Ancona Brezza Manual

®
Brezzabathroom
fan with adaptor
User Manual
&
Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS
Carefully read the important information regarding
installation, safety and maintenance.
Keep these instructions for future reference.
MAAN4807-01
22-09-2017

Safety Information
WARNING — TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected
circuit. Do not use unapproved fans over a bathtub or shower that is not approved for that
application.
Installation work must be carried out by a qualied person(s) in accordance with all local and safety
codes including the rules for re-rated construction.
Always vent fans to the exterior and in compliance with local codes.
Install ductwork in a straight line with minimal bends.
Use 120 V, 60 Hz for the electrical supply and properly ground the unit. Follow all local safety and
electrical codes.
Do not use this fan with any solid-state control device; such as a dimmer switch. Solid-state
controls may cause harmonic distortion, which can cause a motor humming noise.
To reduce the risk of re or electric shock, do not block air entry grill.
Sufcient air is needed for proper combustion and exhausting of gases through the ute (chimney)
of fuel burning equipment to prevent back drafting.
Ducted fans must always be vented to the outdoors.
Mount with the lowest moving parts at least 2.5 meters above oor or grade level.
To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed
Control Device.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
Follow the heating equipment manufacturer's guideline and safety standards such as those published
by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air conditioning Engineers (ASHRAE), and the local code authorities.
WARNING Not suitable for use as a range hood.
— 2 —
CAUTION For general ventilating use only.
Do not use to exhaust hazardous or
explosive materials and vapors.
CAUTION Do not install in locations where the
air temperature will exceed 104°F (40°C).
IMPORTANT Exercise care to not damage
existing wiring when cutting or drilling into walls
or ceilings.
NOTE Make sure duct work size is a minimum
of the discharge. Do not reduce. Reducing the
duct size can increase fan noise.
IMPORTANT You may want to consult with
a professional electrician regarding the wiring
of your ventilation fan.
WARNING To reduce the risk of electric
shock, please disconnect the electrical supply
circuit to the fan before installing light kit.
CAUTION This product must be properly
grounded.

Pre-Installation
PLANNING FOR SUCCESSFUL INSTALLATION
When installing the ventilation fan in a new construction site, install the main body of the fan and duct
work during the rough-in construction of the building. The grill should be installed after the nished
ceiling is in place.
When installing in existing construction, use the dimensions on page 9 to determine the required hole
size for the ceiling. Grill edges should overlap nished ceiling.
Not for use in cooking area - see installation
instructions.
— 3 —
IMPORTANT The ducting from this fan to the outside of the building has a strong effect one the airow,
noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and
avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy
loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airow.
INSTALLATION OPTIONS
We recommend installing the ventilation fan by securing the main body of the fan against one ceiling
joist and using the header bars as necessary for support of the adjoining joist.
There are multiple installation congurations possible for this ventilation fan. Not all congurations are
shown. If your installation requires a variation other than those shown, consult with a licensed
contractor to determine the best installation for your project. If you are replacing an existing fan, ensure
that the new grill will adequately cover the existing opening.
Do not install ventilation fan in areas where the
duct work will require conguration as shown.
NOTE If installing in existing construction, you
must have access to space above and below
the installation location.
Turning angle too sharp Avoid duct shrink
Too many elbows Elbow near the body
Fan
body
Minimum 18 in.

Pre-Installation
— 4 —
PACKAGE CONTENTS
Part Description Quantity
AFan body 1
BInstallation bracket IV 1
CInstallation bracket II 1
DInstallation bracket I 1
EInstallation bracket III 1
FGrill 1
GLong wood screws 8
HShort screw (4X12) 2
IShort screw (4X6) 2

Installation
STEP 1
Determine joist width
•
•
Measure the distance from the center of the two ceiling joists where you will be installing the
ventilation fan.
Use the table to determine the header bar installation.
• For conguration 1, proceed to step 2.
• For conguration 2, proceed to step 3.
• For conguration 3, proceed to step 4.
Use the following to determine the proper installation conguration:
STEP 2
Conguration 1, initial install
•
•
•
•
Use long wood screws (G) to loosely attach
the main body of fan (A) to ceiling joist in the
four locations shown.
Fit bracket I (D) against the main body of fan,
ensuring the bracket is snug against the
opposite ceiling joist.
Use long wood screws to loosely attach
bracket I to the opposite ceiling joist as
shown.
Proceed to step 6.
STEP 3
Conguration 2, initial install
•
•
•
•
•
Use long wood screws (G) to loosely attach
the main body of fan (A) to the ceiling joist in
the four locations shown.
Fit bracket IV (B) against the main body of fan,
ensuring bracket I is snug against the opposite
ceiling joist.
Fit bracket I (D) against main the body of fan,
ensuring bracket IV is snug against the
opposite ceiling joist.
Use long wood screws to loosely attach
bracket I to opposite ceiling joist as shown.
Proceed to step 6.
— 5 —

Installation
— 6 —
STEP 4
Conguration 3, preparation
•
Connect bracket I (D) to bracket II (C) using
two M4x6 screws (I).
STEP 5
Conguration 3, preparation
•
•
•
•
Use long wood screws (G) to loosely attach
the main body of fan (A) to the ceiling joist in
the four locations shown.
Fit connected brackets (C, D) against the main
body of fan, ensuring they are snug against
the opposite ceiling joist.
Use long wood screws to loosely attach
bracket I and 2 (C, D) to the opposite ceiling
joist as shown.
Proceed to step 6.
STEP 6
Final installation
•
•
•
•
Ensure the main body (A) is level.
Ensure the ange on the main body is ush with the
ceiling joist.
Firmly secure all screws on the main body and any
installed brackets.
Use long wood screws (G) to secure the main body ange
to bottom of ceiling joist as shown.
STEP 7
Connect duct
•
•
Install a circular duct to outlet and secure it with duct
tape or clamps.
Install the duct to the outlet with a gradient 1°-2° to the
outside as shown.

Installation
STEP 8
Connect wiring
WARNING Wiring must comply with all applicable electrical codes. Turn OFF power before removing or
installing connectors.
WARNING COPPER TO COPPER ONLY. Do not use on Aluminum wire.
WARNING Follow all local electrical and safety codes.
CAUTION Never place a switch where it can be reached from a tub or shower.
CAUTION If your house wires do not match these colors, determine what each house wire represents before
connecting. You may need to consult a licensed electrician to determine this safely.
Match colors as shown.
STEP 9
Attach grill
•
•
Insert the mounting springs into the slots in the grill (F).
Squeeze springs together and insert into the main body.
— 7 —
4 in. to 3 in.
reducer
(provided) Tape
Tape
3 in. ducting 4 in. duct
connector
Installation with reducer
•
•
Mount the reducer directly on the original 4 in. duct
connector, and then use the duct tape to secure and seal.
Connect the pipe to the other end of the reducer, and
then use the duct tape to secure and seal.
120V AC LINE IN
GREEN & YELLOW (GRD)
WHITE WIRE (N)
BLACK WIRE (L)
BLACK WIRE
JUNCTION BOX COVER
TO FAN SWITCH

Problem
Troubleshooting
Care and Cleaning
CAUTION Do not install in locations where the air temperature will exceed 104°F (40°C).
WARNING Unplug or disconnect the appliance from the power supply before servicing.
•
•
•
•
•
•
•
To reduce the risk of re, electric shock, or injury to persons before servicing or cleaning the unit,
disconnect and lock the power supply at the panel to prevent the power from being turned on.
Before servicing or cleaning the unit, disconnect and lock the power supply at the panel to prevent
the power from being turned on.
Remove the grill by squeezing the springs and pulling down.
Wash and clean the grill in a sink and dry with a cloth.
Remove dust and dirt from the fan housing with a vacuum cleaner.
Dampen cloth with dish detergent, wipe the fan housing and dry with a cloth.
Replace the grill.
Fan will not turn on
Possible Cause
Power off
Faulty switch
Faulty wire connection
•
•
•
Corrective Action
Make sure the power supply is on
Test or replace the switch
Check wire in the switch box
•
•
•
— 8 —

Specications
5.74 in.
(145.7 mm)
3.89 in.
(99 mm)
9.13 in.
(231.9 cm)
8.46 in.
(214.8 mm)
12.6 in.
(320 mm)
Exhaust
diameter
mm (inch)
Voltage
(V)
Rate
(Hz)
Power
(W)
Rotate
speed
(RPM)
Weight
Kg. (lb.) Noise (sones)
100 (4) 120 60 24 920 4.1 (9) 1.0
— 9 —
12.6 in.
(320 mm)

© 2017 Copyright of Ancona Home. All rights reserved. This material may not be reproduced, displayed, modied or distributed.
Please register your product warranty by visiting the Ancona Home website.
Canada & USA
Phone: 1-800-350-4562
Fax: 800-350-8563
Website: www.anconahome.com
MAAN4807-01
— 10 —
Table of contents
Popular Fan manuals by other brands

Vortice
Vortice EVOLUTION LIGHT KIT Instruction booklet

Primo Water
Primo Water PRCF-80279 use instructions

Monte Carlo Fan Company
Monte Carlo Fan Company 5TLR54 Series Owner's guide and installation manual

Orbegozo
Orbegozo SF 0156 instruction manual

KDK
KDK F-M14DZ Operating and installation instructions

Schaefer
Schaefer 20CFO-SWDS Operator's manual

Delta Electronics
Delta Electronics BFB1112H Dimensions and installation information

KORADO
KORADO KORASMART 1300 instruction manual

HLU
HLU HF R 75-16 D operating manual

TJERNLUND
TJERNLUND 950-2064 L-185 SAFETY INTERLOCK KIT 8504020 REV 3... installation guide

Fanimation
Fanimation FP4650 Series owner's manual

Flexit
Flexit BR100 User and installation manual