ANTAIRA DTD-360-0953-T User manual

Antaira Technologies
DTD-360-0953-T
360W Industrial DIN-Rail Power Booster, 9-36VDC power input,
53VDC power output, -40°C~75°C
Quick Installation Guide
Version 1.0
(April 2023)
Tel: 1-844-268-2472
Fax: 1-714-671-9944
www.antaira.com
19020000000208
Package Check List
The package contains the following items:
1 –Quick installation guide
1 –DTD-360-0953-T
2 –Wall mounting bracket set with screws
Front Panel Layout
Top Panel View
Product Overview
System Interface/Performance
Featuring the booster technology from 9-36VDC power
input to 53VDC
Output voltage adjustable (48V-55V) via built-in SVR
Protection: short circuit (Output) / overload (Input)
Protection: Input / Output reverse polarity protection
Protection: Input Under Voltage
LED power indicator (Input / Output)
Operating Temperature
Extended operating temperature model: -40°C to 75°C
Case/Installation
IP30 protection
DIN-Rail and Wall mount design
Installation in a pollution degree 2 industrial
environment
Fan-less Design, cooling by free air convection
Power Input
Power inputs contact interface are on the front panel
Support 9-36(up to 55)VDC power inputs through 3-pin
terminal block interface
Note:
1. Only use copper conductors, 125°C, tighten to 7 lbs.
2. The wire gauge for the terminal block should range between
18~20 AWG.
Power Output
Support DC power outputs through removable 4-pin
terminal block interface
DC output voltage is adjustable from 48 to 55 VDC by
the adjusting knob
Note:
1. Please adjust the knob by fine-tuning.
LED Indicators
LED
Color
Description
Input OK
Green
On
DC Input works normally
Off
DC input is failed
Output OK
Green
On
DC output works normally
Off
DC output is failed
Grounding Screw
4-Pin Removal Terminal Block for DC Power Output
4-Pin Removal Terminal Block for DC Power Output
3-Pin Terminal Block for DC Power Input
LED for Power Output Status
LED for Power Input Status
Adjustable Knob for Output
Voltage Control from 48 to 55VDC
Grounding Screw

Figure 3
Quick Installation
Power Outputs Wiring
Please follow the steps below to insert the power wire:
1. Insert the positive and negative wires into the PWR (V-,
V-, V+, V+) contacts on the terminal block connector as
shown below in Figure 1.
2. Tighten the wire-clamp screws to prevent the wires from
loosening, as shown below in Figure 2.
V- V- V+ V+
Figure 1 Figure 2
Industrial PoE Injector Mounting
DIN-Rail Mounting
The DIN-Rail bracket is pre-installed on
the industrial PoE injector from the
factory. Please refer to Figure 3 for a
DIN-Rail bracket installation reference.
Follow the steps below for installing the
industrial PoE injector on the DIN-Rail
track:
1. Insert the top of the DIN-Rail onto
the track as shown below in Figure 4.
2. Lightly pull down the bracket onto
the rail as shown below in Figure 5.
3. Check if the bracket is mounted tightly on the rail.
4. To remove the industrial PoE injector from the rail, do the
opposite from the steps above.
Wall Mounting
Follow the steps below to mount the industrial PoE injector using
the wall mounting bracket as shown in Figure 6.
1. Remove the DIN-Rail bracket from the industrial PoE
injector by loosening the screws.
2. Place the wall mounting brackets on
the top and bottom of the industrial
PoE injector.
3. Use the screws to screw the wall
mounting bracket on the industrial
PoE injector.
4. Use the hook holes at the corners of
the wall mounting bracket to hang the
industrial PoE injector on the wall.
5. To remove the wall mount bracket, do
the opposite from the steps above.
Field Maintenance and Service
If the device requires servicing of any kind, the user is
required to disconnect and remove it from its mounting. The
initial installation should be done in a way that makes this as
convenient as possible.
Voltage/power lines should be properly insulated as well as
other cables. Be careful when handling them so as to not trip
over.
Do not under any circumstance insert foreign objects of any
kind into the heat dissipation holes located in the different
faces of the device. This may not only harm the internal
layout, but might cause harm to the user as well.
Do not under any circumstance open the device for any
reason. Please contact your dealer for any repair needed or
follow the instructions within the manual.
Warranty Policy
Warranty Conditions
Products supplied by Antaira Technologies are covered in
this warranty for sub-standard performance or defective
workmanship. The warranty is not, however, extended to
goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric
shock, earthquake
(c) Use of unqualified power supply, connectors, or
unauthorized parts/kits
(d) Replacement with unauthorized parts
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized "RMA" number
from Antaira before shipping the goods for repair or
replacement.
Within the warranty period (based on the invoice date), all
parts and labor are free of charge to the customers.
Customers are responsible for the cost of parts and labor,
if the products are out of warranty.
For RMA service, customers are responsible for the
shipping expense for shipping the RMA unit(s) to Antaira.
Antaira is responsible for the shipping expense via a
ground service for the return repair/replace unit(s) back to
customers.
Limited Liability
Antaira would not be held responsible for any consequential
losses from using Antaira’s product.
Warranty Period
5-Year Warranty
Antaira’s Customer Service and Support
Antaira’s Technical Service & Support Centers:
+ 844-268-2472 (Antaira US Headquarter)
+ 48-22-862-88-81 (Antaira Europe Office)
+ 886-2-2218-9733 (Antaira Asia Office)
Antaira’s Web Sites & Repair/Support Emails:
*Any changes will be announced on the Antaira
website.
Figure 6
Figure 5
Figure 4
Other manuals for DTD-360-0953-T
1
Other ANTAIRA Extender manuals