manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Altos
  6. •
  7. Server
  8. •
  9. Altos BrainSphere R385 F4 User manual

Altos BrainSphere R385 F4 User manual

Other Altos Server manuals

Altos BrainSphere R385 F5 User manual

Altos

Altos BrainSphere R385 F5 User manual

Altos R360 F5 SFF User manual

Altos

Altos R360 F5 SFF User manual

Altos BrainSphere R680 F4 User manual

Altos

Altos BrainSphere R680 F4 User manual

Altos BrainSphere R365 F4 User manual

Altos

Altos BrainSphere R365 F4 User manual

Altos BrainSphere R369 F4 User manual

Altos

Altos BrainSphere R369 F4 User manual

Altos BrainSphere T350 F4 User manual

Altos

Altos BrainSphere T350 F4 User manual

Altos BrainSphere R185 F5 User manual

Altos

Altos BrainSphere R185 F5 User manual

Altos Altos BrainSphere R365 F5 User manual

Altos

Altos Altos BrainSphere R365 F5 User manual

Altos BrainSphere P530 F4 User manual

Altos

Altos BrainSphere P530 F4 User manual

Altos R320 F5 User manual

Altos

Altos R320 F5 User manual

Altos BrainSphere T310 F5 User manual

Altos

Altos BrainSphere T310 F5 User manual

Altos R380 F5 User manual

Altos

Altos R380 F5 User manual

Altos BrainSphere R580 F4 User manual

Altos

Altos BrainSphere R580 F4 User manual

Altos T110 F5 User manual

Altos

Altos T110 F5 User manual

Altos BrainSphere R685 F5 User manual

Altos

Altos BrainSphere R685 F5 User manual

Popular Server manuals by other brands

HP Tc2120 - Server - 256 MB RAM installation guide

HP

HP Tc2120 - Server - 256 MB RAM installation guide

Lenovo ThinkServer RD230 manual

Lenovo

Lenovo ThinkServer RD230 manual

Avocent CPS810 Installer/user guide

Avocent

Avocent CPS810 Installer/user guide

Dell PowerEdge R6615 Installation and service manual

Dell

Dell PowerEdge R6615 Installation and service manual

FreeWave HT2+ installation guide

FreeWave

FreeWave HT2+ installation guide

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

GIGA-BYTE TECHNOLOGY

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

Lanner HTCA-E400 user manual

Lanner

Lanner HTCA-E400 user manual

Bull NovaScale T840 E2 user guide

Bull

Bull NovaScale T840 E2 user guide

Asus RS740-E70RS24-EG Configuration guide

Asus

Asus RS740-E70RS24-EG Configuration guide

Meinberg LANTIME M300/TCR manual 

Meinberg

Meinberg LANTIME M300/TCR manual 

HP ProLiant SL335s G7 Maintenance and service guide

HP

HP ProLiant SL335s G7 Maintenance and service guide

ZyXEL Communications VANTAGE RADIUS 50 user guide

ZyXEL Communications

ZyXEL Communications VANTAGE RADIUS 50 user guide

Lantronix xDirect-IAP quick start guide

Lantronix

Lantronix xDirect-IAP quick start guide

Fujitsu PRIMEQUEST 2400E3 General description

Fujitsu

Fujitsu PRIMEQUEST 2400E3 General description

IBM 9040-MR9 manual

IBM

IBM 9040-MR9 manual

IBM 306m - eServer xSeries - 8849 user guide

IBM

IBM 306m - eServer xSeries - 8849 user guide

green hippo Hippotizer Nevis+ quick start guide

green hippo

green hippo Hippotizer Nevis+ quick start guide

IBM 8203-E4A Brochure & specs

IBM

IBM 8203-E4A Brochure & specs

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

使用手冊
BrainSphere
R385 F4
系統設定
系統注意事項
感謝您購買 Altos 伺服器。 本使用手冊專供專業的伺服器技術人員參考用,並詳細說明
Altos 伺服器所擁有的眾多功能。 如需任何特定元件或軟體解決方案的詳細資訊,請參閱
該應用程式的技術規格或使用手冊。
注意:在打開或取出任何元件之前,請先聯絡
當地經過認證的 Altos 客服人員。
警告! 未經認證的技術人員在更換元件期間
造成的任何零件或元件毀損,將不在保固涵蓋
範圍內。 如需詳細資訊,請參閱系統內的
保固手冊。
功能模組介紹
Altos BrainSphere R385 F4 系統配置前視圖:
24x 2.5” Drive SKU
No.
Description
1. Front Panel LEDs and buttons
2. HDD Bays
3. Front USB 3.0 ports
12x 3.5” Drive SKU
No.
Description
1. Front Panel LEDs and buttons
2. HDD Bays
3. Front USB 3.0 ports
2
1
3
HDD #0 HDD #3
HDD #9
HDD #11
1
2
3
HDD #1
HDD #2
HDD #4
HDD #5
HDD #6
HDD #7
HDD #8
HDD #10
Altos BrainSphere R385 F4 後視圖:
No.
Description
1. VGA port
2. USB 3.0 ports
3. LAN ports
4. COM port (RJ45 type)
5. 10/100/1000 Server management LAN port
Rear HDD #0
Rear HDD #1
Secondary Primary PSU
1
2 3 4 5
系統控制和指示燈
前面板控制
No. Name
Color
Status
Description
1. Reset Button
--
--
Press this button to reset the system.
Press this button for the server to generate a NMI to the
2. NMI button
--
--
processor. If multiple-bit ECC errors occur, the server will
effectively be halted.
Power button
3.
with LED
Green
On Indicates the system is powered on.
Green
Blink
System is in ACPI S1 state (sleep mode).
•System is not powered on or in ACPI S5 state (power off)
N/A
Off
•System is in ACPI S4 state (hibernate mode)
4. ID Button
with LED
Blue
On
Indicates the system identification is active.
N/A
Off
Indicates the system identification is disabled.
5. HDD Status
LED
Green
On Indicates locating the HDD.
Blink
Indicates accessing the HDD.
Amber
On Indicates HDD error.
Green/
Amber
Blink
Indicates HDD rebuilding.
N/A
Off
Indicates no HDD access or no HDD error.
6. System
Status LED
Green
On Indicates system is operating normally.
Amber
Indicates a critical condition, may include:
On -System fan failure
-System temperature
Indicates non-critical condition, may include:
Blink
-Redundant power module failure
-Temperature and voltage issue
N/A
Indicates system is not ready, may include:
Off -POST error
-NMI error
-Processor or terminator is missing
7. LAN1 Active/
Link LED
Green
On Indicates a link between the system and the network or
no access.
Green
Blink
Indicates data trasmission or receiving is occuring.
N/A
Off
Indicates no data transmission or receiving is occuring.
8. LAN2 Active/
Link LED
Green
On Indicates a link between the system and the network or
no access.
Green
Blink
Indicates data trasmission or receiving is occuring.
N/A
Off
Indicates no data transmission or receiving is occuring.
1 2
3 4
5 6
7
後面板控制
No.
Name
Color
Status
Description
1. 1GbE
Speed LED
Yellow On 1 Gbps data rate
Green On 100 Mbps data rate
N/A Off 10 Mbps data rate
1GbE
2. Link/
Activity
LED
Green
On Link between system and
network or no access
Blink
Data transmission or receiving is occurring
N/A
Off No data transmission or
receiving is occurring
硬碟插槽 LED 指示燈
2.5” Drive SKU
3.5” Drive SKU
RAID SKU
LED1
Locate
HDD
Fault
Rebuilding
HDD
Access
HDD Present
(No Access)
No RAID configuration
(via HBA, ICH)
Disk LED
(LED on
Back Panel)
Green
ON(*1)
OFF
Green
OFF
Amber
OFF
OFF
Amber
OFF
Removed HDD Slot
(LED on Back Panel)
Green
ON(*1)
OFF
Green
--
Amber
OFF
OFF
Amber
--
RAID configuration
(via HW RAID Card or
SW RAID Card)
Disk LED
Green
ON
OFF
Alternately
OFF
Amber
OFF
ON
(Low Speed: 2 Hz)
OFF
Removed HDD Slot
Green
ON(*1)
OFF
(*3)
--
Amber
OFF
ON
(*3)
--
LED 2
HDD Present
No HDD
Green
ON
OFF
NOTE:
*1: Depends on HBA/Utility Spec.
*2: Blink cycle depends on HDD's activity signal.
*3: If HDD is pulled out during rebuilding, the disk status of this HDD is regarded as faulty.
1 2 1 2
1 2
LED#1
LED#2(Reserved/No Function)
LED#1
LED#2(Reserved/No Function)
電線供應器模組 LED 指示燈
PSU LED
State
Description
Green ON
Output ON and OK
Off
No AC power to all power supplies
Green BLINKING
1 Sec./On
1 Sec./Off
0.5Hz
Standby Mode (normal)
Green BLINKING
0.25 Sec./On
0.25 Sec./Off
2Hz
PSU Sleep Mode (cold Redundant/Offline mode)
Standby Mode (with OTP range)
Amber
12V Fault (OVP, UVP, OCP, SCP, and OTP)
Power Supply fan lock (15 seconds
including Standby mode)
Amber
(*3)
設定系統
安裝前需求
選擇擺置地點
在拆開和安裝系統之前,請先選擇一個適當的擺置地點,如此可讓系統發揮最大效益。選擇
地點時,請考慮下列因素:
靠近接地電源插座。
乾淨且無塵。
堅固且不會震動的表面。
通風良好且遠離熱源。
遠離電子裝置 ( 例如空調機、收音機和電視傳輸器等 ) 所產生的電磁場。
檢查包裝盒內容
請先檢查下列包裝盒中的產品項目:
系統
配件盒
上述的任何一項物品若有損壞或缺失,應盡速與經銷商聯絡。
請妥善保存所有產品包裝盒與其他包材,以利未來運送時使用。
打開系統電源
確認系統安裝正確,使用合適電源,並且已連接所有必需週邊設備後,即可打開電腦電源。
請依照以下步驟進行。
按下電源按鈕 。
系統開始啟動並顯示歡迎訊息。然後,會出現連續的開機自我測試 (POST) 訊息。POST
訊息說明了系統是否運作正常。
附註: 若在按下電源鈕之後,系統仍未啟動,
請參閱下一節中啟動失敗之可能原因說明。
除了開機自我測試 (POST) 的訊息外,您還可根據下列情況判斷系統是否處於良好狀態:
前面板上的電源指示燈是否亮起。
鍵盤上的 Num Lock、Caps Lock 和Scroll Lock 指示燈是否亮起。
開機問題
在提供電源後,若系統仍無法啟動,請檢查下列可能原因:
已連接的外接電源線可能鬆掉了。
詳細檢查從電源插座到後面板上電源插孔的電線連接情形。請確認每一條電線都已連接
電源。
接地電源插座沒有電源。請電機人員檢查電源總開關。
內部電纜連接鬆脫或連接錯誤。
檢查內部電纜連接。如果不確定是否可執行這項檢查步驟,請求合格的技術人員協助檢
查。
警告!在進行這項檢查工作前,請確認所有電
源線均已拔掉。
附註: 若您已進行上述的檢查項目,而系統仍
無法啟動,請聯絡經銷商或合格的技術人員,
以取得更多的協助。
關閉系統
有兩種關閉伺服器的方式,透過軟體或硬體。下列的軟體關閉步驟適用於執行 Windows 作
業系統的系統。如需其他作業系統的關閉步驟,請參閱相關的使用者說明文件。
透過軟體關閉系統
1. 同時按下鍵盤上的 <Ctrl> + <Alt> + <Del> 鍵或按一下 Windows 工作列上的「開
始」。
2. 選擇「關機」。
3. 從下拉視窗中選擇「關機」,然後按一下「確定」。
透過硬體關閉系統
如果無法使用軟體關閉伺服器,請按住電源按鈕不放至少四秒鐘。如果少於四秒鐘,只能讓
伺服器進入暫停模式。
環境溫度條件規格
System inlet temperature
Operating
10°- 35°C
Non-operating
-40°- 60°C
Relative humidity
Operating
Non-operating
8 - 80 %
20 - 95 %