1
English
TR300
Temperature and Relative
Humidity Data Logger
Users Manual
TR300_Rev001
© 2008 Amprobe Test Tools.
All rights reserved.

3
Sensor
2.5”X 2.0” LCD display
Speaker
Alarm LED
Record LED
Start/Stop to turn on and off
the unit
Mode
Set
Up scroll
Down scroll
9V DC adaptor (>= 500mA.
Depth:9mm Inner: 1.35mm.
Outer: 3.5mm) Not Included
USB adaptor (USB cable is
optional accessory)
Tripod mounting screw (tripod
not included)
Primary display: Displays the measured
temperature in °C or °F.
DP: Dew point indicator
REC: recording indicator
Low battery indicator
Secondary display: Displays the air
humidity
Date indicator
Time indicator
Date and time display: Alternates
between date and time display
DP
REC 20.8 °C
36.5 %
Y-M-D 08-02-13
1
2
5
3
4
6789
1 0
12
1 1
1 3
%
DP
REC
Y-M-D
H:M:S
2
3
4
5
6
7
1
8

4
TR300
Temperature and Relative Humidity Data Logger
CONTENTS
Introduction.........................................................................................................................................5
Unpacking and Inspection..................................................................................................................5
Operation ............................................................................................................................................5
Setting Mode .................................................................................................................................5
Sample point:.................................................................................................................................6
Start Mode: ....................................................................................................................................6
Start Time: ......................................................................................................................................7
Sample Rate ...................................................................................................................................8
Alarm Set........................................................................................................................................9
Real Time......................................................................................................................................10
Switch from °F to °C.....................................................................................................................10
Dew point measurement: DP......................................................................................................10
Instrument Connection.....................................................................................................................10
RS232 PC interface capabilities ...................................................................................................11
Download Suite Software installation .......................................................................................11
Operation.....................................................................................................................................11
Troubleshooting................................................................................................................................11
Specifications.....................................................................................................................................12

5
INTRODUCTION
The TR300 Temperature and humidity logger is well suitable to monitor indoor air quality. It
is designed with a wall-mounted hook in the back for easy installation. It has a very large LCD
display, an audible and visible alarm, and a quick response sensor to help monitor easily the
air temperature and humidity. It also has 16K memory capacity storage to record and save
continuous readings.
Please read this manual thoroughly before operation. You will find it very easy to operate and
a valuable instrument to measure & record the air temperature & humidity.
UNPACKING AND INSPECTION
The standard package of this product contains:
1 X TR300 meter
1 X Instruction Manual
1 X Download Suite CD
1 X USB Cable
4 X AA battery
OPERATION
Turn ON and OFF the unit
Press START/STOP pushbutton for less than 1 sec•
The display will show current temperature, humidity, the date and time in alternate fashion.•
Setting Mode (See Fig 4 for Symbols meaning)
Press SET pushbutton to enter the setting mode or use the software program .1.
Use Up and Down pushbuttons to select from:2.
Sample point: ‘PtS’ & ‘P1’ show on the display•
Start mode: Stn’ and ‘P2’ show on the screen•
Start Time: ‘Stt’ & ‘P3’ show on the display•
Sample rate: ‘Sr’ & ‘P4’ show on the screen•
Alarm set: ‘AL’ & ‘P5’ show on the screen•
Real time: ‘rtC’ & ‘P6’ shown on the display•

6
Sample point:
From ‘Pts’ & ‘P1’, press SET key•
Press up and Down pushbuttons to select the sample point from 1h(1000)…….16h(16000).•
The sample point will be divided in half: ½ for temperature and ½ for humidity. Example:
16000 points= 8000 Temp + 8000 RH
Press SET to save and return to P1•
Press MODE to escape without saving the value•
Start Mode:
Press Up and Down keys to select from:
Repeat: ‘rEp’ is displayed on the bottom of the screen. In this mode the meter will•
automatically record again once the memories are uploaded to a PC.
From ‘Stn’ & ‘P2’, press SET key
Press Up or Down key to select ‘rEp’
Press SET to save and return to P2
Press MODE to escape
Press Up and Down Press SET to save

7
Key Start: ‘hEy’ is displayed on the bottom of the screen. In this mode, the meter will start•
recording when you press Start/Stop for more than 2 seconds.
From ‘Stn’ & ‘P2’, press SET key
Press Up or Down key to select ‘hEy’
Press SET to save and return to P2
Press MODE to escape
Immediately: ‘|Nn’ is displayed on the bottom of the screen. In this mode, the meter will•
start recording immediately after you save the setting.
From ‘Stn’ & ‘P2’, press SET key
Press Up or Down key to select ‘|Nn’’
Press SET to save and return to P2
Press MODE to escape and start recording.
To stop the recording, press and hold Start/Stop for more than 2 seconds.
Schedule: ‘SCh’ is displayed on the bottom of the screen. In this mode, the meter will start•
recording from the preset date and time.
From ‘Stn’ & ‘P2’, press SET key
Press Up or Down key to select ‘SCh’’
Press SET to save and return to P2
Press MODE to escape
Start Time:
Press SET to enter the setting mode•
Press Up or Down key to select ‘Stt’ & ‘P3’•
Press SET to enter edit mode for year ‘YEr’•
Press Up or Down key to adjust the year•
Press SET to enter edit mode for month ‘Mon’•
Press Up or Down key to adjust the month•
Press SET to enter edit mode for day ‘dAt’•
Press Up or Down key to adjust the day•
Press SET again to enter the edit mode foe hour’Hor’•
Press Up or Down key to adjust the hour•
Press SET again to enter the edit mode of minute’NI n’•
Press Up or Down key to adjust the minute•
Press SET again to enter the edit mode for Second ‘Sec’•
Press Up or Down key to adjust the second•
Press SET to save the date and time•
Press MODE to quit•

8
Sample Rate
Press SET key to enter sample rate mode•
Press Up or Down key to select ‘Sr & P4’•
Press SET to enter edit mode for HOUR•
‘Hor’
Press Up or Down key to adjust the hour•
Press SET to enter edit mode for MINUTE•
‘N| n’
Press Up or Down key to adjust the•
minute
Press SET to enter edit mode for SECOND•
‘SEc’
Press Up or Down key to adjust the second•
Press SET to save and return to P4•
Press mode to quit and return to main menu•
Y-M-D
Y-M-D
Y-M-D
H:M:S
H:M:S
H:M:S

9
Alarm Set
Press SET key to enter the alarm setting•
Press Up or Down key to select ‘AL & P5’•
Press set key to edit HIGH temperature ‘tH’•
Press Up or Down key to adjust the high temperature•
Press set key to edit LOW temperature ‘tLo’•
Press Up or Down key to adjust the low temperature•
Press set key to edit HIGH humidity ‘HH’•
Press Up or Down key to adjust the high humidity•
Press set key to edit LOW humidity ‘HL’•
Press Up or Down key to adjust the low humidity•
Press SET to save and return to P5•
Press MODE to quit and return to main menu•

10
Real Time
Press SET to enter real time setting•
Press Up or Down key to select ‘rTC & P6”•
Press SET to edit YEAR ‘yEr’•
Press Up or Down key to adjust the year•
Press SET to edit MONTH ‘Non’•
Press Up or Down key to adjust the month•
Press SET to edit DAY ‘dAt’•
Press Up or Down key to adjust the day•
Press SET to edit HOUR ‘Hor’•
Press Up or Down key to adjust the hour•
Press SET to edit MINUTE ‘Mi n’•
Press Up or Down key to adjust the minute•
Press SET to edit SECOND ‘Sec’•
Press Up or Down key to adjust the second•
Press SET to save and return to P6•
Press MODE to quit and return to main menu•
Switch from °F to °C
Press and release MODE key to change from °F to °C•
Dew point measurement: DP
Press and hold MODE key for dew point reading•
Press and release MODE key to change DP from °F to °C•
Press and hold MODE key to return to temperature reading.•
INSTRUMENT CONNECTION
Plug the RS232 cable to the meter to turn it ON.1.
Connect the meter with the PC using the RS232 provided2.
Start the Download Suite software program3.
H:M:S

11
RS232 PC interface capabilities
The RS232 cable and the Download Suite software are required to transfer data to a PC. The
RS232 port is located on the right side of the instrument. There is an optional USB converter kit
(RS-USB) available for PCs with no available RS232 port.
Download Suite Software installation
Insert the Download Suite CD into the CD-ROM drive.
To install the software, follow the on-screen instructions.
Operation
Open the program, double-click the Download Suite icon.1.
Click on work “with instrument” and then “next”2.
Select TR300 and click on “next”3.
Select Program device and click on NEXT . Click on NEXT again to open the programming4.
screen (see Figs 1&2)
Setup the parameters and click OK to start recording5.
To download file from the device, repeat steps 1 and 2. Select Download and click NEXT.6.
(See Fig.1)
Click NEXT again to start downloading the file. Select the location where you want to store7.
the file and click NEXT, YES or NO, and FINISH
Click on “Visualizations” to select digital meter, generic historical graph, or generic historical8.
table.(See Fig.3)
Select the parameters you want to visualize and click OK.9.
NB. Refer to help menu for more details on how to use the Download Suite.
TROUBLESHOOTING
Power on but no display or meter doesn’t work .
Check whether the DC power is connected or not.•
Make sure you press ”START/STOP” key for more than 0.1 Sec.•
Check the batteries and see if they make good contact and the polarity is correct.•
Replace the batteries and try again.•
Error Codes.
E02: The value is underflow.•
E03: The value is overflow.•
E04: Wrong value is caused by E02 or E03.•
E11: RH calibration error. Need to re-calibrate.•
E32: IC read/write error. Return the meter for repair.•
E33:Circuit error in measurement portion. Return the meter for repair.•

12
SPECIFICATIONS
Mode Range
RH % 0.0 ~ 100.0%
Resolution 0.1%
Accuracy +/-3% @ 10~90%;+/-5% @ others
Temperature -20°C to 70°C (-4°F to 158°F)
Resolution 0.1°C (0.1°F)
Accuracy ±0.6°C (±1°F) @ 0–50°C (32–122°F); ±1.2°C (±2°F) @ others
Memory Up to 16K (Temp: 8K + RH: 8K)
Real Time Yes
USB Port Yes

13
Figure 2
Figure 1
Supporting Figure Diagrams

14
DISPLA Y ALPHABET LIST
A
d
H
k
m
o
r
t
C
E
i
L
n
P
S
y
Display DisplayMeaningMeaning
Figure 3
Figure 4
Other manuals for TR300
1
Table of contents
Other Amprobe Data Logger manuals
Popular Data Logger manuals by other brands

SENSECAP
SENSECAP S2100 user guide

National Instruments
National Instruments PCI-7811 user manual

Goodwe
Goodwe EzLogger Pro SERIES user manual

Grant Datalogging
Grant Datalogging Squirrel 2040 Series quick start

Monarch
Monarch Track-It 5396-0321 manual

ATI Technologies
ATI Technologies DLX 1100 Series quick start guide