The RS200/300 Electric Strike is surface mounted and designed with the strength and durability for use with rim
exit devices with a 1/2” (RS200) or 3/4” (RS300) throw Pullman latchbolt. No cutting on the frame is required for
installation. Unit is field selectable for fail-safe and fail-secure operation, and for 12 or 24VDC. The RS200 has
a 1/2” (12.7mm) thick metal housing. The RS300 has a 3/4” (19mm) thick metal housing.
RS200/300 Electric Strike Installation Instructions
Overheated or burnt coils caused by incorrect voltage/wire
harness combinations will not be covered under warranty
CAUTION
Dynamic Strength
Endurance Rating
70 ft-lbs
1500 lbs
14°F to 120°F(-10°C~+49°C)
250,000 cycles
Field selectable fail-safe and
fail-secure Non-fire rated model
• The RS200/300 series is intended to be used with UL Listed Exit
hardware
• The RS200/300 series shall not impair the intended operation of
an emergency exit
• The RS200/300 series shall not impair the operation of panic
hardware mounted on the door
(On select models)
UL Requirements
WARNING
Warnings indicate potentially hazardous
conditions, which if not avoided or corrected,
may cause death or serious injury.
CAUTION
Cautions indicate potentially hazardous
conditions, which if not avoided or corrected,
may cause minor or moderate injury. Cautions
may also warn against unsafe practices.
NOTICE
Notices indicate a condition that may cause
equipment or property damage only.
Black
12 VDC
Dual Voltage
Red
White
Green
(Polarity Free)
White
24 VDC
24 VDC
Green
Black
Red
(Polarity Free)
Destructive Attack: Level I
Line Security: Level I
Standby Power: Level I
Endurance: Level IV
UL294
Performance Level