ALLTEC ExoTHERM User manual

Suitable For Use With All HWE Machines
Powerful Twin Element 2.4kW Heaters
2 Power Levels: 1.2kW & 2.4kW
Adjustable Temperature 0-90°C
Low & High Pressure Safety Cut Out
5m/16ft Power Cable
Fully Serviceable
THE NEW ALLTEC HEAT & RUN BOX
All manuals and user guides at all-guides.com
TheAlltec Heat & Run Box
ExoTHERM
OPERATION
INSTRUCTIONS
Set
up
your
hot
water
extraction
(
HWE
)
machine
ready
for
use.
Connect
the
ExoTHERM
either
directly
to
your
machine
with
the
hose
supplied,
or
to
the
end
of
an
extension
hose.
Connect
a
hose
to
the
ExoTHERM
solution
outlet
ready
for
use.
Connect
the
ExoTherm
to
a
power
outlet.
(
Extension
leads
are
not
recommended,
but
if
absolutely
necessary
ensure
single
socket,
heavy
duty
extension
lead
is
used.
)
Turn
on
the
mains
power.
Select
low
or
high
heat
and
set
required
temperature.
Turn
on
your
HWE
machine
and
set
your
pressure
-
for
use
with
the
ExoTherm
this
should
be
between
100
-
400psi.
Allow
the
ExoTHERM
to
warm
up
for
60
seconds
before
use.
Start
cleaning
and
the
water
will
come
through
hot
within
a
few
moments.
Just
before
finishing
cleaning,
turn
off
the
ExoTHERM
and
continue
cleaning
to
help
reduce
the
unit
'
s
temperature
to
make
it
more
comfortable
to
pack
away.
All manuals and user guides at all-guides.com
IMPORTANT
NOTE
-
Action
required
on
first
use:
Connect
the
heater
as
described
but
before
connecting
the
power
turn
on
your
water
pump
and
pull
the
wand
/
tool
trigger
until
water
runs
freely
without
any
air
splutter.
Thereafter
this
procedure
is
not
required
unless
the
unit
has
sat
empty
or
unused
for
a
length
of
time.
Warnings:
Do
not
allow
the
unit
to
freeze,
this
can
damage
components
which
can
be
costly
to
replace
/
repair.
Optimum
water
input
temperature
is
40
°
C,
high
temperatures
may
not
allow
the
thermostat
to
operate
as
effectively
causing
cooler
periods
in
operation.
If
warning
LED
'
s
are
lit
the
unit
will
not
operate,
check
for
too
low
or
high
pressure.
Safety
Features:
Low
pressure:
the
unit
will
not
operate
without
a
machine
&
water
pump
connected
and
turned
on.
High
pressure:
the
unit
will
not
operate
over
500psi.
(
The
unit
has
been
pressure
tested
to
1200psi
however
it
is
designed
to
cut
out
at
500psi
for
safety
reasons.
)
Unit
will
not
over
-
pressurise
if
left
turned
on
without
being
used.
All
components
in
this
unit
are
completely
serviceable,
we
recommend
the
unit
is
returned
to
Alltec
for
regular
servicing
and
electrical
testing.
All manuals and user guides at all-guides.com
Alltec Network Ltd
Butts Business Centre
Fowlmere, Royston
Hertfordshire
SG8 7SL
01763 208222
info@alltec.co.uk
www.alltec.co.uk
All manuals and user guides at all-guides.com

Popular Heating System manuals by other brands

frenzelit hicoTHERM 60 Installation and operating instructions

frenzelit

frenzelit hicoTHERM 60 Installation and operating instructions

Daikin VRV IV+ Service manual

Daikin

Daikin VRV IV+ Service manual

Benchmark Gledhill BoilerMate 2000 125 Design, installation and servicing instructions

Benchmark

Benchmark Gledhill BoilerMate 2000 125 Design, installation and servicing instructions

jbc PHSK PHSE-1KB instruction manual

jbc

jbc PHSK PHSE-1KB instruction manual

Viessmann VITOVENT 300 installation instructions

Viessmann

Viessmann VITOVENT 300 installation instructions

SND SND-1500-3 owner's manual

SND

SND SND-1500-3 owner's manual

COBRILLO Hydraulic radiators Instruction and use manual

COBRILLO

COBRILLO Hydraulic radiators Instruction and use manual

Ferroli UT REC micro E H Series Installation, use and maintenance manual

Ferroli

Ferroli UT REC micro E H Series Installation, use and maintenance manual

Salda RIS 400HW 3.0 Technical data

Salda

Salda RIS 400HW 3.0 Technical data

Baxi Assure Vertical SHRU Installation & maintenance manual

Baxi

Baxi Assure Vertical SHRU Installation & maintenance manual

oventrop Flypass 4TZ Installation and operating instructions

oventrop

oventrop Flypass 4TZ Installation and operating instructions

Spirax Sarco SpiraHeat Installation and maintenance instructions

Spirax Sarco

Spirax Sarco SpiraHeat Installation and maintenance instructions

Burlington Trafalgar R1 CHR installation instructions

Burlington

Burlington Trafalgar R1 CHR installation instructions

Roberts Gorden CoRayVac B-2 instructions

Roberts Gorden

Roberts Gorden CoRayVac B-2 instructions

BrookVent aircycle ONE 100 Installation, maintenance & user manual

BrookVent

BrookVent aircycle ONE 100 Installation, maintenance & user manual

Envirovent energiSava 500 Installation guide for engineer / installer

Envirovent

Envirovent energiSava 500 Installation guide for engineer / installer

DEVI DEVIcomfort 10T installation guide

DEVI

DEVI DEVIcomfort 10T installation guide

Monoflo Heat mats Instruction

Monoflo

Monoflo Heat mats Instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.