manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. alocity
  6. •
  7. Control Unit
  8. •
  9. alocity F3D100 User manual

alocity F3D100 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

F3D100 All-in-one Access Control Device
FCC ID: P27F3D100
Installation to be performed only by certiÞed installer!
Power Sourcing Requirement: PoE+ (802.3at Type 2) 30W!
Unit to be powered by UL294B certiÞed IEEE PoE+ 802.3at Type 2 Power Sourcing
Equipment using unshielded cat5e or better cable with a maximum cable length of
330 feet (100 meters)!
A ULC 60839-11-1 Listed power supply with appropriate grade is required to be
provided for ULC installations!
Wiegand/OSDP Badge Reader max cable length: 5 ft - 22 AWG (1.5 m)!
Wiegand Panel max cable length: 500 ft - 22 AWG (152 m), 300 ft - 24 AWG (91 m)
OSDP Panel max cable length: 4000 ft - 24 AWG (1,219 m),
Installation Prerequisite
Connect Directly to an Electric Lock
Fail Safe Lock
There is normally a current ßowing through the relay on the Fail Safe lock. When the relay is
activated, the current ßown is blocked, and the door lock will open. If the power supply is cut o"
due to a power failure or an external factor, the door will remain open.
NC -Burgundy/Yellow
COM - Brown/Red
-!
+
Connect the two NC wires together to the + wire
on the lock. !
Connect the two COM (Brown/Red) wires to the
+ wire on the power source.!
Connect the - negative wire from the power
source to the - negative on the lock.!
Each wire supports up to 1A, connecting
together will allow for up to 2A current to ßow.
F3D100 Pigtail
Fail Secure Lock
There is no current ßowing through the relay on the Fail Secure lock. When the relay is activated, the
current ßow is opened, and the door lock will open. If the power supply is cut o"due to a power
failure or an external factor, the door will remain closed.
NO - Orange/Red
COM - Brown/Red
-!
+
Connect the two NO wires together to the + wire
on the lock. !
Connect the two COM (Brown/Red) wires to the
+ on the power source.!
Connect the - wire from the power source to the
- on the lock.!
Each wire supports up to 1A, connecting
together will allow for up to 2A current to ßow.
F3D100 Pigtail
Connect Power over Ethernet Cable (PoE)
The F3D100 uses 802.3at (PoE+).!
Connect a Cat5/6 ethernet cable to the RJ45 located on the pigtail of the F3D100.!
To setup network connection use the Alocity setup app.!
Wiegand
Output Wiegand 0 Green / Black
Output Wiegand 1 Orange / Balck
Input Wiegand 0 Burgundy / Blue
Input Wiegand 1 Brown / White
Ground Black
OSDP / RS485
RS485 A Orange /White
RS485B Green / White
Ground Black
Inputs
Input 1 Green / Yellow
Input 2 White
Ground Brown / Yellow
Wiegand Input/Output Wiring Diagram
OSDP Wiring Diagram
Input for Exit button & Door Contact Sensor
Wiring Diagram
Max number of face/templates enrolled shall not exceed 10,000!
Ethernet/PoE+ and Wiegand Cable to Reader and Panel are Class II/Power Limited !
Equipment not intended for connection to telephone, or outside wiring as covered by Article 800 in the
National Electrical Code, NFPA 70!
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.!
CAUTION: Any changes or modiÞcations to this device not explicitly approved by the manufacturer could
void your authority to operate this equipment.!
ATTENTION: Tout changement ou toute modiÞcation apportés à cet appareil sans l’approbation expresse
du fabricant risque d’invalider l’autorisation relative à son utilisation.!
CE Marking
Alcatraz AI hereby declares that these facial authentication devices are in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.