AMTAST AMT-316 User manual

1
Mutil Function Distance Meter
Model : AMT-316
Operation Manual
Mutil Function Distance Meter With Laser
AM:T-316 multi fimction distance meter detennines the distance to the object through
electronic signals quickly and effective, the tool can display the result on the tow-row LCD with
back light. The tool with built-in computer chip has the ftmction of key indication and memory. It
can be used in continuous accumulative measurement, automatic areas
and
vohulle counting and
is an ideal tool for building and decoration industries (for example, land agent, upholstery
designer
and craftsman, etc.)
The tool has the ftmction of laser orientation,
it
will send out a line of highlighted red laser
beam to make you aim at the object easily when using. The automatic temperature compensation
fimction of the
tool can make the measwing result more accurately, and
at the same time show the
current enviIomnent temperatme precisely.
AMT-316 distance meer is the Class II laser tool
confonning to
IEC285
intern ational saf ety rule.
SAFETY INSTRUCTIONS
Failure to follow the inst:ructions listed below may cause
personal inj iury.
Read and understand all instructions prior to any operation.
Do not remove any labels from the tool.
Do not operate the tool with the presence of tlanunable/explosive gases.
Do not operate the laser tool around the children or allow children to operate the laser tool.
failure to do so will injure eyes of children.
Do not stare into the laser beam.
Do not project the laser beam directly into the eyes of others.
Do not set up the tool at eye level or operate the tool the laser beam by using optical tools
such as on or near a reflective surface, as the laser beam could be projected into your eyes or
the eyes of others.
Do not obseIVe binoculars and magnifying glass.
Remove the battery when storing the tool for an extended period of time in case of the

2
deterioration of battery and its damage to the tooL
Warning
DANGER
Class II Laser Product
Maximum Power Output< ImW
Wavelength: 630-660run
Do not stare Into beam!
Avoid direct eye exposure!
This tool emits a laser radiation!
TOOL COMPONENTS
A. Ultrasonic sensor
aperture
B. Laser pointer
C. Two row LCD with back light---the data of upper line is the
cur rent
measuring result, and the
data of lower line is the memory/computing result
D.
Mem ory input
key: Input the length, area
or
volwne into
mem ory
E. READ--- On/read key: Press this key to start the
tool and read the measured distance,
keep pressing
this key and move the tool to read values
dynamically.
F.
SET ---Clear! Menu: press this key to clear or
return back to the menu to select length,
area or vohune mode.
G. ---Memory read key: Read out and display the
value of length, area or volum e that are stored in
the
last time.
H. --Addition key: Add the measured length, area or volume
I. level vials
J.
Measuring reference---distance measurement is
counted from end of the tool .
ILUSTRATION OF DISPLAY SCREEN
A.Plus
B. Area/volume (L=length; W=with; H=height)
C. Memory
D. Memory, computing result
E. Current
measuring
result
F. Display when lack of electric quantity
G. Square foot
H. Cubic foot
I. Square meter
J. Cubic meter

3
OPERATION GUIDE
Battery installation
Open the battery compartment door on the back of the tool. and plug one 9 Volt block battery
onto the battery
COlUlector
and put the battery back to the
compartment and close the dOOf.
Distance measurement
Make the induction hole of the tool face against the
measured object (c.g the wall) and
keep the tool
vertical to the measured object; make sure the
poinl:
of the level vial stands
between the two line of the level vial by adjusting the position of the mstrwnent.
Press the READ key to start the tool, the instnunent is ready to work.
Press the READ key again to get the measured distance and the laser beam indicates the
measured
surf ace.
Keep pressing the READ key and move the tool to get the dynamical readings, and the
measured distance will be, displayed on upper portion of the screen;
Press the SET key and the READ key together to select the measuring unit as British
measmement or metric system. (original measuring unit : Metric measurement ).
Tips:
A.The measured object must be·nonnatively hard swface and not be blocked by any baniers;
B. Select a smooth hard surface with big area to measure for precise result;
C. If the measured surface is too small and iITegular or with soft mrface, chipboard can be
UBed on the surface of the measured object;
D. The tool cannot: measure through glasses;
E. The tool should be over 2 feet (60cm) away from the measured object when measuring;
F. To make sure accurate measmement, you should operate when temperature of the unit is
same with temperature of the circmnstance.
G. The distarice measurement should be counted from the end of the tool.
Addition (W/O using M memory)
Press key for measurement and the measmed value is displayed on upper portion of the
Press READ key to enter the addition mode, and the
"+"
icon will appear on the display and at
the same time, the result is displayed on the lower side of the display (press key again to cancel
the add operation);
Press
READ
key again for second time measurement, the measured value is displayed on upper
portion
of the
screen;

4
Press
E3
key again to display the stun on the lower portion of the screen;
• Repeat the steps above can continue accumulation.
Addition (using M memory)
Press the M key to save the fust: measured result,
and the "M+" will appear on the display,
Press the
READ
key for new measurement;
Press the key to enter th e addition mode , and
the "+" will appear on the display.
Press the RM key to recall previous measurement
for the addition (displayed on the bottom of the
display). and at the same time, the "M+" icon
disappears and the stored memories will be
automatically eliminated;
Press +/=key, the sum is shown on the lower portion of the screen.
Area
Press SET key to enter area mode, and the will appear on the display for calculation of a room
area;
The length character "L" on the display will blink showing the length measurement you will be
firstly taking. Press READ key to take length measurement that is displayed on upper portion of
the screen. (Step 1);
The width character "W" on the display will blink showing the next measurement to take.
Press READ key to take width measurement that is displayed on upper portion of the screen
(Step 2);
Then the area is automatically displayed on the lower portion of the screen;
Press the READ key again will toggle back and forth between the length and width
measurement on the upper portion of the screen;

5
Press SET key to clear the data on the portion of the screen, then can begin the new
calculation of area.
To choose measurement mode, press SET key again;
Tips:
Press the SET key one by one will toggle back and forth between the length. area and volwne
measurement. If there are daturn on the display, first pressing the SET key will clear the current
datum, and the mode Will be invariable.
Addition of area under area ode:
Press the M key to save the calculated area of first time measurement, at the same time, the
"M+" icon appears on the screen;
Press 00 key to clear the current displayed data, then can begin the second time
measurement and computation (follow step 1 and step 2 under the area section).
After getting the desired area of the second time computation, press +/= to enter the addition
mode. A
"+"
icon would appear on LCD.
Press RM key to recall the first calctllated area for the addition. The "M+" icon will disappear
and the stored memory will be automatically cleared;
Press
&3
key, the
S1UJl
of both areas is shown on the lower portion of the screen;
Repeal the slape above to keep adding the measured
Volume
Press SET key to enler volwne mode, and the will appear on the display for calculation of a
The length character "L" on the screen will blink showing length measurement will be taking.
Press READ key to take length measurement, the remIt will be displayed on upper portion of
screen.
(Step
I)
The width character "W" on the screen will blink showing the next
measureme nt
to take. Press
READ key to take width measurement, the· result will be
displayed on upper portion of screen. (Step
2);

6
The height character "H" on the screen will blink
showing the next measurement to take. Press
READ
key to take heipt measurement, the result will be displayed on upper portion of screen.
(Step 3);
Then the volume is automatically displayed on the
lower portion of the screen;
Pressing the
READ
key again will toggle back and forth between the length, width and height
measuremem on the upper portion of the screen;
Press SET key to clear the data on the portion of the
screen, and then can begin the new
calculation of
volume ;
To choose measurement mode, press SET key again.
Tips:
Press the SET ke y one
by
one will toggle back and
forth between the length, area, volume and
length
measurement. If there are datum on the display, first
pressing the SET key will clear the CllITelll
datum,
and the mode will be invariable .
Addition of volumes under volume mode:
Press M key to save the calculated volume of first time measurement, and the "M+" icon will
appear
on
LCD;
Press SET key to clear the current displayed data, then can begin the second time
measurement and computation (Follow step 1 to 3 under the volume section).
After getting the calculated volwne of second time, press key to enter the addition mode. A
"+"
icon would appear on LCD;
Press RM key to recall the first calculated volume for the addition. The "M+" icon will
disappear and the stored memory will be automatically cleared;
Press =/+key, the awn of both volumes is shown on the lower portion of the screen.;
Repeat the steps above to keep adding the measured volume.
Temperature display
Press and hold SET key and at the same time press the RM key, the envirorunent temperature
will appear on the lower portion of screen (the unit is oC if the distance unit is M, while the unit is
oF if the distance unit is ft/in), and press the READ key again to return the measuring state.

7
OPERATION I NSTRUCTION
Inaccurate measurement may result
from
the following:
When the battery JUDS out: at this time, the icon
will
continuously appear on LCD to remind
you to replace the battery .
When the measmed distance is out of the specified range: the effective range is 2'~53' (0.6-
~16m).
When the calculated remit is out of the specified range: at this time. an error message "Err"
will be displayed on the lower line ofthe screen.
When addition of different parameters (e.g. length plus area), the
"+"
will be ignored and the
screen will keep the same read as the unit was operated
before.
When another ultrasonic source or high
frequency
noise is nearby: leave or shut down the
noise
resource when taking measurement.
When bani.ers appear between the tool and the
measured surface.
When the measured surface is not smooth: the measured surface should be smooth, hard
and of homogeneity.
When the measuring enviromnent is not good: the temperature and humidity will affect the
accuracy of measurement, and take measurement Wl.der enviromnent of no wind, and
temperature of the unit should be same 'With temperature of the circlDllStance, especially for
long distance measuring (between 40' to 53'/ 12m to 16m), the relative humidity should be above
480/0, and the size of measured surface should be at least 10ft. by 10ft/.3m by 3m.
When measuring. ultrasonic sensor aperture should straightly face to the measured surface.
Cautions
Handle with care and do not let the tool dr!'P
down.
Do not disassemble the tool to avoid failure.
Keep the tool dry and clean
Store the tool in the case when not in use.
Avoid dnsl and water, which may stain the lens.
Check battery regularly in case of its deterioration.
Remove the battery when not in use for an extended period of time.
WARRANTY
The product is warranted to be free from defects in materials and workmanship for a period of
one year from the date of purchase.

8
Notice:
The warranty does not apply to the following conditions.
Disassembling the laser tool will void the warnmty.
Any damage resulting from. but not limited to wear, water, being dropped or repairs
attempted by others.
Table of contents
Other AMTAST Measuring Instrument manuals