ANTAIRA DTD-360-0953-T User manual

DTD-360-0953-T
360W Industrial DC to DC Power Booster, 9~36VDC Power Input,
53VDC Power Output, -40°C ~ 75°C
Hardware Manual
Version 1.0
(April 2023)

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
© Copyright 2023 Antaira Technologies, LLC
All rights reserved
This document contains information, which is protected by copyright. Reproduction, adaptation, or translation without
prior permission is prohibited, except as allowed under the copyright laws.
Trademark Information
Antaira is a registered trademark of Antaira Technologies, LLC, Microsoft Windows and the Windows logo are the
trademarks of Microsoft Corp. NetWare is the registered trademark of Novell Inc. WMM and WPA are the registered
trademarks of Wi-Fi Alliance. All other brand and product names are trademarks or registered trademarks of their
respective owners.
Notice: Copyrights © 2023 by Antaira Technologies, LLC. All rights reserved. Reproduction, adaptation, or translation
without prior permission of Antaira Technologies, LLC is prohibited, except as allowed under the copyright laws.
Disclaimer
Antaira Technologies, LLC provides this manual without warranty of any kind, expressed or implied, including but not
limited to the implied warranties of merchantability and fitness for a particular purpose. Antaira Technologies, LLC may
make improvements and/or changes to the product and/or specifications of the product described in this manual, without
prior notice. Antaira Technologies, LLC will not be liable for any technical inaccuracies or typographical errors found in this
guide. Changes are periodically made to the information contained herein and will be incorporated into later versions of
the manual. The information contained is subject to change without prior notice.
FCC Warning
This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to
radio communications if the equipment is not installed and used in accordance with the instructions. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
●Reorient or relocate the receiving antenna.
●Increase the separation between the equipment and receiver.
●Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
●Consult the dealer or an experienced radio/TV technician for help.

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
Caution: Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority
to operate the equipment.
Avertissement FCC
Cet équipement a été testé et déclaré conforme aux limites d'un appareil numérique de classe A, conformément à la
partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences
nuisibles dans une installation résidentielle. Cet équipement génère, utilise et peut émettre de l'énergie radiofréquence.
Cela peut provoquer des interférences nuisibles aux communications radio si l'équipement n'est pas installé et utilisé
conformément aux instructions. Cependant, il n'y a aucune garantie qu'aucune interférence ne se produira dans une
installation particulière. Si cet équipement provoque des interférences nuisibles à la réception radio ou télévision, ce qui
peut être déterminé en éteignant puis en rallumant l'équipement, l'utilisateur est encouragé à essayer de corriger les
interférences par une ou plusieurs des mesures suivantes:
●Réorientez ou déplacez l'antenne de réception.
●Augmentez la distance entre l'équipement et le récepteur.
●Connectez l'équipement à une prise sur un circuit différent de celui auquel le récepteur est connecté.
●Consultez le revendeur ou un technicien radio / TV expérimenté pour obtenir de l'aide.
CE Mark Warning
This is a Class-A product. In a domestic environment, this product may cause radio interference in which case the user
may be required to take adequate measures.
Avertissement de marque CE
Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut provoquer des interférences radio,
auquel cas l'utilisateur peut être amené à prendre des mesures adéquates.
Industrial DC to DC Power Booster
Industrial Grade DC to DC Power Booster
Hardware Manual
Version 1.0 (April 2023)
The manual supports the following model:
●DTD-360-0953-T

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
Table of Contents
1 Overview 1
1.1 Product Hardware Features 1
1.2 Package Contents 1
1.3 Safety Precaution 2
2 Hardware Description 3
2.1 Physical Dimensions 3
2.2 Front View Panel 4
2.3 Top View Panel 4
2.4 LED Indicators 5
2.5 Wiring the Power Inputs 5
2.6 Wiring the Power Outputs 6
2.7 Grounding Note 7
3 Mounting Installation 8
3.1 DIN-Rail Mounting 8
3.2 Wall Mounting 9
4 Hardware Installation 11
4.1 Installation Steps 11
4.2 Maintenance and Service 12
4.3 Troubleshooting 12

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
1 Overview
Antaira Technologies’ DTD-360-0953-T is a DC/DC Output DIN rail mounted power booster that provides up to 360 watts
of power. It is designed in compact size IP30 metal housing. DTD-360-0953-T with the booster technology is the best
solution for the applications with low voltage power source available. Besides, the -40°C to 75°C wide temperature range
design makes it perfect for operating in critical industrial environments, like automation and motivative.
1.1 Product Hardware Features
Interface and Performance
- Featuring the booster technology from 9~36VDC (up to 55VDC) power input to 53VDC
- Output voltage adjustable (48~55V) via built-in SVR
- Protection: short circuit (Output) / overload (Input)
- Protection: Input / Output reverse polarity protection
- Protection: Input Under Voltage
- LED power indicator (Input / Output)
Power Input
- Power inputs contact interface are on the front
- Support DC power inputs through 3-pin terminal block interface
Power Output
- Support DC power inputs through removable 4-pin terminal block interface
- DC output voltage is adjustable from 48 to 55 VDC by the adjusting knob
Operating Temperature
- DTD-360-0953-T: -40°C to 75°C
Case / Installation
- IP30 protection metal housing
- DIN-Rail and wall-mount design
- Installation in a Pollution Degree 2 industrial environment
- Standalone Installation
1.2 Package Contents
- DTD-360-0953-T
- Quick Installation Guide
- Wall mounting bracket set with screws
1

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
1.3 Safety Precaution
Attention: If the DC voltage is supplied by an external circuit, please use a protection device on the power supply input.
The industrial power booster’s hardware specs, ports, cabling information, and wiring installation will be described within
this hardware manual.
Attention: Si la tension continue est fournie par un circuit externe, veuillez utiliser un dispositif de protection sur l'entrée
d'alimentation. Les spécifications matérielles du booster de puissance industriel, les ports, les informations de câblage et
l'installation du câblage seront décrits dans ce manuel du matériel.
Warning Labels
The caution label means that you should check certain information on the user manual when working with the device.
(Shown in Figure 1.1)
Étiquettes d'avertissement
L'étiquette d'avertissement signifie que vous devez vérifier certaines informations du manuel d'utilisation lorsque vous
travaillez avec l'appareil. (Illustré à la figure 1.1)
Figure 1.1 - Caution Label
Figure 1.1 - Étiquette de mise en garde
Figure 1.2 - Hot Surface Warning Label
Figure 1.2 - Étiquette d'avertissement de surface chaude
2

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
2 Hardware Description
2.1 Physical Dimensions
Figure 2.1, below, shows the physical dimensions of this product series:
(W x D x H) is 30mm x 75mm x 95mm
Figure 2.1 - Physical Dimensions
3

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
2.2 Front View Panel
Figure 2.2, below, shows the front panel of the product series:
Figure 2.2 - Front View Panel
2.3 Top View Panel
Figure 2.3, below, shows the top panel of the product series:
Figure 2.3 - Top View Panel
4

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
2.4 LED Indicators
There are LED light indicators located on the front panel of the industrial power booster that display the power status.
Each LED indicator has a different color and has its own specific meaning, see below in Table 2.1.
LED
Color
Description
P1
Green
On
Power Input 1 is active
Off
Power Input 1 is inactive
P2
Green
On
Power Input 2 is active
Off
Power Input 2 is inactive
Table 2.1 - LED Indicators
2.5 Wiring the Power Inputs
Caution: Please follow the steps below when inserting the power wire.
Attention: Veuillez suivre les étapes ci-dessous lors de l'insertion du câble d'alimentation.
1. Insert the positive and negative wires into the V+ and V- contacts on the terminal block connector as shown below in
Figure 2.4.
Figure 2.4 - Power Terminal Block
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.5.
Figure 2.5 - Power Terminal Block
5

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
Caution:
Only use copper conductors, 125°C, tighten to 7 lbs.
The wire gauge for the terminal block should range between 18~20 AWG.
Attention:
Utilisez uniquement des conducteurs en cuivre, 125°C, serrez à 7 lb.
Le calibre des fils du bornier doit être compris entre 18 et 20 AWG.
2.6 Wiring the Power Outputs
Caution: Please follow the steps below when inserting the power wire.
Attention: Veuillez suivre les étapes ci-dessous lors de l'insertion du câble d'alimentation.
1. Insert the positive and negative wires into the PWR1 (+V1, -V1) and PWR2 (+V2, -V2) contacts on the terminal block
connector as shown below in Figure 2.6.
Figure 2.6 - Wiring the Fault Alarm Contact
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.7.
Figure 2.7 - Wiring the Copper Conductors to the Terminal Block
3. Rotate the knob to adjust power output voltage from 48~55VDC, as shown in Figure 2.8.
6

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
Figure 2.8 - Adjustable Knob for Power Output Voltage
2.7 Grounding Note
Grounding and wire routing help limit the effects of noise due to Electromagnetic Interference (EMI). Run the ground
connection from the ground screw to the grounding surface prior to connecting devices. The grounding screw symbol is
shown below in Figure 2.9.
Figure 2.9 - Grounding Screw Symbol
Caution: Using a shielded cable achieves better electromagnetic compatibility.
Attention: L'utilisation d'un câble blindé permet une meilleure compatibilité électromagnétique
7

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
3 Mounting Installation
3.1 DIN-Rail Mounting
The DIN-Rail is pre-installed on the industrial power booster from the factory. If the DIN-Rail is not on the industrial power
booster, please see Figure 3.1 to learn how to install the DIN-Rail on the switch.
Follow the steps below to learn how to hang the industrial power booster:
1. Use the screws to install the DIN-Rail bracket on the rear side of the industrial power booster.
Caution: The torque for tightening the screws on the device is 3.5 in-lbs.
Attention: Le couple de serrage des vis sur l'appareil est de 3.5 pouces-livres.
2. To remove the DIN-Rail bracket, do the opposite from step 1.
3. After the DIN-Rail bracket is installed on the rear side of the switch, insert the top of the DIN- Rail on to the
track as shown below in Figure 3.2.
4. Lightly pull down the bracket onto the rail as shown below in Figure 3.3.
5. Check if the bracket is mounted tightly on the rail.
6. To remove the industrial power booster from the rail, do the opposite from the above steps.
Figure 3.1 - Rear View of the Switch and DIN-Rail
8

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
Figure 3.2 - Insert the Switch on the DIN-Rail Figure 3.3 - Stable the Switch on the DIN-Rail
3.2 Wall Mounting
Follow the steps below to mount the industrial power booster using the wall mounting bracket as shown below in Figure
3.4.
Caution: “Wall” means industrial control panel wall
Attention: “Wall” signifie mur de panneau de commande industriel
1. Remove the DIN-Rail bracket from the industrial power booster by loosening the screws.
2. Place the wall mounting brackets on the top and bottom of the industrial power booster.
3. Use the screws to screw the wall mounting bracket on the industrial power booster.
Caution: The torque for tightening the screws on the device is 3.5 in-lbs.
Attention: Le couple de serrage des vis sur l'appareil est de 3.5 pouces-livres.
4. Use the hook holes at the corners of the wall mounting bracket to hang the industrial power booster on the wall.
5. To remove the wall mount bracket, do the opposite from the steps above.
9

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
Figure 3.4 - Remove DIN-Rail bracket from the Power Booster
Below, in Figure 3.5 are the dimensions of the wall mounting bracket.
Figure 3.5 - Wall Mounting Bracket Dimensions
10

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
4 Hardware Installation
4.1 Installation Steps
This section will explain how to install the industrial power booster:
Caution: This device is intended for indoor use.
Attention: Cet appareil est destiné à une utilisation en intérieur.
Caution: The device is intended to be installed in an industrial control enclosure and panel.
Attention: L'appareil est destiné à être installé dans une armoire de commande et un panneau industriels.
Installation Steps
1. Unpack the industrial power booster from the original packing box.
2. Check if the DIN-Rail bracket is screwed on the industrial power booster.
●If the DIN-Rail is not screwed on the industrial power booster, please refer to the DIN-Rail Mounting section for
DIN-Rail installation.
●If you want to wall mount the industrial power booster, please refer to the Wall Mounting section for wall
mounting installation.
3. To hang the industrial power booster on a DIN-Rail or wall, please refer to the Mounting Installation section.
4. Connect the power source equipment to the industrial power booster and then the power input LED light will turn
on.
●If you need help on how to wire power, please refer to the Wiring the Power Inputs section.
●Please refer to the LED Indicators section for LED light indication.
5. Connect the industrial power booster to the powered device, e.g.: Ethernet switch…etc., and the power output LED
light will turn on.
11

Antaira Technologies - Industrial Power Booster
DTD-360-0953-T - Hardware Manual - v1.0
●Please refer to the LED Indicators section for LED light indication.
6. When all connections are set and the LED lights all show normal, the installation is complete.
4.2 Maintenance and Service
●If the device requires servicing of any kind, the user is required to disconnect and remove it from its mounting.
The initial installation should be done in a way that makes this as convenient as possible.
●Voltage / Power lines should be properly insulated as well as other cables. Be careful when handling them so as
to not trip over.
●Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in
the different faces of the device. This may not only harm the internal layout, but might cause harm to users
as well.
●Do not under any circumstance open the device for any reason. Please contact your dealer for any repair
needed or follow the instructions within the manual.
●Clean the device with dry soft cloth.
4.3 Troubleshooting
●Verify you have the right power cord or adapter. Never use a power supply or adapter with a non-compliant DC
output voltage or it will burn the equipment.
●If the power indicator LED does not turn on when the power cord is plugged in, the user may have a problem with
the power cord. Check for loose power connections, power losses or surges at the power outlet.
◆Please contact Antaira for technical support service, if the problem still cannot be resolved.
●If the industrial power booster LED indicators are normal and the connected cables are correct, the packets still
cannot transmit. Please check the Ethernet devices’ configuration or status of the system.
Antaira Customer Service and Support
(Antaira US Headquarter) + 844-268-2472
(Antaira Europe Office) +48-22-862-88-81
(Antaira Asia Office) +886-2-2218-9733
Please report any problems to Antaira:
12
Other manuals for DTD-360-0953-T
1
Table of contents
Other ANTAIRA Extender manuals
Popular Extender manuals by other brands

ADC
ADC e-sphyg 2 user manual

ZyXEL Communications
ZyXEL Communications PLA5236 user guide

Guntermann & Drunck
Guntermann & Drunck DP-Vision-CAT Series Installation and operating guide

AVARRO
AVARRO 0E-EXT4KKVM manual

SWIT Electronics
SWIT Electronics FLOW500 Tx user manual

airwave
airwave AWX 701-A Operation manual