17
Setting the time
You can set the operation of the time and it can be seen on the lower red indicator of the keyboard. When you’re
programing the operation of the time, it functions also when the stove is not switched on since it is charged by a
battery.
You must adjust the time if you want to program the stove operation, that is, if you want to program automatic
switching on and switching off of the stove.
The procedure for adjustment of the time is the following:
Press the button 3 twice until the flickering message UT01 appears.
At that moment, press the buttons 1 and 2 to adjust the day in the week (day 1 corresponds to Monday, continuing
further to day 7 which corresponds to Sunday). Adjust the day when you make the adjustment of the time (for example,
if it is Monday, set DAY1).
Than press the button SET once you set the day. The display shown a flickering message UT02. Now here you can
set the time by using the buttons 1 and 2. After you press the button SET one more time (to confirm the inserted time),
the flickering message UT03 appears and now you can change the minutes of the time again by using the buttons 1
and 2.
After setting the minutes, press the button SET once again to get the message UT04 which corresponds to the
programing of the technical parameters (use only authorized repairmen).
Once you have adjusted and confirmed the operation of the clock, the LED lamp 1 (left, up) on the keyboard will switch
on and will stay on. Temporarily recontrol the accuracy of the clock and if it is disrupted you can adjust it once again
according to the manner described above.
In order to come out of the program at any time, press once the button for switching off the stove (button 4) in
duration of not less than 2 seconds.
Automatic starting and switching off of the stove
If you want automatic starting and switching off of the stove, the clock must be adjusted as described.
Once you’ve adjusted the clock and reached the parameter UT04, press SET once again to go to UT05. Now here you
can select the time of starting for the program of the first automatic starting of the stove, again by using the buttons 1
and 2.
We would like to remind you that the stove starting and switching off can be programmed four times in one day, seven
days in the week. The first cycle of starting/switching off takes place though the program 1, with presented parameters
UT05, UT06 and UT07. Another cycle of starting/switching off take place through the program 2 and it can be modified
through the parameters UT08, UT09 and UT10. The third program is performed with the parameters UT11, UT12,
UT13 and the fourth program is performed through the parameters UT14, UT15 and UT16.)
Once you adjust the starting time for the first program, use the button SET to move to parameter UT06, where you can
adjust the switching off time of the stove, again by using the buttons 1 and 2.
Once you confirm the selected switching off time by using the button SET, then you go to parameter UT07, where you
determine, that is, you set the days in the week when the previously defined program of starting / switching off will be
active, that is, when it will act.
Then the message "ON1" appears. This means than on day 1 (previously defined with the parameter UT01) the first
program of starting/switching off will be active i.e. it will act at that moment. In order to switch off the automatic starting,
switching off of the stove on that day, now press the button 2 and the display will show the message OFF1 (switched
off programming for that day).
If instead of that you press the button 1, go to day 2 ("ON2") where in the same manner you can activate or switch off
the first starting program with button 2.
Continue in the same manner to activate/deactivate the programs for the remaining days in the week.
After programing the starting/switching off of the stove operation for different days in the week, once again press the
button SET in order to get access according to the sequence of parameters UT08, UT09 and UT10, which represent
the parameters for adjusting another program for starting/switching off the stove, which can be memorized.
In order to turn off, that is, to delete all weekly and daily programs for starting and switching off of the stove
for program 2 (when there is no more flickering of the UT parameter), press the button SET until UT10 appears
on the display, than select OFF from the given selection by pressing the buttons 1 or 2 for all 7 days,
separately for each day.
If you want to turn off, that is, to delete the programmed starting and switching off of the stove of the program
1, you should press SET to get to UT07, for program 3 to get to UT13, for program 4 to get to UT16 and in the
described manner as for program 2 (UT10) cancel all programs for starting and switching off of the stove for
all days (everywhere it should be OFF-switched off).
9.4 ALARM MANAGEMENT
An alarm signal (meaning that the stove informs about the occurrence of a certain problem with a sound signal)
appears in the following cases:
ORIGIN OF THE ALARM INDICATION ON THE DISPLAY
Probe for smoke temperature ALARM SOND FUMI
Probe for smoke temperature ALARM HOT TEMP
Failed ignition ALARM ACC NO
Stoppage of stove operation ALARM NO FIRE
Lack of power supply ALARM NO RETE
Safety pressure switch of the snail (spiral) ALARM DEP NO