AQS-HSF1-D
Advanced Microwave Products
PO Box 1437
2465 Old Highway 40 West, Suite 200
Verdi, NV 89439
How to Congure Your Amplier
The HSF1 power amplier does not require any conguring unless it includes optional multiple RF
power output levels. If included, the power level is set using the green and blue wires shown above.
Reference the Output Power Conguration table below to determine whether each wire is to be left
open (or driven to 3.3 Vdc by an external device) or grounded (or driven to below 0.6 Vdc by an
external device) to command the unit to the desired output level. If the HSF1 power amplier is
commanded to a power level with which the unit is not equipped, the unit will default to standby
(disabled) until a valid power level command is applied. See the product manual for more details.
Power Select 1 Power Select 2 Output Power
Ground Ground 250 mW
Ground Open 500 mW
Open Ground 1 Watt
Output Power Conguration
Wiring Your HSF1 Power Amplier
SMA Female
RF Input
SMA Female
RF Output
Hirose DF13
Power & Conguration
1:
2:
3:
4:
5:
6:
7:
8:
+11 to 16 VDC Input
Ground
Power Select 1 (Open=High, Ground (or <0.6 Vdc)=O )
Ground
Power Select 2 (Open=High, Ground (or <0.6 Vdc)=O )
Ground
Ground
Enable (Open=On, Ground (or <1.5 Vdc)=O)
Red
Black
Green
Green/White
Blue
Blue/White
Black
White