Installation Instructions
Vault w/ visor C-Scroll w/ visor Roundel w/ visor
These installation instructions are valid with the above Ametrix styles
Warning
: Before startin any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician. Do not
mount fixtures vertically.
Small, INDOOR
CPP/CPS
(Continuous Pendant)
Visor and Non-Visor
Sheet 5 of 5
ADY071477 REV A (ECN080352)
(Custom row configurations are available however pricing may be affected)
Continuous Pendant Row Layouts
Nominal
Row
Length
(ft)
Overall
Row
Length:
Pendant
(ft)
Row Breakdown/
Installation Sequence
Nominal
Row
Length
(ft)
Overall
Row
Length:
Pendant
(ft)
Row Breakdown/ Installation
Sequence
32.6 2C 27 25.4 3C,4C,4C,4C,4C,3C
43.6 3C 28 27.4 4C,4C,4C,4C,4C,4C
54.6 4C 29 28.9 4C,4C,3C,3C,3C,4C,4C
65.1 2C,2C 30 29.9 3C,4C,4C,4C,4C,4C,3C
76.1 2C,3C 31 30.9 4C,4C,4C,3C,4C,4C,4C
87.1 3C,3C 32 31.9 4C,4C,4C,4C,4C,4C,4C
98.1 3C,4C 33 31.9 4C,4C,4C,4C,4C,4C,4C
10 9.1 4C,4C 34 32.5 2C,4C,4C,4C,4C,4C,4C,2C
11 10.7 3C,3C,3C 35 34.5 3C,4C,4C,4C,4C,4C,4C,3C
12 11.7 4C,2C,4C 36 35.5 4C,4C,4C,4C,3C,4C,4C,4C
13 12.7 4C,3C,4C 37 36.5 4C,4C,4C,4C,4C,4C,4C,4C
14 13.7 4C,4C,4C 38 38.0 4C,4C,4C,3C,3C,3C,4C,4C,4C
15 14.2 3C,3C,3C,3C 39 39.0 3C,4C,4C,4C,4C,4C,4C,4C,3C
16 15.2 3C,3C,3C,4C 40 39.0 3C,4C,4C,4C,4C,4C,4C,4C,3C
17 16.2 3C,4C,4C,3C 41 40.0 4C,4C,4C,4C,3C,4C,4C,4C,4C
18 17.2 4C,4C,4C,3C 42 41.0 4C,4C,4C,4C,4C,4C,4C,4C,4C
19 18.2 4C,4C,4C,4C 43 42.6 4C,4C,4C,4C,3C,3C,3C,4C,4C,4C
20 19.8 4C,3C,3C,3C,4C 44 43.6 3C,4C,4C,4C,4C,4C,4C,4C,4C,3C
21 20.8 3C,4C,4C,4C,3C 45 44.6 4C,4C,4C,4C,4C,3C,4C,4C,4C
22 21.8 4C,4C,3C,4C,4C 46 45.6 4C,4C,4C,4C,4C,4C,4C,4C,4C,4C
23 21.8 4C,4C,3C,4C,4C 47 46.1 3C,3C,4C,4C,4C,4C,4C,4C,4C,3C,3C
24 23.4 2C,4C,4C,4C,4C,2C 48 47.1 4C,4C,4C,4C,3C,3C,3C,4C,4C,4C,4C
25 23.4 2C,4C,4C,4C,4C,2C 49 48.1 3C,4C,4C,4C,4C,4C,4C,4C,4C,4C,3C
26 25.4 3C,4C,4C,4C,4C,3C 50 49.1 4C,4C,4C,4C,4C,3C,4C,4C,4C,4C,4C