Alertgen SmartAlarm G5 User manual

Features Control Panel Layout
2
1
ARM + Auror CPU
Support 10 remote controls, 50 wireless sensors
and 50 RFID tags
Built-in 1,000,000 RF codes combination
maintains high reliability
Cellular communicator, simple operation
Store 5 phone numbers, 1 speed-dial number,
and 1 RFID SMS notification number
Exit and entry delay
SMS alert for low battery of two-way accessories
Arm and disarm the system by SMS or free phone call
Remote monitoring site via phone
Built-in loud speaker for siren and two-way talking
Built-in two pieces of 800mAh lithium batteries
enable 5-hour standby
SMS alerts for power failure, power recovery
and low battery
850/900/1800/1900MHz GSM frequency,
applicable for universal
Touch Keypad
Status Indicator
RFID Reader / Play Voice Memo
Call
Arm
Disarm
Stay Arm (Home Mode)
Record Voice Memo /
Connect Button
GSM Signal Indicator
GSM network searching: Flashes once every second
GSM signal in normal: Flashes once every two seconds
Alertgen G5 SmartAlarm

Bottom
4
3
Arm
Home mode
Disarm on keypad:
Disarm by RFID tag:
Press to arm the system.
Press to arm the sytem in home mode.
All the sensors in Normal Zone are armed except those in
Home Mode Zone which are disarmed so that user can move
freely at home.
Input 4 digits password (default:1234) , and press to disarm
the system after one beep.
If three beeps are heard, password is wrong and
please input again.
Induce the RFID tag to the RFID Reader area to
disarm the system.
MIC Tamper Switch Loudspeaker
Back-up Batteries

Record / Play Voice Memo
Press to record 10 seconds voice messages.
Or send SMS to system for calling back to record the
voice messages. The Play Voice Memo Button will be
flashing in green to remind you. Users can touch the
center of circle to listen to the voice memo. The LED
indicator blacks out when the voice memo is played.
Replay by touching it again.
6
5
Bottom
SIM Card Slot
Power On/Off
2 Inputs for
Wired Sensors
(24-hour zone)
Output for
Electronic Lock
Adapter Interface
Output for Wired Siren
≤ 500mA

8
7
Speed Dial
Phone Call
Electronic Lock Output
Press Call Button , the panel auto dials to pre-stored
phone number of the host, the LED blacks out after talk.
User can also press Call Button to end talk.
Dial phone number and then press Call Button to
start talk, the LED blacks out after talk.
User can also press Call Button to end talk.
When system is disarmed, the output signal opens
electronic lock automatically.
RFID Tag
The RFID tag is for disarming the system and unlocking
the electronic door lock (if connected).
You can rename the RFID tags and store a mobile phone
number to send SMS notice when family members come
home and disarm the system.
Note!
Only after SMS No. is stored, and the RFID tags SMS notice is
changed (4 RFID tags can be renamed), users can receive notice
SMS once someone disarms the system by RFID tag.
Nancy
Administrator
Mom
Nancy came home

10
9
???
SMS Operation
System replies third grade guide menu:
‘91~99’ Zone name
‘10’ RFID tags SMS notice
‘11’ Entry and exit delay time
‘12’ Siren volume and ringing time
‘13’ Disarm password
‘14’ Single zone delay time
Send:
??
‘5’ Store alarm phone No.
‘6’ Store alarm SMS No.
‘7’ Store SMS No. for RFID tags
‘8’ Store speed dial phone No.
‘???’ System setups
System replies second grade guide menu:
Send:
?
Insert a SIM card to the control panel,
then send a text of to the SIM card number,
the operation guide message will be replied.
You can control the alarm system by
following the guide message:
“?”
System replies first grade guide menu:
‘0’ Disarm
‘1’ Arm
‘2’ Home mode
‘3’ Two-way talk
‘4’ Call-back voice memo
‘00’ Settings inquiry
‘??’ Store phone and SMS No.
Send:

Arm
Stay Arm (Home Mode)
12
11
2
Send:
System in home mode.
1
Send:
System armed.
0
Disarm
Send:
System disarmed.

Settings Inquiry
14
13
00
System status
Entry and exit delay time: 0sec
Single zone delay time: 30sec
Siren volume: 2
Siren ringing time: 5min
Disarm password: 1234
Send:
Note:
Value of default setting will be changed
once users finish programming.
4
3
Two-Way Talk
Send to the SIM card number, the alarm will call back.
Pick up the phone and start two-way talk.
‘3’
Call-Back to Record Voice Memo
Send to the SIM card number, the alarm will call back.
Pick up the phone, and leave 10 seconds message.
The panel will hang up after 10 seconds.
‘4’
Send:
Send:

Store Alarm SMS No.
16
15
6
Send:
SMS:
1.
2.
3.
4.
5.
SMS:
1. 67890033
2. 67890022
3. 67890011
4. 67890000
5.
Forward > Edit
Store alarm SMS No.
successfully.
5
Send:
Store Alarm Phone No.
TEL:
1.
2.
3.
4.
5.
TEL:
1. 67890033
2. 67890022
3. 67890011
4. 67890000
5.
Forward > Edit
Store alarm phone No.
successfully.
Note:
Only after SMS No. is stored, and the
RFID tags SMS notice is changed, users
can receive notice SMS once someone
disarms the system by RFID tag.

Store Speed Dial Phone Number
18
17
8
Send:
Speed dial phone number
(0-20 digits):
1. 67890033
Forward > Edit
Store speed dial phone
number successfully.
Speed dial phone number
(0-20 digits):
1.
7
Store SMS No. for RFID tags
Send:
Forward > Edit
Store SMS No. for RFID
tags successfully.
SMS No. for RFID tags
(0-20 digits):
1.
SMS No. for RFID tags
(0-20 digits):
1. 67890033
Note: Only after SMS No. is stored, and the RFID tags
SMS notice is changed, users can receive notice SMS
once someone disarms the system by RFID tag.

91
Change Zone Name
Special Tips!
st th
Users can change the 1 ~ 9 zone names. The zone name should be 30
English characters at most for each line due to SMS character limit.
Other alarm zones are fixed as Zone 10 alarm, Zone 11 alarm and so on.
Send: 91~99
Zone1 name: Zone 1 alarm
Zone1 name: Entrance door sensor
Forward > Edit
SMS Alert for Low Battery of Accessories
(available for two-way accessories such as DWC-102 and PIR-910)
SMS will be sent for 1-9 zones with its zone name as
“Zone name + low battery”.
SMS alert for 10~50 zones will be “Zone number + low battery”.
(available for two-way accessories such as DWC-102 and PIR-910)
SMS will be sent for 1-9 zones with its zone name as
“Zone name + tamper alarm”.
SMS alert for 10~50 zones will be “Zone number + tamper alarm”.
20
19
Change zone name
successfully.
Bedroom PIR tamper
alarm.
Zone 10 tamper alarm.
Zone 10 low battery.
Bedroom PIR low battery.
SMS Alert for Tamper Alarm of Accessories

1110
Change RFID Tags SMS Notice Entry and Exit Delay Time
Send: Send:
Change RFID tags SMS
notice:
1.
2.
3.
4.
Change RFID tags SMS
notice:
1. Tom
2. Nurse
3. Nancy
4. David
Forward > Edit
Entry and exit delay time
(0-300 sec.):
0
Entry and exit delay time
(0-300 sec.):
10
Forward > Edit
Notice!
If users don’t want to take remote control or RFID cards with them,
this function can be used. Once the delay time is set, when you arm the system,
one beep will be heard every second to remind the user to leave.
The reminding rhythm will be speeded up in the last 15 seconds.
Once the intruder is detected, the alarm will be delayed accordingly.
22
21
Set delay time
successfully.
Change RFID tags SMS
notice successfully.
Note:
Only after SMS No. is stored, and the
RFID tags SMS notice is changed, users
can receive notice SMS once someone
disarms the system by RFID tag.

1312
Siren Volume and Ringing Time Disarm Password
Send: Send:
Siren volume(0 Mute,
1 Low, 2 High):
2
Siren ringing time(1-9min):
5
Forward > Edit
Disarm password(4-6 digits):
1234
Disarm password(4-6 digits):
8888
Forward > Edit
24
23
Set siren volume and
ringing time successfully.
Set disarm password
successfully.
Siren volume(0 Mute,
1 Low, 2 High):
1
Siren ringing time(1-9min):
3

0086
0001
14
Single Zone Delay Time Change System Language
Send: Send: 0086 to change language to be Chinese
Send: 0001 to change language to be English
Single zone delay time (0-300 sec.):
30
Single zone delay time (0-300 sec.):
15
Forward > Edit
26
25
Set single zone delay time
successfully.
Set English successfully.
中文语言修改成功!

21
22
0000
Delete Wireless Accessories by SMS Restore System to Default Setting by SMS
Send: Send:
Send:
Delete RFID Tags by SMS
Or press Tamper Switch 3 times within 3 seconds,
accessories will be cleared after two beeps.
Or press Tamper Switch 5 times within 3 seconds,
accessories will be cleared after two beeps.
28
27
Delete wireless accessories
successfully.
System has been restored
to factory settings.
Delete RFID tags
successfully.
Note:
After programming, only stored numbers can send SMS to
restore the system.

Arm & Disarm by Free Phone Call
Connect Wireless Accessories & RFID Tags
Arm
Disarm
Call the control panel number, hang up when hearing
the ring tone. The panel will call back. The user hangs
up the phone directly to arm the system.
Call the control panel number, hold on until the panel
hangs up the call.The panel will not call back. System
is disarmed.
Input 4-6 digits password, press Connect Button ,
the LED indicator lights up, then trigger the accessory
or RFID tag once within 15 seconds, the connection is
successful after a beep.
Once two beeps are heard, the accessory has been
connected before. The first connected accessory is in
Zone 1, the second one in Zone 2, and so on.
30
29
Connect Wireless Siren
The newly-added wireless siren can be used after
connecting to the control panel.
Press the Connect Button of the wireless siren for 0.5 second,
the Connect Button LED indicator lights on, and then press
the Arm Button on the control panel, the siren will be
connected after one beep is heard.
Testing: Press the Arm Button on the remote control, to make
sure that the internal siren and wireless siren both beep once,
the connection is successful. If not, the connection fails,
please reconnect them.
Once the intruder is detected, both internal siren and wireless
siren will hoot to deter the illegal intruder. (The siren will be
off in 5 minutes as the default setting). At the same time, the
alarm system will send SMS and auto dial to users.
Operation:

Radio frequency
Housing material
Operation condition:
Size (L x W x H) :
315MHz/433MHz (±75KHz)
ABS plastic
Temperature: -10ºC~55 ºC
Humidity: ≤ 80%(non-condensing)
Panel : 188×132×26mm
Specifications
GSM/SMS/RFID Security Alarm System
CG-G5
Input: AC 110-240V/50-60Hz
Output: DC 12V/500mA
850/900/1800/1900MHz
110mA
340mA
Lithium Battery : 3.7V/800mAh x 2 PCS (BL-5B)
90dB
10pcs remote controls, 50pcs wireless accessories,
and 50pcs RFID tags.
Product name :
Model No. :
Control panel’s power supply :
GSM working frequency :
Standby current :
Alarm current :
Internal battery backup :
Internal siren :
Allowed amount of expandable wireless accessories
32
31
Alertgen G5
SmartAlarm

Wireless Remote Control
LED Indicator
Disarm
Arm
Stay
Panic
Arm
Disarm
Home Mode
Press to arm the alarm panel and the LED indicator
lights on (siren hoots once), the system enters Arm state.
{Arm }
Press to disarm the alarm panel and the LED indicator
blacks out (siren hoots twice), the system is disarmed.
{Disarm }
When intruders are detected, siren will keep hooting. Press
to stop siren hooting.{Disarm }
Press button on the remote control, the system state
LED is on. All the sensors in Normal Zone are armed except the
motion detector in Home Mode Zone which is disarmed so that
user can move freely at home.
{Stay }
If there comes an intruder, the siren will hoot to deter the intruder.
(The siren turns off after ringing for 5 minutes as default setting.)
At the same time, the system dials the pre-stored phone numbers
automatically.
34
33

Mute Mode
Press button on the remote control, then press
or button, the siren keeps silent to finish
the operation. The system is armed or disarmed in mute without
disturbing other people.
{Stay }
{Arm } {Disarm }
Emergency Call
No matter what state the control panel is in, once SOS button on
the remote control is pressed, the system immediately goes into
emergent alarming state.
Zone Setup
Home Mode Zone Normal Zone
The PIR motion detector is set in Home Mode Zone in default.
It is recommended to set Door/Window Contact on entrance
in Single Delay Zone.
Users should reconnect the detector with the control panel after
the zone is changed.
Single Delay Zone
36
35
24-H Zone
Note: It is recommended to set smoke detector, gas
detector and outdoor beam sensor at 24-H zone.

Appearance
Wireless Door/Window Contact
Features
LED indicator
Transmitter Magnet
The DWC- 100 is a Door/Window Contact that can be
installed on doors, windows, and any other objects that open
and close. The sensor transmits signals to the control panel
when a mag net mou nted near the sensor is mov ed away.
External input for wired accessor y is available at the N/C
interface. The tampe r protection ensures that sabotage
attempts to move the contact will result in an alarm activation.
AA 1.5V LR6
LED Indication
Tamper switch
Zone setting
PCB Layout
LED flashes once:
LED lights on:
Door/window is opened and
transmitter sends signal to the control panel.
Low battery, please replace the
battery immed iately.
38
37

Installation & Notice
Ope n the case and remov e the battery activation strip.
Mou nt the sensor on the door frame and the mag net on the door.
Mak e sure the mag net is on the right side of the transmitter
Place the transmitter in the desired location, mou nt the
mag net no more than 1cm away from the transmitter and secure
the transmitter and magnet with double-sided tapes or screws.
Avoid mou nting sensors in areas with a large quantity of metal
or electrical wiring, such as a furnace or utility room.
Specifications
Power supply
Static current
Alarm current
Transmitting distance
Radio frequency
Housing mat erial
Operating temperature
Relative humidity
Transmitter dimen sions (LxWxH)
Magnet dimen sions (LxWxH)
DC 1.5V (AA 1.5V LR6 Battery x 1pc)
≤ 30uA
≤ 40mA
≤80m (in open area)
315MHz /433MHz (±75KHz)
ABS plastic
-10°C~55°C
≤80% (non-condensing)
71 x 34 x 17.5mm
51 x 12 x 13.5mm
40
39
Popular Security System manuals by other brands

GE Interlogix
GE Interlogix CONCORD Express installation instructions

Tiiwee
Tiiwee TWWA01 user manual

STI
STI SELECT-ALERT SA5000 Series instruction manual

AV-CAD
AV-CAD EasyLoader AV-2016D Installation and operation manual

Samsung
Samsung SSA-P102 user manual

Crystal Vision
Crystal Vision CVT9604E-3010W user manual