Alltrax FN2 for XCT Controllers
With the “SPEED” and “Throttle Rate” tied to ether in software, you can adjust both sliders for “mild to wild” so
when the Speed or Re en pot are full left minimum, the throttle rate AND the speed are soft and slow and the
Re en is soft and will coast. When the knobs are at full ri ht (Clock wise) is fast and wild. You can tune these two
parameters for drivin style. With the knob to full left, you save power and reduce battery draw, at full ri ht (in
this example) its full power performance mode as shown below.
In this example, the speed limit RPM is spread across 2450 to 6087RPM (depends on the motor RPM limits) and
Re en is set for a soft 80 amps up to a crawlin down a steep rade 300amps.
The software also has a feature to “Hi hli ht the knob” when you hover over the slider bar down below. This helps
identify which slider you’re affectin . In this example the mouse (red arrow) is hoverin over the REGEN slider
makin the re en knob hi hli hted.