pump oat switch, alarm oat switch, or accessories for any
additional testing.

10 | Alderon Industries™ - Leading Edge Control Products
Mini Power Post™ - USER GUIDE
General Operation
The Mini Power Post™ serves as a junction box for easy wire access. The junction box allows for easy connection of pump
power, pump oat switch, and high level alarm oat switch which is connected to the remote alarm panel. The junction box can
be used for a wide variety of applications. The applications are not limited to what is listed in this user guide. Follow all individual
instructions for oat switches and accessories used with the Mini Power Post™.
The following applications can be found in this user guide: Septic Tank Monitoring and Alarm Auxiliary with Auto Dialer.
Septic Tank Monitoring
The diagram below displays the typical setup for septic tank monitoring. The setup includes: Mini Power Post™, Versa’larm™
indoor alarm, alarm oat switch, and pump oat switch. The Mini Power Post™ is installed into the ground and attached to
the septic tank riser. The pump oat switch is only wired to the pump power line. When the pump oat switch is actuated, the
pump will turn on and turn back off when the pump oat switch is deactivated. The alarm oat switch is wired through the post
and extends to the remote alarm in the house. When the alarm oat switch is actuated, the Versa’larm™ alarm indicator will
illuminate and the buzzer will annunciate. The alarm condition will stay on until the alarm oat switch is deactivated. If the alarm
silence pushbutton of the Versa’larm™ is pressed during an alarm condition, then the alarm indicator will remain on and the
buzzer will silence. The indoor alarm will reset when the alarm oat switch connected to the Mini Power Post™ deactivates. The
Versa’larm™ in the house provides a local audible and visual alarm indication in a convenient indoor location.
5:05
PM 71%
REGENERATION
MENU ENTER
Septic to Drain Field
House to Septic
Mini
Power
Post™
Alarm
Float
Pump
Switch
Versa’larm™
Indoor Alarm

Alderon Industries™ - Leading Edge Control Products | 11
Mini Power Post™ - USER GUIDE
Alarm Auxiliary with Auto Dialer
The diagram below displays the typical setup for septic tank monitoring with a local alarm and auto dialer. The setup includes:
Mini Power Post™, Versa’larm™ indoor alarm, alarm oat switch, pump oat switch, and auto dialer. The Mini Power Post™ is
installed into the ground and attached to the septic tank riser. The pump oat switch is only wired to the pump power line. When
the pump oat switch is actuated, the pump will turn on and turn back off when the pump oat switch is deactivated. The alarm
oat switch is wired through the post and extends to the remote alarm in the house. When the alarm oat switch is actuated,
the Versa’larm™ alarm indicator will illuminate, the buzzer will annunciate, and the auxiliary contacts close activating the input
of the auto dialer sending a message to programmed number(s). The alarm condition will stay on until the alarm oat switch is
deactivated. If the alarm silence pushbutton of the Versa’larm™ is pressed during an alarm condition, then the alarm indicator
will remain on and the buzzer will silence. The indoor alarm will reset when the alarm oat switch connected to the Mini Power
Post™ deactivates. The secondary power supply in the Versa’larm™ is used to power the auto dialer. The Versa’larm™ in the
house provides a local audible and visual alarm indication in a convenient indoor location, plus the auto dialer will remotely
notify the programmed number(s).
5:05
PM 71%
REGENERATION
MENU ENTER
Auto
Dialer
Septic to Drain Field
House to Septic
Mini
Power
Post™
Alarm
Float
Pump
Switch
Versa’larm™
Indoor Alarm

12 | Alderon Industries™ - Leading Edge Control Products
Mini Power Post™ - USER GUIDE
Specications
Enclosure:
Certications:
Outdoor, rated Type 3R
CSA (US and Canada)
Pump Power Receptacle:
Pump Power:
120VAC or 230VAC, 15A, 60 Hz (voltage depends on model/part number)
120VAC or 230VAC, 13A or 15A, 60 Hz (voltage/amps depends on model/part number)
NUMBER CATEGORY TYPE / EXAMPLE
1Base Model SMP = Mini Power Post™ Standard, Demand Dose
2Pump Voltage 1 = 120VAC Pump
2 = 230VAC Pump
3Alarm Options
X = No Alarm Option
5 = 1-Zone Indoor Alarm and 15' Alarm Float
6 = 1-Zone Indoor Alarm and 20' Alarm Float
7 = 1-Zone Indoor Alarm, 15' Alarm Float, and 15' Filter Switch
8 = 1-Zone Indoor Alarm, 20' Alarm Float, and 20' Filter Switch
9 = 2-Zone Indoor Alarm, 15' Alarm Float, and 15' Filter Switch
9A = 2-Zone Indoor Alarm, 20' Alarm Float, and 20' Filter Switch
4Pump Switch Options
(piggyback plug models)
X = No Pump Switch Option
1C = 13 Amp, 15' Medium Angle Pump Switch
2C = 13 Amp, 15' Wide Angle Pump Switch
4C = 13 Amp, 20' Medium Angle Pump Switch
5C = 13 Amp, 20' Wide Angle Pump Switch
1B = 15 Amp, 15' Medium Angle Pump Switch
2B = 15 Amp, 15' Wide Angle Pump Switch
3B = 15 Amp, 15' DoubleMax™ 2-Float Pump Switch
4B = 15 Amp, 20' Medium Angle Pump Switch
5B = 15 Amp, 20' Wide Angle Pump Switch
6B = 15 Amp, 20' DoubleMax™ 2-Float Pump Switch
5Riser Kit and Access Panel
Options
X = No Riser Kit or Access Panel Option
1 = 2.0" Riser Connection Kit
2 = 2.5" Riser Connection Kit
X1 = No Riser Kit with Access Panel
11 = 2.0" Riser Connection Kit with Access Panel
21 = 2.5" Riser Connection Kit with Access Panel
Example Shown: Mini Power Post™ Standard, 120VAC, 1-Zone Indoor Alarm, 15' Alarm Float, 15' Filter Switch, 15A 15' Wide Angle Pump
Switch, 2.5" Riser Connection Kit
Model Number Nomenclature
SMP172B2
1 2 3 4 5

Alderon Industries™ - Leading Edge Control Products | 13
Mini Power Post™ - USER GUIDE
Warranty Information
LIMITED WARRANTY: Subject to the conditions of this Three-Year Limited Warranty, Alderon Industries, LLC (“Alderon”) war-
rants to the original user or consumer of an Alderon product (the “Product”) that, for a period of three (3) years from the date of
manufacture, the Product will be free from defects in materials and workmanship under normal use and service, and provided
the Product is installed, operated and maintained in accordance with instructions supplied by Alderon.
WARRANTY EXCLUSIONS: Notwithstanding anything to the contrary, this Limited Warranty does not cover:
1. Alderon custom control units. Please see the One-Year Limited Warranty – Custom Controls.
2. Damage, defects or malfunctions resulting from (a) failure to properly install, operate or maintain the Product in accordance
with printed instructions provided and with applicable local codes, ordinances and good trade practices; (b) normal wear and
tear; (c) abuse, accident or negligence; (d) de-installation and movement of the Product from its original installation location;
(e) repair and/or modication of the Product without prior authorization from Alderon; (f) use of the Product for purposes other
than for what it was designed and manufactured; or (g) conditions beyond the control of Alderon, including lightning and freight
damages (hidden or visible). Contact parcel or the freight company for claims on freight damage in transit.
3 Cost of eld labor or other charges incurred by you in removing and/or re-afxing the Product or any part or component
thereof.
4. Transportation costs.
CLAIM PROCEDURE: To make a claim regarding breach of warranty, (a) the claim must be received by Alderon before the ex-
piration of the warranty period; and (b) the defective Product, or part thereof, must be returned to a designated Alderon location,
FREIGHT PREPAID, together with proof of purchase. A return goods authorization must be received prior to the return of the
defective Product or part. Please contact the sales representative in your area to determine the designated Alderon location for
return and to obtain the return goods authorization. If you do not have a sales representative in your area, please call 218-483-
3034 to submit your claim, or mail notice of your claim to:
Warranty Claims
Alderon Industries, LLC
P.O. Box 827
Hawley, MN 56549
EXCLUSIVE REMEDY: In the event of a warranty claim that Alderon determines to be covered by this Limited Warranty, Al-
deron will, at its option, repair or replace the Product.
The above limited warranty and this exclusive remedy are the sole express warranty and remedy given by Alderon on the Prod-
uct. No warranties or representations at any time made by any representative from Alderon shall vary or expand the provisions
hereof. TO THE EXTENT PERMITTED BY LAW, ALL EXPRESS AND IMPLIED WARRANTIES (INCLUDING IMPLIED WAR-
RANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT) OTHER THAN
THE EXPRESS LIMITED WARRANTY SET FORTH ABOVE ARE EXPRESSLY DISCLAIMED. UPON THE EXPIRATION OF
THE ABOVE STATED LIMITED WARRANTY PERIOD, ANY AND ALL APPLICABLE IMPLIED WARRANTIES, INCLUDING,
WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-IN-
FRINGEMENT, ARE DISCLAIMED. SOME STATES DO NOT ALLOW LIMITATION ON HOW LONG AN IMPLIED WARRAN-
TY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY
FROM STATE TO STATE.
LIABILITY LIMITATION: In no event will Alderon’s liability to you or any other person or entity exceed the price paid to Alderon
for the defective Product. IN NO EVENT SHALL ALDERON BE LIABLE TO YOU OR ANY OTHER PERSON OR ENTITY
FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT OR SPECIAL DAMAGES OF ANY DESCRIPTION, WHETHER ARISING
OUT OF WARRANTY (INCLUDING ANY IMPLIED WARRANTIES) OR ANY OTHER CONTRACT, STRICT LIABILITY, NEG-
LIGENCE OR OTHER TORT, OR OTHERWISE, INCLUDING ARISING FROM INSPECTION OR REMEDY DELAYS. SOME
STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE
ABOVE LIMITATION AND EXCLUSION MAY NOT APPLY TO YOU.
Three-Year Limited Warranty - Standard Products
62800933.2

14 | Alderon Industries™ - Leading Edge Control Products
Mini Power Post™ - USER GUIDE
This page intentionally left blank

Alderon Industries™ - Leading Edge Control Products | 15
Mini Power Post™ - USER GUIDE
This page intentionally left blank

Company Location: 151 16th Street South, Hawley, MN 56549
Mailing Address: PO Box 827, Hawley, MN 56549
Main Ofce Phone: 218.483.3034
Website: alderonind.com
General Inquiry Email: [email protected]
Submit New Orders: orders@alderonind.com
UG00009_Rev06_PRPT-00003_Mini Power Post | May 27, 2022 11:31 AM
A
L
D
E
R
O
N
I
N
D
U
S
T
R
I
E
S
™
L
E
A
D
I
N
G
E
D
G
E
C
O
N
T
R
O
L
P
R
O
D
U
C
T
S
Other manuals for Mini Power Post PRPT-00003
1
Table of contents
Other Alderon Industries Control Unit manuals
Popular Control Unit manuals by other brands

System Sensor
System Sensor IM-10 Installation and maintenance instructions

MX
MX Options Concentric Fitting instructions

ThermOmegaTech
ThermOmegaTech GURU DL 2.1 installation instructions

Salda
Salda Stouch Technical manual

Seraphim
Seraphim SRP 6PB-DG installation guide

jbc
jbc NAE Series instruction manual