pag. 1 / 2 6-1625231 rev.00 02/02/2021
BIOS2 230
QUICK START GUIDEQUICK START GUIDE
product code 12006515product code 12006515
FAQs
One or more safety Leds (EDGE, PH2, PH1, STOP) are switched o.
Check accessories fuse and connection to the device related to the LED that is
turned o. Every safety device, if present, must be connected to the card with a
contact NORMALLY CLOSED and the corresponding DIP SWITCH must be in OFF.
During the learning of the strokes the gate does not move.
Check fuses, check motors connection and capacitors to the control unit.
During the learning of the strokes the gate moves but very slowly and
fatigue.
Check motors installation dimensions and maximum weight supported by the
motors. Check that, with the motors unlocked, the gate moves by hand smoothly
and with no dicult for the entire length of the stroke. Set the basic SSL para-
meter to 1.
During the learning of the strokes the gate doors moves simultaneously
or with an incorrect sequence.
Verify correct connection of motors phases (L1 – L2 – COM) to the control unit
and that there are no short circuits between them.
TECHNICAL CHARACTERISTICS
Power Supply (board) 230Vac - 50/60Hz
Absorption (board) 55mA @ 230Vac
Motors power supply 230Vac - 50/60Hz
Max power absorbed from motors 2 x 700W
Radio receiver 433MHz - Rolling Code Allmatic
Max transmitters 1000
3
4
5
M1
L1 phase
L2 phase
COMMON
6
7
8
M2
L1 phase
L2 phase
COMMON
1
2
L
N230Vac 50Hz
UP DOWN
MENU
SS
> 2”
< 1”
UP DOWN
MENU
SS > 2”
UP DOWN
MENU
SS
UP DOWN
MENU
SS > 2”
M1 M2
M1
32026 Borgo Valbelluna - Belluno – Italy
Via dell’Artigiano, n°1 – Z.A.
Tel. 0437 751175 – 751163 r.a. Fax 0437 751065
CONNECTION DIAGRAM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
30 31
TRASF
FUSE FUSE
FUSE
BLUETOOTH
SLOT MODULE
RADIO
MODULE
R1 SLOT
MODULE
R. MEMORY
MODULE
SECURITY
DIP-SWITCH
LINE FUSE
F 6.3A
ACCESSORIES Vdc
FUSE F 0.5A
ACCESSORIES Vac
FUSE F 2.0A
24Vac 9W
OUTPUT
230Vac 50Hz
NL
M1
L1 L2
COM
M2
L1 L2
COM
COURTESY
LIGHT OUTPUT
230Vac 100W MAX
FLASHING LAMP
with FIX LIGHT
230Vac 60W MAX
COM
PHOTOCELLS
N.C. CONTACT
RX TX
PHOTOCELLS
SUPPLY OUTPUT
24Vdc 5W MAX
ELECTRIC LOCK
12Vac 15W MAX
+24Vdc
GND
+24Vdc TX
TEST PHOTO
KEY SELECTOR
N.O. CONTACTS
STEP-BY-STEP
AND PARTIAL OPEN
STOP BUTTON
N.C. CONTACT
1 2
19
18
GND
+ -
+24Vdc TX
17
18
1 2 3 4 5
GND
+-
+24Vdc RX
COM
N.C.
23
29
common
N.C. contact
1 2 3 4 5
1 2 1 2 3 4 5
1 2
LED ON
LED OFF
POWER SUPPLY and MOTOR SETTINGS
CONNECTING ONE PAIR of IRIS PHOTOCELL
15
16
MAX 12Vac 15W
1
2
RELE
R1
UP DOWN
MENU
SS
> 5”
< 1”
UP DOWN
MENU
SS > 2”
UP DOWN
MENU
SS
UP DOWN
MENU
SS > 2”
CONNECTING the ELECTRIC LOCK
OR
TYPE A
CONNECTION
TYPE B
CONNECTION
11
12
MAX 230Vac 60W
UP DOWN
MENU
SS
> 5”
< 1”
UP DOWN
MENU
SS > 2”
UP DOWN
MENU
SS
UP DOWN
MENU
SS > 2”
CONNECTING the FLASHING LAMP
TX
photocell
RX
photocell TX TXRX RX
Beam
status
Control Unit
Led status
DIP PH1
set to OFF
DON’T USE lamp with
auto-flashing circuit
< 1”
UP DOWN
MENU
SS
< 1” < 1”
LEARNING of one TRANSMITTER
STEP-BY-STEP
function
associated
10” TIMEOUT
1
2
3
4
On the same transmitter you can learn the following functions (IN SEQUENCE):
STEP-BY-STEP
function
1st CLOSE
function
4th
PARTIAL OPEN
function
2nd OPEN
function
3rd
The address number associated
is displayed. (e.g. “255”)
LED
OFF
LED
ON
ENG
External
power supply
1 2 3 4 5 6
1 2 3 4 5
1 2 3 4 5
1 2 3 4
1 2 3 4
5
1
2
3
4
5