Ampronix AMVX2408 User manual

AUTO - SCANNING WITH DIGITAL CONTROL
LCD COLOR MEDICAL MONITOR
AMVX2408
OperationManual
Forfuturereference, recordtheserial numberofyour display
monitorin thespace below:
SerialNumber
Theserial numberis locatedon theback ofthe monitor


backof themonitor
Ampronix 2007
Allothertrademarksarethepropertyoftheirreferenceowners.
This document is subject to change without notice.
Ampronixprovidesthisinformationasreferenceonly.Referencetoothervendor’s
productsdoesnotimplyanyrecommendation or endorsement.
Revision Control
GNINRAW
elbissopfosresuehtmrofniotdesusi"GNINRAW"eltitehT egamadytreporpro,htaed,yrujniehttcilfnidluoct
ahtsesuac .stneitapehtot
NOITUAC
elbissopfosresuehtmrofniotdesusi"NOITUAC"eltitehT tonthgimtihguohtlastneitapehttcilfnidluoctaht
sesuac .shtaedesuacothguoneereves
ETON
eratahtsmetifosresuehtmrofniotdesusi"ETON"eltitehT ro,noitarepo,noitallatsnifosmretniecnatropmifo t
onseoderuliafehthguohtlatnempiuqEehtfoecnanetniam .stneitapehtotmrahylidobehttcilfni
etaDnoitpircseD
70712120.VERrebmuntnemucoD
AMVX2408 1

TABLE OF CONTENTS
ProductDescriptionandIntendedUse......................................................
WarningsandCautions................................................................................
SymbolExplanations....................................................................................
EUDeclarationofConformityforMedicalApplications...........................
SafetyPrecaution.........................................................................................
CleaningYourMonitor..................................................................................
PowerManagementFunction....................................................................
PresetModes..............................................................................................
VideoSignals..............................................................................................
PIP/POP/PBPfunction...........................................................................
DDC.............................................................................................................
Installation....................................................................................................
ConnectingthePowerCord......................................................................
UserFunction/Messages.........................................................................
OSDSection...............................................................................................
Troubleshooting..........................................................................................
Specificationof(AMVX2408)..................................................................
Classification..............................................................................................
ElectromagneticCompatibility..................................................................
DimensionDrawing(mm)..........................................................................
Connectors..................................................................................................
3
4
7
8
9
9
10
11
12
13
14
14
15
16
17
24
25
26
27
30
31
2User’s Guide

Product Description and Intended Use
Please check the following items are present when you unpack the box, and save the
packing materials in case you will need to ship or transport the monitor in future.
•AMVX2408LCDMonitorandtwovideocables(1)HD15 VGA cable* (1) DVI-D
cable*
•ACPower cord**
•AC-Adapter
•CompositeVideoBNCJackCableandSuperVideoCable
•User Manual and 4pcs VESA screws
*Might be optional item, check with local representative
**Might vary pending on region stardard
CAUTION
Manufacturer: JEC Korea
Model No :
JMW1150KA2400F04
**
AMVX2408 3

Warnings and Cautions
Please read this manual and follow its instructions carefully. The words warning,
caution,and note carry special meaningsand should be carefully reviewed:
Warranty is void if any of these warnings are disregarded.
Ampronix accepts full responsibility for the effects on safety, reliability, and
performanceoftheequipment only if:
•Re-adjustments, modifications, and/or repairs are carried out exclusively
by Ampronix.
• The electrical installation of the relevant operating room complies with the
applicable IEC and CE requirements.
Warning Federal law (United States of America) restricts this
device to use by, or on order of a physician.
TheAmpronixAMVX2408monitorhasbeen tested under UL60601-1 standardand
ULlisted for Medical application.
Ampronixreserves the right to makeimprovements in the product(s) described
herein. Product(s), therefore, may not agree in detail to the published design or
specifications.All specifications are subject to change without notice. Please
contactAmpronixdirectly or phone yourlocalAmpronix salesrepresentative or agent
forinformationon changes and new products.
ebyamnaicisyhprotneitapehtfoytefaslanosrepehTgninraW nitluserdluocnoitamrofnisihtgnidragersiD.devlovni .naicisyhprotneitapehtotyrujni
ebtsumsnoituacerproserudecorpecivreslaicepSnoituaC .tnemurtsniehtgnigama
ddiovaotdewollof
etoN tnatropmiroreisaeecnanetniamekamotnoitamrofnilaicepS .raelceromnoitamrofni
ehttrela
otdednetnisielgnairtanihtiwkramnoitamalcxenA ecnanetniamdnagnitarepotnatropmifoecneserpehtotresu .tcudorpehtgniynapmoccaerutaretilehtnisnoitcurtsni
ehtfonrawotdednetnisielgnairtanihtiwtlobgninthgilA deziroh
tuaotecivresllarefeR.egatlovsuodrazahfoecneserp .lennosrep
RESUEHTOTYRUJNISUOIRESLAITNETOPDIOVAOTgninra
W,ECIVEDSIHTOTEGAMADRO/DNATNEITAPEHTDNA :TSUMRESUEHT
4User’s Guide

Warnings
1. Read the operating manual thoroughly and be familiar with its contents prior to using
this equipment.
2. Carefully unpack the unit and check if any damage occurred during shipment.
3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked
by qualified personnel before operating it any further.
4. Uplug the unit if it is not to be used for an extended period of time. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
5. Be a qualified physician, having complete knowledge of the use of this equipment.
6. Test this equipment prior to a medical procedure. This monitor was fully tested at the
factory before shipment.
7. Avoid removing covers on control unit to avoid electric shock.
8. Attempt no internal repairs or adjustments not specifically detailed in this operating
manual.
9. Pay close attention to the care, cleaning instructions in this manual. A deviation may
cause damage (refer to the Cleaning section).
10. DO NOT STERILIZE MONITOR.
11. Read the entire instruction manual before assembling or connecting the camera.
12. Do not place the monitor or any other heavy object on the power cord. Damage to the
cable can cause fire or electirc shock.
13. Monitor with power supply is suitable for use in patient environment.
14. DO NOT stack more than 8 boxes high
This equipment has been tested and found to comply with the limits for medical devices
in IEC 601-1-2:2003. These limits are designed to provide reasonable protection against
harmful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
other devices in the vicinity. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to other
devices, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment into an outlet on a circuit different from that to which the other
device(s) are connected.
- Consult the manufacturer or field service technician for help.
NOTICES TO USER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCCWARNING
This equipement generates or uses radio frequency energy. Changes or modifications not
expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment. The user could lose the authority to operate this equipment if an
unauthorized change or modification is made.
AMVX2408 5

Cautions
1. The AC Adapter must be plugged into a Grounded power outlet.
2. Use only the proprietary AMVX2408 power supply for the AMVX2408 monitor.
Make a proper connection by ensuring that the shrink tubing completely secures the
connection between the DC power cord and the extension cord.
3. Turn power off when unit is not in use.
4. Never operate the unit right after having transported from a cold location directly to a
warm location.
5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the
screen. Spray the cleaning solution into a soft cloth and clean gently.
6. Handle the monitor with care. Do not strike or scratch the screen.
7. Do not block the monitor cooling vents. The monitor is cooled by natural convection
and has no fan.
8. Do not force the monitor past 28 degrees of vertical when adjusting the screen
position. (For monitors equipped with stands only.)
9. Remove the power module and connection when transporting the unit.
10. Save the original carton and associated packing material. They will be useful should
you have to transport or ship the unit.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,
draperies) that may block the ventilation slots.
13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
14. The unit is designed for operation in a horizontal position. Never operate the unit in
a vertical position.
15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)
16. Do not expose the monitor to moisture or excessive dust.
17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or
IEC 60601-1-1 harmonized national standard or the combination should be evaluated.
Do not touch the patient with signal input or output connectors.
18. Use only a hospital grade power supply cord.
19. This equipment has been tested and found to comply with the limit for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide resonable generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation, which can be detemined by turing the
equipment off and on, the user is encourage to try to correct the interference by one
or more of the following measures:
• Reorient or relocate the receiving device.
• Increase the separation distance between the equipment.
• Connect the equipment to an outlet on a circuit different from that to which the
other device(s) are connected.
• Consult the manufacturer or field service technican for help.
20. Grounding reliability can only be achieved when the equipment is connected to an
equipment receptacle labeled “Hospital Only” or “Hospital Grade.”
Note To connect to an international power supply, use a an attachment plug
appropriate for the power outlet.
Note Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to
ensure EMC. The AMVX2408 must be installed and operated according to the
EMC information provided in this manual.
6User’s Guide

Symbol Definitions AMVX2408 7

EU Declaration of Conformity for MedicalApplications
ADeclarationof Conformity has been filedfor thisproduct.Asampleof
thisdocumentmay befound in theaddendum whichaccompaniedthis
manual. Fora copy of the Declarationof Conformitydocument, please
contactAmpronixand request forAMVX2408 DOC.
Prepare for Unpack
Beforeyou unpackyour monitor, preparea suitableworkspace.You
needa stable and level surfacenear agrounded walloutlet inan area
whichisrelatively freeof glare fromsunlight orother sources ofbright
light.Themonitor is cooledby natural convection(ithas nofan).
Foroptimum performance, donot blockthe cooling vents.
Whileunpackingthe monitor,inspect it and otherpackage contentsfor
shippingdamage that could cause afire orshock hazard.Immediately
reportany shipping damage to thecarrier ortransportation company
andcontact customer service for monitorin thefuture orin caseof
return.
Afteryouunpackthe monitor,make surethefollowing itemsare in-
cluded
• Monitor with video cable
• AC adapter with cable
CAUTION:ACAdaptermustbe plugged into Grounded apower outlet
CAUTION :AC adapter
Manufacturer: JEC korea
Model No: JMW1150KA2400F04
• This operations manual
Note: Your system provider may offer alternative cords or cables
dependingonthe installationrequirementand localgeography issues.
8User’s Guide

SAFETY PRECAUTION
· Avoid placing the monitor, or any other heavy object, on the power cord to prevent
fire or electrical shock from damage to the power cord.
· Donot expose the monitor torain,excessivemoisture, or dust to avoidfireorshock
hazard.
· Donot cover theslotsoropeningsofthe monitor forproperheatdissipation.Always
putthemonitor in a place where there is adequate ventilation.
· Avoid placing the monitor against a bright background or where sunlight or other
light sources may reflect on the area of the monitor. Place the monitor just below
eyelevel.
· Handlewith care when transporting the monitor.
· Refrain from giving the shock or scratch to the screen, as screen is fragile.
CLEANING YOUR MONITOR
No specific liquid or chemical necessary when cleaning this LCD monitor
However,we suggest to clean the monitor withnon-abrasivecloths and cleaning
solutions used in hospitals to clean similar equipment. We recommend using 70%
Isopropylalcohol for the screen surface and warm water anda mild detergent for all
othersurfaces. Other acceptable cleaningagents are listed below:
• 70% isopropyl alcohol
• Cidex (2.4% glutaraldehyde solution)
• 0.5% Chlorhexidine in 70% isopropyl alcohol
To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away
Form the monitor and spray cleaning solution onto a cloth. Without applying exces-
sivepressure, clean the screenwith the slightly dampened rag.
AMVX2408 9

POWER MANAGEMENT FUNCTION
Themonitorisequippedwiththepowermanagementfunctionwhichautomaticallyreduce
thepowerconsumptionwhennotin use in three power level modes.
•Stand-by Mode
The monitor goes into stand-by mode when the horizontal sync signal is off for
about10 seconds. In this mode, the screengoesoffandthepower LED blinks for 1
seconds On and 1 second Off. The screen is displayed after the horizontal sync
signal is restored.
•Suspend Mode
The monitor goes into suspend mode when the vertical sync signal is off for about
10seconds.The power consumption during this is less than8W.In this mode, the
screengoesoffandthe power LED blinks for 1 seconds On and 1 second Off.The
screen is displayed after the vertical sync signal is restored.
•Off Mode
Themonitor goesintopower-offmode whentheverticaland horizontalsyncsignals
are off for about 10 seconds. In this mode, the screen goes off and the power LED
blinksfor 1 seconds On and 1 second Off. The screen isdisplayedafterthevertical
and horizontal sync signals are restored.
Power Management System
TheAMVX2408MedicalMonitorpower management proposal. Provides fourphases
of power-saving modes by detecting the horizontal sync signal as shown in the table
below.
When the monitor is power saving mode or detects an incorrect timing, the screen will
be blank and power LED indicator will blink.
10 User’s Guide
27W27W27W97WPower
Consumption
Red Flashing
(1 sec.
Interval)
Red Flashing
(1 sec. Interval)
Red Flashing
(1 sec. Interval)
GreenPower Indicator
BlankedBlankedBlankedActiveVideo
InactiveInactiveActiveActiveVertical Sync
InactiveActiveInactiveActiveHorizontal Sync
DPMS OffDPMS suspendDPMS StandbyNormal
Operation
State
27W27W27W97WPower
Consumption
Red Flashing
(1 sec.
Interval)
Red Flashing
(1 sec. Interval)
Red Flashing
(1 sec. Interval)
GreenPower Indicator
BlankedBlankedBlankedActiveVideo
InactiveInactiveActiveActiveVertical Sync
InactiveActiveInactiveActiveHorizontal Sync
DPMS OffDPMS suspendDPMS StandbyNormal
Operation
State

PRESET MODES AMVX2408 11
noituloseRlatnoziroH ycneuqerf )zHK(
lacitreV ycneuqerf )zH(
kcolclexiP )zHM(
zH06@053x046964.13149.95571.52
zH07@
053x046964.13780.07571.52
zH58@053x04668.73080.58005.13
zH06@004x046964.13149.95571.52
zH07@004x046964.13780.07571.5
2
zH58@004x04668.73080.58005.13
zH06@084x046964.13049.95571.52
zH27@084x046168.73908.27005.13
zH57@084x046005.73000.
57005.13
zH58@084x046962.34800.58000.63
zH58@004x027729.73830.58005.53
zH65@006x008651.53052.65000.63
zH06@006x00897
8.73713.06000.04
zH27@006x008770.84881.27000.05
zH57@006x008578.64000.57005.94
zH58@006x008476.35160.58052.65
zH34@8
67x4201225.53859.68009.44
zH06@867x4201363.84400.06000.56
zH07@867x4201674.65960.07000.57
zH57@867x4201320.06920.570
57.87
zH58@867x4201776.86799.48005.49
zH06@468x2511843.45350.06000.08
zH07@468x2511559.36610.07002.49
zH57@468x251
1005.76000.57000.801
zH06@069x0821000.06000.06000.801
zH58@069x0821839.58200.58005.841
zH06@4201x0821479.36310.06005
.801
zH57@4201x0821679.97520.57000.531
zH58@4201x0821641.19420.58005.751
zH06@0021x0061000.57000.06000.261
zH06@00
21x0291990.47999.95521.451

Video Signals
12 User’s Guide
tamroFoediV-CoediV-S1IDS2IDS BGR/tnenopmoC
rP/bP/YBGR
CSTNOO
LAPOO
i49.95/084 OOO O
p49.95/084OO
i05/675 OOO O
p05/675OO
p05/027 OOO
p49.95/
027 OOO O
p06/027 OOO O
i49.95/5301 OOO O
i06/5301 OOO O
fsp89.32/0801 OOO
fsp42/0801 OOO
p89.32/0801 OOO
p42/0801 OOO
p52/0801 OOO
p79.92/0801 OOO
p03/0801 OOO
i05
/0801 OOO O
p05/0801O
i49.95/0801 OOO O
p49.95/0801O
i06/0801 OOO O
p06/0801O

AMVX2408 13
PIP / POP / PBP function
Thefollowing combination options are available toyou:
PIPniaMAGVIVD1IDS2IDSoediV-CoediV-StnenopmoC
AGV OOOOOO O
IVD OOOOOO O
1IDS OOO OO O
2IDS OO OOO O
oediV-C OOOOOO O
oediV-S OOOOOO O
tnenopmoC OOOOOO O

DDC
To make your installation easier, the monitor is able to Plug and Play with your system
if your system also supports DDC protocol. The DDC (Display Data Channel) is a
communicationprotocolthrough whichthe monitorautomaticallyinformsthehostsystem
aboutits capabilities,forexample,supported resolutionsandcorrespondingtiming. The
monitorsupports DDC1 and DDC2Bstandard.
INSTALLATION
To install the monitor to your host system, please follow the steps as given below:
Steps
1. Usethe supplied video cable (DVI, VGA, S-Video, C-Video) then connect tothehost
system accordingly.
2. ConnecttheDCpower to the DC power connector on the monitor.
3. Connectone endofACpowercord intotheACAdapterandtheotherend toACpower
outlet.
4. Then turn the host system on and then the monitor.
5. Ifthe monitorstilldoesnot function properly, pleaserefertothe troubleshooting
sectionto diagnose the problem.
14 User’s Guide
DVI VGA SDI INS - Video
C - VideoDC Power
IN
OUT
RGB / Component SDI OUT

CONNECTING the POWER CORD
* Check first to make sure that the power cord you use is the correct type required for
yourarea.
* Thismonitor has an universalACadapterthat allows operation in either
AC 100 - 240 V ac voltage area. No user-adjustment is required.
* Plug one end of the power cord to theAC adapter, plug another end to a proper
AC outlet.
The cord set should have the appropriate safety approvals for the country in which the
equipmentwillbeinstalled and marked HAR.
For 120 volt Applications, use only UL Listed deachable power cord with NEMA
configuration 5-15P type (parallel blades) plug cap. For 240 volt applications use only
ULListed Detachable power supply cord with NEMA configuration 6-15P type (tandem
blades)plugcap.
AMVX2408 15
Hospital-grade
power cord
Power Supply
Manufacturer: JEC Korea
Model No: JMW1150KA2400F04
Extension power cord (optional)
Manfacturer: JEC Korea
Model No: 1501047 (15ft) or
1501047001 (75ft)
AMVX2408

16 User’s Guide
User Functions / Messages
Key Name and Function
Power LED : Lights up to indicate the power is turned ON.
Power Switch :To power ON or OFF the monitor.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Ture Right) parameter or moves rightward in OSD menu.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Ture Left) parameter or moves leftward in OSD menu.
PIPSwitch : To enable or disable Picture In Picture function.
PBP Switch : To enable or disable Picture By Picture function.
POP Switch : To enable or disable Picture On Picture function.
Adjust Switch : To activate or deactivate image adjustment in sub screen of PIP,
PBP, POP mode.
Locker Switch : To turn ON or OFF the system.
How to access the menu
1. Push the “Knob” button to activate the OSD menu.
2.Able to turn left or right the button to select those icons. The icon will be
highlighted when is selected.
3. Push the “knob” button to go into the another OSD menu.
4. Turn left or right “Knob” button to increase or decrease the number of selected
function.
5. In order to exit from the OSD menu in a different layer, then choose the “Exit
option”. In case of long pushing and holding the button around two or three
seconds, then it will completely out from the menu regardless wherever you are.
6. Turn the “Knob” button in a fast way to the left or right, while the menu is not
activated, then input signal menu will turns up with “V” mark which is chosen
current available input signal. You can switch to another input signal source by
turning the knob slowly then select the target source by pushing the knob.

AMVX2408 17
OSD Section
Chromatic Adjust Color Temp, Gamma
Visual Adjust Brightness, Contrast, Phase, Chroma,
Sharpness-H, Sharpness-V
Setting Adjust Scale Mode, Mirror, Freeze Frame, Zoom / Pan,
PIP / POP, PBP
Advanced Adjust OSD Position Control, Screen Control, DPMS, Auto
Source Select, Smart Select, Restore Factory, Key Lock
Information Adjust Custom Entry, SN, Run Time, Input Format
Main Menu

18 User’s Guide
OSD Section
Chromatic
Color Temp Change the color temperature - D65, D93, S1, S2, S3, S4
Gamma Change the gamma value - 1.8, 1.9, 2.0, 2.1, 2.1S, 2.2, 2.3,
2.4, 2.4S, S0, Radio graph
Exit Exit the menu
Visual
Brightness Adjust the brightness of panel (Range 0 - 100)
Contrast Adjust the contrast of video (Range 0 - 100)
Phase Adjust the phase of video (Range 0 - 100)
*available for C and S - video
Chroma Adjust the chroma of video (Range 0 - 100)
*available for C and S - video
Sharpness-H Set the sharpness of horizontal image (Range 0 - 100)
Sharpness-V Set the sharpness of vertical image (Range 0 - 100)
Exit Exit the menu
Table of contents