AQS-HHA1-D
Advanced Microwave Products
8748 Technology Way
Reno, NV 89521
Phone: (775) 345-9933
How to Congure Your Amplier
The HHA1 power amplier does not require any conguring unless it includes optional multiple RF
power output levels. If included, the power level is set using pin 7 and 8 of the MDM-9P connector
shown above. Reference the Output Power Conguration table below to determine whether each
wire is to be left open (or driven to 3.3 Vdc by an external device) or grounded (or driven to below
0.6 Vdc by an external device) to command the unit to the desired output level. If the HHA1 power
amplier is commanded to a power level with which the unit is not equipped, the unit will default
to standby (disabled) until a valid power level command is applied. See the product manual for
more details.
Power Select 1 Power Select 2 Output Power
Ground Ground Standby
Ground Open 2 W
Open Ground 5 W
Open Open 10 W
Output Power Conguration
SMA Female
RF Input
SMA Female
RF Output
Wiring Your HHA1 Power Amplier
MDM-9P
Power & Conguration
1:
2:
3:
4:
5:
6:
7:
8:
9:
+11 to 16 VDC Input
Ground
Ground
Ground
Enable (Open=On, Ground (or <1.5 Vdc)=O)
Ground
Power Select 1 (Open=High, Ground (or <0.6 Vdc)=O)
Power Select 2 (Open=High, Ground (or <0.6 Vdc)=O)
Ground
1 5
6 9