REV. 12-28-17
American Flame: E-Stop Gas Timer
Model: ESTOP1-0H
Description The E-Stop Gas Timer is an emergency shut-off, mechanical timer, and manual shut-off gas valve
designed to be installed on the inlet side of a gas appliance to enable the user to control the time gas is allowed to ow
to a gas appliance. This is a mechanical timer (no batteries or power required) that has the ability to control gas ow for
1-hour (60 minutes) using the ESTOP1-0H model or 2.5-hours (150 minutes) using the ESTOP2-5H model. In addition,
both models have an emergency shut-off (red knob) that enables the user to quickly and easily shut the gas completely
OFF, should the need arise.
The E-Stop Gas Timer body is 4-inches high x 2 ⅞-inches wide x 2 ⅛ -inches deep and can replace a manual shut-off
valve and meet local code requirements as the accessible shut-off valve. It can be use for multiple applications (indoor
or outdoor) from gas re pits, gas grills, gas logs, gas torch lights, etc., wherever a shut-off valve is a requirement or a
specied by a customer.
Model: ESTOP2-5H
E-Stop Gas Timer
AF
A M E R I C A N F L A M E
PUSH TO STOP
TURN TO START
OFF
TURN
PAST 20
40
60
MINUTES
E-STOP1-0
PUSH TO STOP
TURN TO START
OFF
0.5
HOURS
1
1.5
2
2.5
E-STOP2-5
TURN
PAST
Specications
Pipe Size: ½” NPT (2) inlets and (2) outlets Maximum Pressure: ½” PSI
CSA Rated Capacity: 165,000 Btu/Hr at 1” Pressure Drop (NG) Ambient Temperature: 0°F to 175°F (79°C)
Timer Accuracy: 60 Min. +/- 15% or 2.5 Hrs.+/- 15% Inlets: Have fine mesh screens to filter any debris
Multiple Mounting Holes: Uses 3/16-24 machine threads Designed For: Natural or LP Gas (no conversion required)
CSA Certified: Tested to ANSI Z21.21; CSA 6.5
WARNING
• Read these instructions carefully. Failure to follow these instructions completely could damage the product or cause
a hazardous condition.
• Check the ratings given in the instructions and on the product your installing to make sure the E-Stop Gas Timer is
suitable for your application. See description below.
• Installer must be a trained, experienced service technician or gas plumber.
• After installation is complete, check out product operation as provided in these instructions.
American Flame: E-Stop Gas Timer REV. 12-28-17
4 /”
TYP
2 /”
TYP
C
L
C
L
C
L
C
L
3/16 - 24
Mounting Hole
3/16 - 24
Mounting Hole
3/16 - 24
Mounting Hole
3/16 - 24
Mounting Hole
PUSH TO STOP
TURN TO START
OFF
TURN
PAST 20
40
60
MINUTES
BACK VIEW
4”
2 /”
2¹/”
³/”
Fig. 1 E-Stop Gas Timer mounting hole locations applicable to both models.
Mounting
The E-Stop Gas Timer has the ability to be mounted from the side of the body, using the four (4) provided holes (two
mounting holes per side) or using the two mounting hole tabs at the top and bottom of the body when facing forward.
Each mounting hole uses 3/16 - 24 machine screws to secure it into position. Note: We recommend using stainless steel
screws for any outdoor applications. See Fig. 1 for details.
2.0” Inlet @ 1.0” Outlet =
0.5
1.0
1.5
2.0
2.5
3.0” Inlet @ 1.5” Outlet =
4.0” Inlet @ 2.0” Outlet =
250,000 275,000 300,000 325,000 350,000 375,000 400,000
Btu/Hr
Pressure Drop & Capacity Curve
E-Stop Timer (LP Gas)
5.0” Inlet @ 2.5” Outlet =
3.0
425,000 450,000
Note: Pressure drop information listed is generated in American Flame lab and is to be used as reference only.
Table 2 Pressure drop and capacity for LP Gas).
2.0” Inlet @ 1.0” Outlet =
0.5
1.0
1.5
2.0
2.5
3.0” Inlet @ 1.5” Outlet =
4.0” Inlet @ 2.0” Outlet =
150,000 175,000 200,000 225,000 250,000 275,000 300,000
Btu/H
Pressure Drop & Capacity Curve
E-Stop Timer (Natural Gas)
Table 1 Pressure drop and capacity for Natural Gas.
REV. 12-28-17
American Flame: E-Stop Gas Timer
Installation
The recommended installation position is up-right as
shown in Fig 2, view "D". It has two (2) inlet and two (2)
outlet gas connections. The diagrams below provide
possible ways to plumb the E-Stop (See Fig. 3). Two (2)
½” NPT plugs are provided with the E-Stop. Plug the inlet
and outlet connections not being used for the application.
Connect gas supply to the inlet with the arrow
pointing into the valve. Connect outlet side to the gas
appliance (See Figs. 2 & 3 for details).
NOTE: Conduct a gas leak test on the E-Stop Gas Timer
after plumbing is complete.
Operation
TO TURN ON
Step 1: Rotate the clear timer dial past 20 (ESTOP1-0H) or
past 0.5 (ESTOP2-5H) to set the time. Timer will begin “ticking”
when the dial is turned while the countdown time is set.
Step 2: Turn red knob clockwise (about a ¼ turn) until it pops
outward. Gas will now ow to enable you to light the appliance.
TO TURN OFF: Let timer expire or simply press red knob
inward until it stops. The red knob will lock down with a “click”
and stop gas ow. See Fig. 4 and Fig. 5 on following page.
Note: Do not force the timer dial to the OFF position after time
is set (This will weaken the spring inside the timer body and
affect the accuracy of the time).
Timer Dial:
Rotate clockwise to
start time. Adjust dial to
desired time frame.
Red Knob: Turn
clockwise and knob
will “pop” up to allow
gas flow.
PUSH TO STOP
TURN TO START
OFF
TURN
PAST
20
40
60
MINUTES
Fig. 4 E-Stop operation.
BACK VIEW
Inlet
Inlet
Outlet
Outlet
SIDE IN SIDE OUT
BACK
IN
BACK
OUT
Fig. 2 Inlet and outlet connections.
“A-C”Shows Top View of E-Stop
“D” Shows Front View of E-Stop
Inlet
Outlet
D
PUSH TO STOP
TURN TO START
OFF
TURN
PAST
20
40
60
MINUTES
Inlet
Outlet
C
Inlet
Outlet
B
Inlet
Outlet
A
Fig. 3 Plumbing options
American Flame: E-Stop Gas Timer REV. 12-28-17
FOR TECHNICAL U.S. INQUIRIES CANADIAN INQUIRIES
SERVICE: (855) 498-8324 or (260) 459-1703 (877) 472-3923
For Sales: (888) 672-8929
Website: www.skytechpg.com
Limited Warranty
Skytech Products Group (American Flame) warrants the E-Stop Gas Timer for 12 months from the date of purchase or installation to
the original purchaser to be free from defects in materials and workmanship. It is designed for INDOOR OR OUTDOOR USE.
Damage to the E-Stop Gas Timer caused by accident, misuse, abuse, or installation error, whether per formed by a
contractor, Service Company, or owner, is not covered by this warranty. American Flame will not be responsible for labor charges
and/or damage incurred in installation, repair, replacement, or for incidental or consequential damage. Some states, provinces, and
nations do not allow exclusion or limitations of incidental or consequential damages, so the above limitations or exclusions may not
apply. This warranty gives you specic legal rights. You may also have other rights that vary by state, province, or nation.
American Flame
9230 Conservation Way
Fort Wayne, IN 46809
(260) 459-1703
Symptom Remedy
No gas ow 1. Rotate dial beyond the "turn past" position.
2. Ensure red knob is protruding outward in ON position.
3. Has time has expired on timer? If so re-start timer again.
4. Ensure primary gas supply is turned ON.
5. Ensure the gas timer is plumbed properly.
6. Look for any physical damage.
7. Ensure other gas valves before or after the timer are operating.
8. Check inlet mesh screen for debris blockage.
Gas ow won't stop 1. Timer plumbed backwards? Check inlets and outlets on timer.
2. Excessive gas pressure exceeding the ½” PSI maximum pressure.
3. Plumbed into both inlet lines and not one of the outlets.
4. Look for any physical damage. If so, replace timer.
Red Knob Down = Gas OFFRed Knob Up = Gas ON
Side View Side View
Fig. 5 E-Stop Gas Timer red knob positions
TROUBLESHOOTING

This manual suits for next models

1

Popular Timer manuals by other brands

Zamel EXTA ASP-01 instruction manual

Zamel

Zamel EXTA ASP-01 instruction manual

Intermatic EI600 Series Installation and user instructions

Intermatic

Intermatic EI600 Series Installation and user instructions

Competition Electronics POCKET PRO operating manual

Competition Electronics

Competition Electronics POCKET PRO operating manual

CHDD KG316T quick start guide

CHDD

CHDD KG316T quick start guide

Airpress ACW user manual

Airpress

Airpress ACW user manual

Elliwell EWDR 72 General description

Elliwell

Elliwell EWDR 72 General description

F&F PCZ-528.3 manual

F&F

F&F PCZ-528.3 manual

ANV APT2-S manual

ANV

ANV APT2-S manual

Bibby Sterilin Techne FGT5 Instructions for use

Bibby Sterilin

Bibby Sterilin Techne FGT5 Instructions for use

Anslut 006053 operating instructions

Anslut

Anslut 006053 operating instructions

Forge Electronics E-ZEE ECL mini quick start guide

Forge Electronics

Forge Electronics E-ZEE ECL mini quick start guide

Orbit 62015 Installation and user guide

Orbit

Orbit 62015 Installation and user guide

Intermatic DT620CL Series Installation and user instructions

Intermatic

Intermatic DT620CL Series Installation and user instructions

Omron H3CR-A8 instruction sheet

Omron

Omron H3CR-A8 instruction sheet

Danfoss 852 User instructions

Danfoss

Danfoss 852 User instructions

Elkay Energy sense operating instructions

Elkay

Elkay Energy sense operating instructions

Viessmann 5208 Operation manual

Viessmann

Viessmann 5208 Operation manual

Delixi KG316TQ user manual

Delixi

Delixi KG316TQ user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.