manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Alertgen
  6. •
  7. Security System
  8. •
  9. Alertgen SmartAlarm G5 User manual

Alertgen SmartAlarm G5 User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Features Control Panel Layout
2
1
ARM + Auror CPU
Support 10 remote controls, 50 wireless sensors
and 50 RFID tags
Built-in 1,000,000 RF codes combination
maintains high reliability
Cellular communicator, simple operation
Store 5 phone numbers, 1 speed-dial number,
and 1 RFID SMS notification number
Exit and entry delay
SMS alert for low battery of two-way accessories
Arm and disarm the system by SMS or free phone call
Remote monitoring site via phone
Built-in loud speaker for siren and two-way talking
Built-in two pieces of 800mAh lithium batteries
enable 5-hour standby
SMS alerts for power failure, power recovery
and low battery
850/900/1800/1900MHz GSM frequency,
applicable for universal
Touch Keypad
Status Indicator
RFID Reader / Play Voice Memo
Call
Arm
Disarm
Stay Arm (Home Mode)
Record Voice Memo /
Connect Button
GSM Signal Indicator
GSM network searching: Flashes once every second
GSM signal in normal: Flashes once every two seconds
Alertgen G5 SmartAlarm
Bottom
4
3
Arm
Home mode
Disarm on keypad:
Disarm by RFID tag:
Press to arm the system.
Press to arm the sytem in home mode.
All the sensors in Normal Zone are armed except those in
Home Mode Zone which are disarmed so that user can move
freely at home.
Input 4 digits password (default:1234) , and press to disarm
the system after one beep.
If three beeps are heard, password is wrong and
please input again.
Induce the RFID tag to the RFID Reader area to
disarm the system.
MIC Tamper Switch Loudspeaker
Back-up Batteries
Record / Play Voice Memo
Press to record 10 seconds voice messages.
Or send SMS to system for calling back to record the
voice messages. The Play Voice Memo Button will be
flashing in green to remind you. Users can touch the
center of circle to listen to the voice memo. The LED
indicator blacks out when the voice memo is played.
Replay by touching it again.
6
5
Bottom
SIM Card Slot
Power On/Off
2 Inputs for
Wired Sensors
(24-hour zone)
Output for
Electronic Lock
Adapter Interface
Output for Wired Siren
≤ 500mA
8
7
Speed Dial
Phone Call
Electronic Lock Output
Press Call Button , the panel auto dials to pre-stored
phone number of the host, the LED blacks out after talk.
User can also press Call Button to end talk.
Dial phone number and then press Call Button to
start talk, the LED blacks out after talk.
User can also press Call Button to end talk.
When system is disarmed, the output signal opens
electronic lock automatically.
RFID Tag
The RFID tag is for disarming the system and unlocking
the electronic door lock (if connected).
You can rename the RFID tags and store a mobile phone
number to send SMS notice when family members come
home and disarm the system.
Note!
Only after SMS No. is stored, and the RFID tags SMS notice is
changed (4 RFID tags can be renamed), users can receive notice
SMS once someone disarms the system by RFID tag.
Nancy
Administrator
Mom
Nancy came home
10
9
???
SMS Operation
System replies third grade guide menu:
‘91~99’ Zone name
‘10’ RFID tags SMS notice
‘11’ Entry and exit delay time
‘12’ Siren volume and ringing time
‘13’ Disarm password
‘14’ Single zone delay time
Send:
??
‘5’ Store alarm phone No.
‘6’ Store alarm SMS No.
‘7’ Store SMS No. for RFID tags
‘8’ Store speed dial phone No.
‘???’ System setups
System replies second grade guide menu:
Send:
?
Insert a SIM card to the control panel,
then send a text of to the SIM card number,
the operation guide message will be replied.
You can control the alarm system by
following the guide message:
“?”
System replies first grade guide menu:
‘0’ Disarm
‘1’ Arm
‘2’ Home mode
‘3’ Two-way talk
‘4’ Call-back voice memo
‘00’ Settings inquiry
‘??’ Store phone and SMS No.
Send:
Arm
Stay Arm (Home Mode)
12
11
2
Send:
System in home mode.
1
Send:
System armed.
0
Disarm
Send:
System disarmed.
Settings Inquiry
14
13
00
System status
Entry and exit delay time: 0sec
Single zone delay time: 30sec
Siren volume: 2
Siren ringing time: 5min
Disarm password: 1234
Send:
Note:
Value of default setting will be changed
once users finish programming.
4
3
Two-Way Talk
Send to the SIM card number, the alarm will call back.
Pick up the phone and start two-way talk.
‘3’
Call-Back to Record Voice Memo
Send to the SIM card number, the alarm will call back.
Pick up the phone, and leave 10 seconds message.
The panel will hang up after 10 seconds.
‘4’
Send:
Send:
Store Alarm SMS No.
16
15
6
Send:
SMS:
1.
2.
3.
4.
5.
SMS:
1. 67890033
2. 67890022
3. 67890011
4. 67890000
5.
Forward > Edit
Store alarm SMS No.
successfully.
5
Send:
Store Alarm Phone No.
TEL:
1.
2.
3.
4.
5.
TEL:
1. 67890033
2. 67890022
3. 67890011
4. 67890000
5.
Forward > Edit
Store alarm phone No.
successfully.
Note:
Only after SMS No. is stored, and the
RFID tags SMS notice is changed, users
can receive notice SMS once someone
disarms the system by RFID tag.
Store Speed Dial Phone Number
18
17
8
Send:
Speed dial phone number
(0-20 digits):
1. 67890033
Forward > Edit
Store speed dial phone
number successfully.
Speed dial phone number
(0-20 digits):
1.
7
Store SMS No. for RFID tags
Send:
Forward > Edit
Store SMS No. for RFID
tags successfully.
SMS No. for RFID tags
(0-20 digits):
1.
SMS No. for RFID tags
(0-20 digits):
1. 67890033
Note: Only after SMS No. is stored, and the RFID tags
SMS notice is changed, users can receive notice SMS
once someone disarms the system by RFID tag.
91
Change Zone Name
Special Tips!
st th
Users can change the 1 ~ 9 zone names. The zone name should be 30
English characters at most for each line due to SMS character limit.
Other alarm zones are fixed as Zone 10 alarm, Zone 11 alarm and so on.
Send: 91~99
Zone1 name: Zone 1 alarm
Zone1 name: Entrance door sensor
Forward > Edit
SMS Alert for Low Battery of Accessories
(available for two-way accessories such as DWC-102 and PIR-910)
SMS will be sent for 1-9 zones with its zone name as
“Zone name + low battery”.
SMS alert for 10~50 zones will be “Zone number + low battery”.
(available for two-way accessories such as DWC-102 and PIR-910)
SMS will be sent for 1-9 zones with its zone name as
“Zone name + tamper alarm”.
SMS alert for 10~50 zones will be “Zone number + tamper alarm”.
20
19
Change zone name
successfully.
Bedroom PIR tamper
alarm.
Zone 10 tamper alarm.
Zone 10 low battery.
Bedroom PIR low battery.
SMS Alert for Tamper Alarm of Accessories