Amerec AK Series User manual

AWIEREO
AK
and
3K
Series
with
R30K
Controi
Owners
Manual
AMEREC
STEAMBATH
GENERATORS
(MODELS:
AK4,
AK5,
AK6,
AK7,
AK8.5,
AK10,
3K8,
3K10,3K12,3K14)
SAVE
THIS
MANUAL
Thank
you
for
purchasing
your
new
AMEREC
steam
generator,
If
we
can
be
of
any
assistance
do
not
hesitate
to
cail
our
Service
Department
at
1-800-331'0349
FOR
THE
SAFETY
OF
YOU
AND
YOUR
FAMILY
PLEASE
READ
THE
WARNINGS
TO
THE
RIGHT
AND
ALL
INSTRUCTIONS
BEFORE
USING
YOUR
STEAMBATH.
POST-STEAMBATH
INSTRUCTIONS”
LABEL
OUTSIDE
STEAMBATH
FOR
SAFETY
WARNINGS.
SECT
1.
Assure
that
both
the
power
circuit
and
water
suppiy
to
the
generator
are
ON
2.
To
activate
the
steam
press
the
controi
on.
In
10
to
20
minutes
the
room
shouid
be
comfortable
enough
to
begin
taking
a
steam
bath.
The
unit
will
turn
off
automaticaiiy
in
30
minutes.
The
average
time
spent
taking
a
steam
bath
is
approximately
10
minutes.
3.
Remove
clothing
and
jewelry.
4.
Enter
the
steam
room
and
close
the
door
to
prevent
steam
from
escaping
5.
Relax
and
enjoy
the
warm
steam
releasing
tense
muscles
and
refreshing
the
entire
body
6.
If
your
steam
room
has
a
shower,
a
pleasant
experience
can
be
achieved
by
taking
a
warm
shower
while
in
the
steam.
You
wilt
find
the
contrast
from
water
to
steam
quite
invigorating
7.
Pressing
the
control
while
the
steam
generator
is
operating
will
shut
it
off
8
The
R30K
control
does
not
provide
automatic
temperature
control.
Use
the
on/off
button
to
controi
the
temperature
as
desired
SECTI
ION
2
ES
The
steam
generator,
steam
head,
fittings
and
plumb¬
ing
connections
should
be
inspected
annually
lor
water
leaks
and
damage
The
AK
steam
generator
is
equipped
with
a
drain
valve
forflushing
sediments
from
the
generatortank.
This
procedure
should
be
scheduled
monthly
or
more
often
depending
on
local
water
conditions
and
steam
bath
usage
FLUSHING
PROCEDURE
1.
The
generator
should
be
cool
2.
Turn
control
on.
3
Open
the
drain
valve.
4
The
unit
will
drain
without
heating
the
water
5.
Allow
the
water
to
run
10
minutes
6
Close
the
drain
valve
WARNING
Electric
Shock
Hazard-High
voltage
exists
within
this
equipment
There
are
no
user
serviceable
parts
in
this
equipment.
All
installation
and
service
to
this
equipment
should
be
performed
by
qualified
licensed
personnel.
Do
not
exceed
30
minutes
in
a
steambath.
Excessive
exposure
can
be
harmful
to
your
health.
Excessive
exposure
can
produce
a
rapid
pulse,
Ught-headedness,
weakness
or
fainting.
If
you
become
uncomfortable
or
experience
any
of
the
above
conditions
exit
the
steambath
immediately.
Steambaths
can
put
undue
stress
on
the
body.
Therefore
a
steambath
should
be
used
only
under
a
doctor's
direction
if
you:
Are
pregnant
Have
a
heart
condition
Have
high
blood
pressure
Have
circulatory
problems
Are
under
the
Influence
of
alcohol
Are
under
the
Influence
of
drugs
Have
diabetes
Are
under
the
care
of
a
physician
Are
In
generally
poor
health
Children
should
only
use
the
steambath
under
close
adult
supervision.
Scald
Hazard:
Do
Not
Touch
the
steam
head
or
trim
during
operation
as
they
are
HOT.
Stay
at
least
lEinchesawayfromthe
hot
steam
escaping
from
the
steam
head.
It
is
recommended
that
the
steambath
not
be
operated
for
more
than
one
timer
cycie
wllhoutallowing
the
steam
bath
enclosure
to
cool
because
of
the
following:
Certain
construction
materials
may
be
damaged
by
the
higher
than
normal
heat.
A
scald
hazard
could
he
presented
by
bath
fixtures
overheating.
Be
careful
when
entering
a
steambath.
Escaping
steam
from
an
overheated
steam
room
may
cause
injury.
4209-38
9
-
15-04

AK
and
3K
Series
with
R30K
Controi
Owners
Manual
page
2
NG
GUIDE
The
Troubleshooting
Guide
beiow
is
meant
asa
general
aid
only.
There
are
no
user
serviceable
parts
in
the
generator
All
repairs
should
be
performed
by
a
qualified
service
person
For
additional
assistance
or
the
factory
authorized
service
person
nearest
you
call
AMEREC's
Service
Department
at
1
-800-331
-0349
SYMPTOMS
PROBABLE
CAUSES
ACTION
TO
BE
TAKEN
Nov/alerto
Generator
1
Wait
at
least
10
minutes
alter
turning
on
Control
jConlrof
LlQliled)
NO
Slcam
2
Verily
that
the
water
is
on.
Control
circuit
is
faulty
or
Generator
Is
faulty
3
Verily
that
the
Generator
s
drain
valve
is
closed.
4
If
the
above
4
sleps
do
not
disclose
the
problem
turn
off
the
Generator's
circuit
breaker
Call
AMEREC
s
Service
Department
1
Turn
off
circuit
breaker
(Control
ligtil
off)
Unit
sti!!
makes
steam
Of
Generator
is
faulty
2
Call
AMEREC
s
Service
Depatimeni
Water
runs
out
steam
head
Generator
is
faulty
1
Turn
ofl
circuit
breaker
2
Turn
off
water,
3.
Call
AMEREC’S
Service
Deparlmenl.
tpi
^
Mni
«»ic
DctcniPiion
nAUE
ciiASSii
EfiuiNAl
nonCR
INI'UI
lERumAL
DlOCi
lovcn
riioiii
wiix
wo
laoei
lOVES
ClEUEK’ACCEOS
IWOClEUCIITO
KEUIATISII
niAIIKEI
IDACAE?
IDRACKET
imPLE
BnAIN
llinPlE
lEnUIIIAt
Ol'IIOIIAt
AUTO
TLUIK
lERUIIIAl
DlOC>
;ap
cap,
TimcAO
pnoiECion
AtEl
Ul
RATnio
'RODE
iniPLC
LEVEL
jLEUCNT
nEPLACEUGIIT
EtEUEKT
MLVE
WATER
IIIICT
:iAUP
SELFTISHTEIIVIO
IDtE
WATER
:laup
AUOER
VALVE
UAIfUAl
DRAOl
3AEKET
CIEUCNT
VALVE
PREtSURE
RELIEP
PfiA
PRIIIIBD
CIRCUIT
ASSCUDIY,
A>
1U9
OROUIIO
DOIT
IIMOill}-
HAEKER
IK'LOCK
CDIITflOl
eOllTROL
IIOUEIHB
CABLE
COIITROI
CABLE
EOllTROL
RIDA
E1EAU
IIEAB
DISPEREIOII
HEAD
(NOT
EKOWIII
PLAOARO
SArETT
(HOT
EIIOWIIl
LABEL
WIRE
DlAORAU
FUCEC
lilies
SLO'DLO
|>IQT
SIIOWII)
16)—
•
For
assistance
or
part
orders
please
contact
your
local
AMEREC
Dealer
or
cal!
AMEREC
at
1-800-331
-0349
Please
help
us
serve
you
better
by:
1
Identifying
the
problem
by
using
the
troubleshooting
guide
in
this
manual
2
Read
number
12.
the
UL
Rating
Labe!
to
obtain
your
unit's
model
and
code
number
•When
ordering
parts
please
provide
the
number,
description
and
quantity
needed
When
ordering
wire
assemblies,
please
describe
the
wires
by
color,
location
and/or
their
connection
points
•
Do
not
return
any
materials
to
AMEREC
without
first
contacting
AMEREC
for
a
Return
Authorization
Number
Freight
must
be
prepaid
to
AMEREC
/fAMEREC.
//////
SAUNA
&
STEAM
17683
128th
Ptace
NE,
Building
C
Woodfnvflle,
Washington
98072,
USA
425-951-1120
Fax: