Specications: Sync Bluetooth™ Digital Clock/Timer .............................................................................. 3
Device specications ............................................................................................................... 3
Digital Clock/Timer 120 VAC power, weight, and dimension specications ......................................... 5
Install and operation overview: Sync Bluetooth Digital Clocks & Timers ...................................................... 6
About Sync Bluetooth Devices ................................................................................................... 6
Add a Clock Mode .................................................................................................................. 6
Post-install operation .............................................................................................................. 7
Install Digital Clock/Timer: Wall mount with tilt bracket ........................................................................... 8
Tilt bracket mounting dimensions .............................................................................................. 8
Assemble and mount to tilt bracket ............................................................................................ 9
Remove digital clock/timer from tilt bracket ............................................................................... 10
Digital Clock/Timer wall mount with keyhole installation ....................................................................... 11
Mounting dimensions ............................................................................................................ 11
Directly mount a clock/timer to the surface of a wall .................................................................... 12
Digital Clock/Timer dual-sided installation ......................................................................................... 13
Supplied components ............................................................................................................ 13
Mounting dimensions ............................................................................................................ 13
Assemble and mount a dual-sided digital clock/timer ................................................................... 14
Remove from dual mount bracket ............................................................................................ 15
Digital Clock/Timer ush mount installation ....................................................................................... 16
Supplied components ............................................................................................................ 16
Dimension specications ....................................................................................................... 16
Install ush mount clock/timer ................................................................................................ 16
Timer Control Switch installation ..................................................................................................... 19
Step 1 (code blue timer only): Wire timer to code blue system ........................................................ 19
Step 2: Attach timer to Timer Control Switch .............................................................................. 19
Step 3: Mount Timer Control Switch to junction box ..................................................................... 20
Operate a Code Blue Timer ............................................................................................................. 21
Code Blue Timer operation overview ......................................................................................... 21
Technical Support ......................................................................................................................... 23
Support through Primex Certied Sales and Service Partners ......................................................... 23
Primex Technical Support ...................................................................................................... 23
IMPORTANT SAFETY INSTRUCTIONS ............................................................................................... 24
REGULATORY APPROVALS ............................................................................................................. 25
RADIO STANDARDS SPECIFICATION (RSS) ........................................................................................ 27
European Union Declaration of Conformity and Restrictions .................................................................. 28
TWO YEAR LIMITED WARRANTY ..................................................................................................... 29
Page 2

Specications: Sync Bluetooth™ Digital Clock/Timer
Device specications
AC power supply 120 VAC (100-240)/ 50–60 cycle, 10 ft. (3.0 m) cord with two-prong plug, UL/cUL listed
Enclosure Enclosure: ABS plastic
Junction box: UL listed (UL 50E 1st Ed; listing number E469550)
Bluetooth® Wireless
Communication
Protocol
Bluetooth® Low Energy (BLE) Wireless Technology, version 4.1
Bluetooth Range: up to 100 ft. (30 meters)
Operation 12 or 24-hour time display
PM indicator light
Alternating time and date display option
LED digit dimmer option (100%, 75%, 50%, 25%)
Automatically adjusts for Daylight Saving Time (DST)
Clock connects to a Sync Bluetooth mesh network to send status, synchronize received
UTC time to its Time Zone offset and DST rules, and receive OneVue setting updates.
If power is interrupted, the clock stops until power resumes. Upon resumption of power,
the clock self-corrects to the current time. Retains time in memory for up to one hour.
Environment Operating temperature: 32° to 95° F (0° to 35° C)
Storage temperature range: -4° to 158° F (-20° to 70° C)
Certications FCC, CE, and IC compliant
Components specifications
The backside of a Levo Digital Clock/Timer houses the mounting, power, connection inputs, and setting panel.
Page 3

A. Key-Hole Mount (2)
B. AC power supply and power cord with 2-prong plug (AC model). Power cord strain relief assembly with supplied
washer and screw.
C. RJ45 port (PoE model)
D. RJ11 port (elapsed timer and code blue timer model): connection to supplied Timer Switch Control
E. 4 pin port (code blue timer model): connection to supplied 4 pin 30 in. (76.2 cm) connector
F. Setting panel (options vary by model): Mini-USB port, manual dimmer display button, Reset (check-in) button
Page 4

Digital Clock/Timer 120 VAC power, weight, and dimension specications
Digital Clocks/Timers are shipped from the factory with a power supply and power cord with a two-prong plug. The
power plug may be removed and the cord cut to length for hardwired (pigtail) installation. Pigtail installation requires a
120V~ power line in a junction box installed by a licensed electrician. Leave a minimum of 6 in. (15 cm) of cord inside
the junction box.
Specications
Clock Type Weight Max. Current Draw Height (A) Width (B) Depth (C)
2.5" (6.4 cm)
4-digit
1.8 lb (0.8 kg) 135 mA 5.0" (12.7 cm) 10.8" (27.3 cm) 2.2" (5.6 cm)
2.5" (6.4 cm)
6-digit
2.0 lb (0.9 kg) 170 mA 5.0" (12.7 cm) 13.8" (34.9 cm) 2.2" (5.6 cm)
4" (10.16 cm)
4-digit
3.9 lb (1.8 kg) 185 mA 8.0" (20.3 cm) 17.9" (45.5 cm) 2.4" (6.1 cm)
4" (10.16 cm)
6-digit
4.6 lb (2.1 kg) 205 mA 8.0" (20.3 cm) 23.3" (59.2 cm) 2.4" (6.1 cm)
Page 5

Install and operation overview: Sync Bluetooth Digital Clocks & Timers
OneVue Sync Bluetooth devices are designed to provide ease of installation, requiring no end user conguration, simply
take-out-of the box and install. The only operation dependency is its connection to an available Sync Bluetooth mesh
network.
About Sync Bluetooth Devices
• Each device is equipped with a Bluetooth Low Energy (BLE) Wireless Technology radio component that allows it to
establish a wireless connection to a Sync Bluetooth mesh network.
• Each device is identied by a unique Device ID, allowing it to receive its unique settings managed in OneVue, and
authenticate and connect to the mesh network.
• A Bridge is the only system device that connects to an Ethernet or Wi-Fi network. Upon its network connection, it
connects to a NTP Server to receive UTC time and checks-in to OneVue. During each check-in, it sends device data
received from its last connection to the mesh network and downloads any pending setting updates. Pending setting
updates are then transmitted to devices during its next connection to the mesh network.
Add a Clock Mode
Upon rst-power up at its installation location, a clock and repeater enters Add a Clock mode as described below.
1. Once powered on at its installation location, the device continuously searches for an available Sync Bluetooth
mesh network.
It may take up to 15 minutes for a device to authenticate and connect to an available mesh network. We
recommend to continue installing additional devices, while other devices establish their connection to the mesh
network.
2. Once a device has authenticated with the mesh network, it establishes a communication path either to another
Sync Bluetooth device or directly to a Bridge available within the mesh network.
3. Once connected, the device receives the New Clock Time Zone and sets its time. For an analog clock, its hands
perform one full revolution past 12:00 and then sets its time.
• During its rst connection to the mesh network, its unique Device ID is added to the mesh network.
• If a Bridge is in 8-hour deployment mode, within 30 minutes of receiving a new Device ID, the Bridge connects to
your facility's network and sends the new Device ID to OneVue. The new device is added to your OneVue
account.
• If a Bridge is not in 8-hour deployment mode, the new device is added to your OneVue account within 24 hours to
7 days.
4. When the Bridge connects to OneVue, the new device default settings are downloaded to the Bridge.
5. Upon its next connection to the mesh network, the Bridge automatically sends updated device settings received for
each device based on their Device ID.
Page 6

In summary, from the time a clock or repeater device is rst powered on at its install Location and connects to the
mesh network, it receives and sets its time within 15 minutes. If a Bridge is in 8-hour deployment mode, a new device is
added to your OneVue account within 30 minutes, and when not in 8-hour deployment mode it may take up to 24 hours
to 7 days.
Battery-operated clock only: When a clock cannot establish a connection to a mesh network to receive time, its
estimated battery life is reduced to 90 days.
Post-install operation
Once a Bridge has connected to OneVue and the Bluetooth clocks and/or repeaters have authenticated and connected
to a Sync Bluetooth mesh network, the devices operate as described below.
1. Once a day, at a system dened time, a Bridge connects to your facility’s network to receive UTC time from a NTP
Server and check-in to OneVue to download device setting updates.
2. Once a day, at a system dened time, each Sync Bluetooth device automatically establishes a wireless
communication path to either another device to build the Sync Bluetooth mesh network.
• Clock and repeater statuses are forwarded to a Bridge either by its communication path to another clock,
repeater or directly to a Bridge.
• Clocks and repeaters receive setting updates and synchronizes received UTC time to its Time Zone offset and
DST rules.
3. Once the Sync Bluetooth mesh network has completed its daily build, a Bridge connects to your facility's network to
send all received device status data to OneVue.
Page 7

Install Digital Clock/Timer: Wall mount with tilt bracket
A Digital Clock/Timer can be wall mounted at a 4° or 18° angle with use of the supplied tilt bracket.
Tilt bracket mounting dimensions
• Dimension D: Clock screw hole spacing.
• Dimension E: Distance to wall surface for 4° mounting bracket
• Dimension F: Distance to wall surface for 18° mounting bracket
• Dimension G/H: Mounting bracket screw hole spacing.
Dimension
Clock/Timer Model A B C D E F G H
2.5” 4-digit - 4° bracket 4.8” 10.6” 2.1” 6.0” 0.38” – 0.63” N/A” 8.0” 2.5”
2.5” 6-digit - 4° bracket 4.8” 13.6” 2.1" 6.0” 0.38” – 0.63” N/A 8.0” 2.5”
2.5” 4-digit - 18° bracket 4.6" 10.6" 2.2" 6.0" N/A 2.1" 9.5" 2.5"
2.5” 6-digit - 18° bracket 4.6" 13.6" 2.1" 6.0" N/A 2.1" 9.5" 2.5"
4” 4-digit wall mount 8.0” 17.9” 2.4” 14” 0.4 – 0.9” N/A 12.0” 4.0”
4” 6-digit wall mount 8.0” 23.3” 2.4" 14” 0.4 – 0.9” N/A 12.0” 4.0”
Page 8

Assemble and mount to tilt bracket
NOTE
Hardwired (pigtail) install: AC-powered clocks are supplied with a power cord with a two-prong plug.
The two-prong plug may be removed for a hardwired (pigtail) installation. Hardwired installation
requires a 120V~ power line in a junction box installed by a licensed electrician. Leave a minimum of 6
in. (15 cm) of cord inside the junction box. The tilt bracket has a center pass-through hole for the 120V~
pigtail. If a junction box is present, the tilt bracket has mounting holes spaced to allow direct
attachment of the tilt bracket to the junction box cover plate screw holes.
1. Mount the tilt bracket directly to the wall with the four #10 screws and anchors (supplied). To determine the
spacing of the screws, refer the mounting dimensions.
2. Latch the clock onto the tilt bracket. The top latch position determines the tilt degree.
Page 9

Remove digital clock/timer from tilt bracket
• 2.5" model: From the top of the bracket using a screwdriver press each hook down to release the clock and pull out to
unsnap bottom hinges.
• 4” model: From the top of the bracket, insert a thin screwdriver into each notch and gently move the screwdriver
sideways to unlock the clock, pull clock forward and up to unsnap, and lift out.
Page 10

Digital Clock/Timer wall mount with keyhole installation
A Digital Clock/Timer can be mounted directly to the surface of a wall by use of the clock keyhole mounts and the
supplied screws and anchors.
Mounting dimensions
• Dimension D: Clock screw hole spacing.
• Dimension E: Distance to wall surface for 4° mounting bracket
• Dimension F: Distance to wall surface for 18° mounting bracket
• Dimension G/H: Mounting bracket screw hole spacing.
Dimension
Clock/Timer Model A B C D E F G H
2.5” 4-digit - 4° bracket 4.8” 10.6” 2.1” 6.0” 0.38” – 0.63” N/A” 8.0” 2.5”
2.5” 6-digit - 4° bracket 4.8” 13.6” 2.1" 6.0” 0.38” – 0.63” N/A 8.0” 2.5”
2.5” 4-digit - 18° bracket 4.6" 10.6" 2.2" 6.0" N/A 2.1" 9.5" 2.5"
2.5” 6-digit - 18° bracket 4.6" 13.6" 2.1" 6.0" N/A 2.1" 9.5" 2.5"
4” 4-digit wall mount 8.0” 17.9” 2.4” 14” 0.4 – 0.9” N/A 12.0” 4.0”
4” 6-digit wall mount 8.0” 23.3” 2.4" 14” 0.4 – 0.9” N/A 12.0” 4.0”
Page 11

Directly mount a clock/timer to the surface of a wall
Most building codes prohibit the use of hardwired power connections for devices that can be removed without tools. A
clock/timer mounted directly to a wall is required to have a standard power plug.
• Mount the clock/timer directly to the wall with the two #10 screws and anchors (supplied). To determine the
spacing of the screws, refer to the mounting dimensions.
When a clock or repeater is powered-on, it enters Add a Clock Mode to initiate a connection to the Sync Bluetooth mesh
network.
Page 12

Digital Clock/Timer dual-sided installation
A dual-sided Digital Clock/Timer consists of two single-sided clocks/timers and a dual bracket kit. The kit includes a
dual housing bracket, a ange that mounts to ceiling or wall, and the hardware necessary to complete the installation.
Using the kit, you combine the two single-sided clocks to create a dual-sided clock. The 4” x 6 digit version of the digital
clock cannot be wall-mounted.
NOTE
The two clocks function independently of each other and are monitored and managed as two single
devices in OneVue.
Supplied components
Quantity Component
1 Flange (mounts to ceiling or wall)
1 Bracket (bolts to ange and to which two clocks are mounted)
Required (not supplied): electrical junction box, cord retaining clips.
Mounting dimensions
Mounted Dimensions
Clock Type Width from Wall (A) Height from Ceiling (B) Depth of 2 Clocks (C)
Dual 2.5” (6.4 cm)
4-digit
13.8” (35.1 cm) 8.0” (20.3 cm) 5.9” (15.0 cm)
Dual 2.5” (6.4 cm)
6-digit
16.8” (42.7 cm) 8.0” (20.3 cm) 5.9” (15.0 cm)
Dual 4” (10.16 cm)
4-digit
20.9”(53.1 cm) 11.0” (27.9 cm) 6.3” (16.0 cm)
Dual 4” (10.16 cm)
6-digit
N/A* 11.0” (27.9 cm) 6.3” (16.0 cm)
*4” 6-digit clock is not available as wall mount.
Page 13

Assemble and mount a dual-sided digital clock/timer
1. On the wall or ceiling, measure and drill holes with the correct spacing to mount the ange over the junction box.
2. Attach the ange to the wall or ceiling using the toggle anchors and the longer machine screws provided.
Wall-mount: if the mounting location is outside of the junction box, break off or cut openings in the ange to route
power cords.
3. Attach the bracket to the ange using the supplied shorter machine screws, nuts, and washers.
4. For wall mount only, knock out power cord break.
5. Wire clocks to main power, using cord retaining clips to dress wires.
6. Align the clock to the bracket hooks and hinges and snap into place.
When a clock or repeater is powered-on, it enters Add a Clock Mode to initiate a connection to the Sync Bluetooth mesh
network.
Page 14

Remove from dual mount bracket
2.5” model: From the top of the bracket, using a screwdriver press each hook down to release the clock. Then pull out
to unsnap bottom hinges.
4” model: From the top of the bracket, insert a thin screwdriver into each notch and gently move the screwdriver
sideways to unlock the clock, pull clock forward and up to unsnap, and lift out.
Page 15

Digital Clock/Timer ush mount installation
A ush mount model can be installed onto a new or existing wall surface.
Supplied components
Quantity Component
1 Flush mount junction box
Material: ABS plastic, color black, and UL Rated 94-V0
1 Bezel
Material: ABS plastic, color black, and UL Rated 94-V0)
4 #10 Phillips Flat Head Screw
4 Drywall Anchor
Dimension specications
Clock Type Weight Max. Current
Draw
Width (A) Height (B) Depth (C)
2.5" (6.4 cm) 6-
digit
2.0 lb (0.9 kg) 170 mA 16.8" (42.7 cm) 6.5" (16.5 cm) 3.4" (8.6 cm)
Install ush mount clock/timer
1. Mount the junction box.
•New wall surface
Mount junction box to wall studs using four common drywall screws (not supplied), as shown in Figure 1, “New
wall surface assembly illustration” [18].
Remove the applicable conduit knockout(s) for the incoming AC power (PoE optional: for AC backup power use
only) and the timer input for a timer model only. Do not remove knockouts that you will not be using.
Page 16

•Existing wall surface
Cut a 14.4 in. (36.5 cm) wide x 5.8 in. (14.7 cm) high wall opening between two wall studs, as shown Figure 2,
“Existing wall surface assembly illustration” [18]. Securely mount junction box to all studs using four common
drywall screws (not supplied) at each of the corner locations.
Remove the applicable conduit knockout(s). Including the incoming AC power conduit (PoE optional: for AC
backup power use only) and timer input conduit (required for timer models only). Do not remove knockouts that
you will not be using.
NOTE
For timer models only: AC wiring is required to be located to the right side of the junction box
divider and the time input to the left side.
2. Connect the conduit connection(s) to the junction box.
3. New wall surface only: Cut out a 14 in. (35.5 cm) wide x 5.25 in. (13.3 cm) high wall opening for placement of the
clock assembly. Trim opening if necessary.
4. Gently snap the ush mount bezel onto the front of the clock/timer.
5. AC-powered device: connect and apply AC power.
6. Secure all wiring.
For timer models, secure and complete timer input connections.
7. Insert the clock assembly into the wall opening.
8. Level the clock assembly within wall opening and secure bezel to the wall surface using the four screws and
anchors (supplied) at each of the corner locations.
When a clock or repeater is powered-on, it enters Add a Clock Mode to initiate a connection to the Sync Bluetooth
mesh network.
Page 17

Figure 1. New wall surface assembly illustration
Figure 2. Existing wall surface assembly illustration
Page 18

Timer Control Switch installation
Elapsed Timers and Code Blue Timers include a three-button Timer Control Switch that controls end-user timer events.
• InfoBoards can operate as an Elapsed Timer with both count up and count down options. The three-button Timer
Control Switch allows a user to start, pause, stop, and reset the count events, and set an event to begin at a specic
time increment. When not in an active count event, an InfoBoard displays synchronized time and general messaging.
Step 1 (code blue timer only): Wire timer to code blue system
The wiring is dependent on the type of code blue system identied below.
For code blue systems that apply a voltage to start a code blue event.
1. Wire the timer four pin connector RED (Positive Code Blue Input) and BLACK (Negative Code Blue Input) wires to
the code blue system. Cap off the WHITE and GREEN wires separately.
2. An input voltage of 5-120V (AC or DC) can be used. When using DC, be sure to use the correct polarity; RED wire is
positive and the BLACK wire is ground. Code Blue start/stop events are triggered by the application of voltage
across the code blue input wires.
For code blue systems that use a dry contact and do not inject a voltage
• Wire the timer four pin connector GREEN (Ground) and BLACK (Negative Code Blue Input) wires together and wire
the WHITE (12VDC) and RED (Positive Code Blue Input) wires to the code blue system dry contact.
Step 2: Attach timer to Timer Control Switch
The Timer Control Switch is not connected to the device during shipment. The cable length can be extended up to 100
ft. (30.4 m).
Using the supplied 20 ft. (6.0 m) RJ11 cable, connect the timer to the Timer Control Switch.
Page 19

Step 3: Mount Timer Control Switch to junction box
Timer Control Switch is required to be mounted to a single-gang junction box (not supplied). The junction box
dimension is typically 2.25 in. x 2.75 in. x 4 in. (5.72 cm x 6.99 cm x 10.16 cm).
Page 20
This manual suits for next models
2
Table of contents
Other Primex Timer manuals
Popular Timer manuals by other brands

Auber Instruments
Auber Instruments JSL-72 instruction manual

Orbit
Orbit 94066 Installation and user guide

Insportline
Insportline CF100 user manual

Train By Fire
Train By Fire JI9D-1R owner's manual

Digital Game Technology
Digital Game Technology DGT 2010 Repair

Learning Resources
Learning Resources Time Tracker user guide