Ampetronic Loopworks Measure R1 User manual

Quick-Start Guide
& R1 Handbook
Measure
Design
Connect
Learn
UP18301-2

1. Sign up for Loopworks™
If you haven’t done so already, create an
account to access the Loopworks™ online
environment.
This stage is optional, and you can use the
Measure App + Receiver in simple Meter mode,
but will need an account to access the full range
of Loopworks functions and to save data or
record audio. Create an account at:
https://loopworks.ampetronic.com
Measure R1
www.ampetronic.com
Measure R1
www.ampetronic.com
2. Purchase Receiver
If you haven’t done so already, you will need to
purchase a Loopworks Measure Receiver.
The Receiver contains a Telecoil and enables your
iOS device to measure electromagnetic elds. The
Loopworks Measure App will not function without
a Receiver.
Order at:
ampetronic.com/products

3. Download the FREE App
If you haven’t done
so already, you will
need to download
the FREE Loopworks
Measure App from
the Apple App Store,
using your iOS
device.
TESTS
Background Noise
Filed Strength
Frequency Response
Live Signal
System Noise
Overspill
QUESTIONS
Signage
Sta Training
SIGNAL TYPES
Sine
Pink
Combi
Live
No Signal
System O
ACCEPTANCE
Good / Pass
Qualied Pass
Unacceptable / Fail
Help
Alignment Alert
MENU
Signal Menu
Capture
Meter
Certify
Settings
Reset
Results
Overall System Ver-
tics
Freq Noise
Field Results
4. Connect the Receiver
Start your new App and plug the Receiver into
the headphone socket of your iOS device to
activate it.
Follow the on-screen instructions to allow
access to the microphone and enter the label
number (digits only) printed on the side off the
Receiver.
Measure R1
www.ampetronic.com
Home Advanced
Background
Noise
Frequency
Response
Field
Strength
Test
Perimeter Loop
Unacceptable
-5.2 db
-22
0
+8
+2
1 kHz / 400 mA/m
+1
+3
+4
+5
+7
+6
-1
-2
-3
-4
-5
-12 -9
Instructions
FSM
Project: Ampetronic Head Office
Start Test Test Points SettingsResults
Freq
Field Noise
-40
-35
-30
-25 -20 -15 -10 -5
0
+5
+10
Live +40.0dBL
Save
Reset
1 kHz / 400 mA/m
Field Strength
Hold -20.0dBL
PASS
System: Meeting Room 1
Audio
Type
Signal
Area Coverage
Combi

5. Calibrate Receiver
Follow the on-screen instructions to
calibrate the receiver against your
iOS device’s settings.
This is an important function to allow
accurate meter readings to be taken.
Home Advanced
Background
Noise
Frequency
Response
Field
Strength
Test
Perimeter Loop
Unacceptable
-5.2 db
-22
0
+8
+2
1 kHz / 400 mA/m
+1
+3
+4
+5
+7
+6
-1
-2
-3
-4
-5
-12 -9
Instructions
FSM
Project: Ampetronic Head Office
Start Test Test Points SettingsResults
Freq
Field Noise
-40
-35
-30
-25 -20 -15 -10 -5
0
+5
+10
Live+40.0dBL
Save
Reset
1kHz / 400 mA/m
Field Strength
Hold-20.0dBL
PASS
System: Meeting Room 1
Audio
Type
Signal
Area Coverage
Combi
6. Sign in to Loopworks
Unless you intend to use the Loopworks™
Measure App as a simple meter (no recording of
data or audio and testing guides) you will need
to sign into the account you created at stage 1.
Press the Settings icon and enter the ‘Change
User’ screen to sign in.
Synchronise with your account by entering the
Projects Menu at the top of the screen and
selecting “synchronise” to save or retrieve data.

Handbook Contents
• Safety
• Introduction
• Overviewofunit
• Operationofunit
• Troubleshooting
• TechnicalSpecications
• Warranty&Calibration
• DeclarationofConformity
Box Contents
• 1xLoopworksMeasureR1
• 1xPouch
• 1xQuick-StartGuide&
Handbook
This symbol is used to alert the user to important
operating or maintenance instructions.
The lightning bolt triangle is used to alert the user
to the risk of electric shock.
SAFETY
1.Itisimportanttoreadtheseinstructions,andtofollowthem.
2.Keepthisinstructionmanualinanaccessibleplace.
3.Cleanonlywithadrycloth.Cleaninguidsmayaffectthehardware.
4.Referallservicingtoqualiedpersonnel.Servicingisrequiredwhenthe
apparatushasbeendamagedinanyway,suchasapowersupplycord
orplugisdamaged,liquidhasbeenspilledorobjectshavefallenonto
theapparatus,theapparatushasbeenexposedtoanyrainormoisture,
doesnotoperatenormallyorhasbeendropped.
5.
WARNING–Toreducetheriskofreorelectricshock,donot
exposethisapparatustorainormoisture.Theapparatusshallnotbe
exposedtodrippingorsplashingandnoobjectslledwithliquids,such
asvases,shallbeplacedontheapparatus.
TO PREVENT ELECTRIC SHOCK REFER
SERVICING TO QUALIFIED PERSONNEL
Ampetronic R1 Handbook Page 1
R1 Handbook

INTRODUCTION
TheLoopworksMeasureR1hasbeendesignedinconjunctionwiththe
LoopworksMeasureiOSAppasahighqualitypieceoftestequipmentfor
detectionandevaluationoftheperformanceofAudioFrequencyInductionLoop
Systems(AFILS)totheinternationalstandardIEC60118-4.
Itissimpletousewithalltypesofinstallation,fromsimpleservicepoint
applicationsthroughtolowspillareacoveragedesigns.Simplyholdthe
LoopworksMeasureR1inthesamepositionthehearingaidwillbeinoncethe
systemisoperational:i.e.holdtheunitatheadheighttotakemeasurements:
eitherseated,orstandingdependingonthevenue.
Aheadphonesocketisprovidedtoallowaudiblemonitoringandsubjective
testingofthesystem.DetailsofusearegivenintheHearingLooptestand
commissioningprocedure.
OVERVIEW OF UNIT
OPERATION OF UNIT
Method of use
1. DownloadLoopworksMeasureApptodevice
2. UnpackLoopworksMeasureR1
3. ConnecttotheiOSdevicerunningtheApp
4. Inserttheheadphonesintothesocketonthetopoftheunittomonitor
receivedsignal.Adjustthevolumeusingthecontrolsonthedevice
runningtheApp.
5. UseasbasicmeterorsignintoLoopworksMeasuretocapturetest
resultsandgeneratereports
Measure R1
www.ampetronic.com
Measure R1
www.ampetronic.com
Measure R1
www.ampetronic.com
Measure R1
www.ampetronic.com
3.5mm(1/8inch)
Jackplugfor
connectiontoiOS
devicerunning
App
3.5mm(1/8inch)
Headphone
socket
Top Bottom
Home Advanced
Background
Noise
Frequency
Response
Field
Strength
Test
PerimeterLoop
Unacceptable
-5.2 db
-22
0
+8
+2
1kHz/ 400 mA/m
+1
+3
+4
+5
+7
+6
-1
-2
-3
-4
-5
-12 -9
Instructions
FSM
MeasureR1
www.ampetronic.com
3030
3030
3030
3030
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.1
0
2.0
Standing = 1.7m
Seated = 1.2m
Listening Height (Meters)
0cm
100cm
50cm
150cm
200cm
170cm
0cm
-50cm
50cm
A
Distancefrom
counterprole
+Oset to loop
= 55cm
B
DE
Suggested
Oset
25cm
45˚
30cm
0cm
100cm
50cm
150cm
200cm
145cm
0cm
-50cm
50cm
B
Distancefrom
counterprole
+Oset to loop
= 55cm
0cm
100cm
50cm
150cm
200cm
120cm
0cm
-50cm
50cm
Distancefrom
counterprole
+Oset to loop
= 55cm
C
N.B.Formostapplicationsitisthe
verticalcomponentofthemagneticeld
thatisreceivedbythehearingaid,as
aresulttheLoopworksMeasureR1is
designedtobeusedwhileheldvertically
asshown:
Home Advanced
Background
Noise
Frequency
Response
Field
Strength
Test
PerimeterLoop
Unacceptable
-5.2 db
-22
0
+8
+2
1kHz/ 400 mA/m
+1
+3
+4
+5
+7
+6
-1
-2
-3
-4
-5
-12 -9
Instructions
FSM
MeasureR1
www.ampetronic.com
3030
3030
3030
3030
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.1
0
2.0
Standing = 1.7m
Seated = 1.2m
Listening Height (Meters)
0cm
100cm
50cm
150cm
200cm
170cm
0cm
-50cm
50cm
A
Distancefrom
counterprole
+Oset to loop
= 55cm
B
DE
Suggested
Oset
25cm
45˚
30cm
0cm
100cm
50cm
150cm
200cm
145cm
0cm
-50cm
50cm
B
Distancefrom
counterprole
+Oset to loop
= 55cm
0cm
100cm
50cm
150cm
200cm
120cm
0cm
-50cm
50cm
Distancefrom
counterprole
+Oset to loop
= 55cm
C
Ampetronic R1 HandbookPage 2

TROUBLESHOOTING
No Headphone signal
Checktheheadphonesarepluggedin,andthevolumecontrolisturnedup.
Low magnetic eld strength
Checktheloopsystemisrunningcurrent.
IfthereisinsufcientCURRENT,orexcessivemetalloss,theapplicationmay
requireaspecialloopdesigntoachieveacceptableperformance,contact
Ampetronicforadvice.
Background noise
Checkallloopsystemsareswitchedoffandnotrunninganycurrent.
Iftheinterferenceisstillpresentwiththeloopsystemswitchedoff,locateand
eliminatethesourceoftheinterferencebeforeswitchingtheloopsystemback
on.Monitorwithheadphoneswhilstswitchingotherelectricalsystemssuchas
power,lightingetcONandOFF
SPECIFICATIONS
PARAMETER VALUE
Magnetic eld measurement Coilorientation:Verticalwhenunitheldupright
Referencelevel:400mA/m(ineldstrengthmode)
Frequency response
50Hzto8kHz±0.25dB
40Hzto10kHz±0.5dB
30Hzto15kHz±0.3dB
Gainstability:Betterthan±0.25dBoverallconditions
Audio Inputs
3.5mm4-polejackplugforconnectiontoApple
iOSdevice
3.5mm3-polejacksocketformonitoringwithstereo
headphones
Calibration power <100mW
Measurement power <1mW
Dimensions 52.0x27.5x9.5mm
Weight 10g
Operating temp range -10to+45°C(Storage-20to+75°C)
TROUBLESHOOTING
DetailsofallproductsandservicesprovidedbyAmpetroniccanbefoundatour
website:www.ampetronic.com
Ampetronic R1 Handbook Page 3

Ampetronic R1 HandbookPage 4
WARRANTY & CALIBRATION
Thisproductcarriesaoneyearpartsandlabourwarrantyfromdateofshipment
fromAmpetronic.Thewarrantycouldbeinvalidatediftheinstructionsinthis
handbookarenotfollowedcorrectly,oriftheunitismisusedinanyway.
TheLoopworksMeasureR1iscalibratedduringmanufacturingtest,andis
validuntiloneyearfromthedatetheequipmentleavesAmpetronic.Calibration
reviewisrecommendedoneyearfromthisdate,howeverthisperiodmaybe
extendeddependingonuseandrequirements.
DECLARATION OF CONFORMITY
Manufacturer: AmpetronicLtd.Unit2,TrentsideBusinessVillage
FarndonRoadNewarkUnitedKingdomNG244XB
Declaresthattheproduct:
Description: FieldStrengthMeter
Typename: R1
ConformstothefollowingDirective(s)andNorm(s):
Directive2004/108/EC
EMC: EN55103-1:2009Emission
EN55103-2:2009Immunity
Directive: 2006/95/EC
Safety: EN60065:2002+A12:2011
Directive: 2011/65/EURoHS
Part15: ThisdevicecomplieswithPart15oftheFCC
Rules.Operationissubjecttothefollowingtwoconditions:(1)
thisdevicemaynotcauseharmfulinterference,and(2)this
devicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.”
Date:June2015,
J.R.Pieters,ManagingDirector,AmpetronicLtd.
Contactinformation
Website:www.ampetronic.com,Portal:loopworks.ampetronic.com
Technical:[email protected],Sales:[email protected]
Tel:+44(0)1636610062
Table of contents
Other Ampetronic Measuring Instrument manuals