PROFESSIONAL DIGITAL AMPLIFIER
Safety First!
• Caution! This professional device needs to be installed by
qualified personnel only.
• Please check the carton box for any kind of damage on
reception of the goods. In case of a damaged carton, please
contact your dealer before opening the carton.
• !!!! Danger !!!! Exposure to high sound levels may cause a
permanent hearing loss. Individuals vary considerably to sound
pressure level induced hearing loss but nearly everyone will
lose some hearing if exposed to high sound pressure levels for
a sufficient amount of time. Therefore it is recommended that
all persons exposed to equipment capable of producing high
sound pressure levels, such as this amplifier, be protected by
hearing protection while installing or operating this unit.
• Read all documentation before operating your equipment.
• Keep all documentation for future reference.
• Save the carton and packing material even if the equipment has
arrived in good condition.
• Should you ever need to ship the unit, use only the original
factory packing.
• Do not spill water or other liquids into or on the unit.
• Make sure power outlets conform to the power requirements
listed on the back of the unit.
• Do not use the unit if the electrical power cord is frayed or
broken.
• Always operate the unit with the AC ground wire connected to
the electrical system ground.

Instruction manualREVAMP1680
5
• Set level controls on amplifiers all the way down during power-
up to prevent speaker damage if there are high signal levels at
the inputs.
• Do not connect the inputs / outputs of amplifiers or consoles
to any other voltage source, such as a battery, mains source, or
power supply, regardless of whether the amplifier or console is
turned on or off.
• Power down & disconnect units from mains voltage before
making connections.
• Do not use the unit near stoves, heat registers, radiators, or
other heat producing devices.
• Do not operate equipment on a surface or in an environment
which may distort the normal flow of air around the unit. If the
unit is used in an extremely dusty or smoky environment, the
unit should be periodically “blown free” of dust.
• Do not remove the cover. Removing the cover will expose you
to potentially dangerous volt ages.
• Do not drive the inputs with a signal level higher than that
required to drive equipment to full output.
• Do not run the output of any amplifier back into another input.
• In case of mal-function this device should be serviced by
qualified service personnel only.
• This unit has NOT been designed for use in mobile applications,
such as: mobile discobars, mobile PA systems, Live bands, audio
rental systems, …
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER OR BACK
NO USER-SERVICEABLE PARTS INSIDE
SERVICING ONLY FOR QUALIFIED PERSONNEL

6
PROFESSIONAL DIGITAL AMPLIFIER
Features
• 3 rack units high
• 16 output Channels powered with D-Class amplifiers
• 16 x 80 watts (4 ohms) or 8x160 watts (8 ohms) sine wave
output power
• Very high channel seperation
• 8 stereo output zones
• High thermal efficiency
• Highest possible damping factor
• Dual analog power supply with toroidal power transformers
• Switching mode standby power supply with multiple auto
power on/off options: trigger, audio sense, …
• Low power consumption, less than 0.5 W in standby
• Intelligent thermal power limiting circuit: limits the output
power to a safe limit whenever a thermal overload occurs
• Individual unbalanced inputs on RCA per zone
• 2 stereo input buses selectable for all stereo output zones, with
passthrough
• Input level attenuators on all inputs
• Euroblock speaker connectors
• Extended speaker and amp protection circuits: DC protect, over
current protect, over temperature protect
• Versatile LED status indicators

Instruction manualREVAMP1680
7
• This unit has NOT been designed for use in mobile applications,
such as: mobile discobars, mobile PA systems, Live bands, audio
rental systems, …
• Removable rack-ears
This amplifier is equipped with 2 stereo bus inputs with
passthrough. These bus inputs are ideal when you want to hear the
same audio signal in different output zones. For example: zones 1
to 4 use bus 1 input. Zones 5 to 7 use bus 2. Zone 8 is set to line
in and uses its own input signal. In this case, set the input selector
for zone 1 to 4 to bus 1, from zone 5 to 7 to bus 2 and zone 8 to
line in.
The trigger input is ideal when you want to switch on the power
amplifier automatically using an external AC or DC trigger signal
coming from your audio system. The amplifier will be switched on
as long as the trigger voltage is present. Alternatively, you can set
the power on mode switch to the audio trig position: the amp will
automatically switch on when a sufficiently strong audio signal
is present at the input. The input sensitivity for the audio trigger
function is 15 mV on all inputs. After a few minutes of silence, the
amplifier will automatically switch itself off.

8
PROFESSIONAL DIGITAL AMPLIFIER
1. Bus 1 unbalanced stereo input on RCA connector: This input
can be selected in any zone by setting switch “10” to the BUS
1 position.
2. Bus 2 unbalanced stereo input on RCA connector: This input
can be selected in any zone by setting switch “10” to the BUS
2 position.
3. Bus 1 unbalanced stereo pass through on RCA connector: the
audio signal applied to the BUS 1 input can be tapped here.
4. Bus 2 unbalanced stereo pass through on RCA connector: the
audio signal applied to the BUS 2 input can be tapped here.
Connections (only output zone 1 is explained. Zone 2 –
8 are identical)
10
11
12
13
14 15
1 8
3 5 7
4 6
2 9

Instruction manualREVAMP1680
9
5. Power on mode selector: power on: the amplifier is powered
on when the power switch at the front panel is switched to
the on position. In the Audio Trig position, the amplifier will be
switched on automatically when a strong audio signal is present
at the input. In the Ext Trigger position, you have to apply a
3-30 V AC or DC voltage at the jack input “6”. The power
switch on the front panel must be in the on position. In the off
position, the amplifier will always be off.
6. Trigger input jack: 3.2 mm monojack input for the 3-30 V AC
or DC trigger voltage. The trigger voltage will switch on the
amplifier when switch “5” is in the Ext Trigger position and the
front panel power switch is in the on position.
7. Ext Trigger output jack pass through (out) connector, 3.2 mm
mono minijack: the trigger voltage applied at connector “6” is
passed through via this connector.
8. Channel input gain setting. Adjust the input gain to the output
level of your source.
9. Amplifier mode selector: set to stereo for normal operation, set
to bridge for bridged mode. Load impedance in bridged mode
must be 8 ohms or higher.
10. Input selector for zone 1. Select Bus 1, Bus 2 or Line in.
11. Zone 1 stereo speaker outputs on euroblock. Minimum load
impedance is 4 ohms in stereo mode and 8 ohms in bridge
mode.
12. Line in: unbalanced stereo input on RCA connector. In bridge
mode: use left input only.
13. Mains inlet connector: connect the mains cable supplied with

10
PROFESSIONAL DIGITAL AMPLIFIER
Operation
the unit here.
14. Mains fuse: when the fuse blows, replace only with the same
type and fuse rating.
15. Mains voltage selector: set to 230 or 115VAC according to your
local mains voltage.
1. Removable rack ears for 19” rack mounting.
2. Power switch.
3. Power led.
4. Zone 1 - 8 status leds: green = active, red = inactive, protect or
overload.
1 12 3 4

Instruction manualREVAMP1680
11
!!!IMPORTANT!!!
This amplifier relies on convection and active cooling. In normal
situations, overheating will not occur. The unit can be built in a
19” inch rack system, but it is forbidden to block the ventilation
holes provided. Therefore, it is absolutely necessary to allow at least
one free rack space or 44 mm above and beneath the amplifier.
Make sure the ambient temperature is between 0 and 40°C.
Operating the unit beyond its normal limits will result in excessive
internal temperature. Power amplifiers are hard workers, and
their behaviour is similar to human beings. In extreme conditions,
human beings are not able to perform efficiently. This also applies
to amplifiers. It is generally a bad idea to mount multiple heat
generating units such as amplifiers in the same rack. If necessary,
use an additional forced ventilation system in your mounting rack.
The mains fuse is located inside the unit. When the fuse is broken,
replace it with a fuse of the same current and voltage rating:
8 AT/250V for 230 VAC operation or 15 AT/250V for 115 VAC
operation. For qualified personnel only!
This unit has NOT been designed for use in mobile applications,
such as: mobile discobars and DJ setups, mobile PA systems, live
bands, audio rental systems, …
Use it in fixed installations only.

12
PROFESSIONAL DIGITAL AMPLIFIER
Technical specifications
Dynamic program power per
channel
100 W @ 4 Ω
Sine wave power per channel 80 W @ 4 Ω
Sine wave power bridge mode 160 W @ 8 Ω
Load impedance minimum 4 Ω in stereo mode,
minimum 8 Ω in bridge mode
Input connections 2 x stereo bus with pass through,
unbalanced on RCA + individual
unbalanced zone inputs on RCA
Input sensitivity 500 mV
Input impedance 22 kΩ
S/N ratio > 98 dB A weighted
THD < 0.5% @ 1 W / 4Ω / 1 kHz A
weighted
Frequency response 20 – 30 kHz +0 / -3dB
Protection circuits over current, over temperature,
DC offset, AC and DC over- and
undervoltage
Channel separation > 68dB @ 1kHz
Damping factor > 60 all channels
Power amp topology class D
Power supply toroidal transformers & switching
mode standby power supply
Cooling convectional
Max power consumption 1350 W

Instruction manualREVAMP1680
13
Standby power consumption < 0.5 W
Operating temperature range 0 to 40°C
Mains operating voltage 230 VAC / 50 Hz – 115 VAC / 60 Hz
Dimensions 483 x 132 x 411 ( including rack
ears)
Net weight 21.7 kg
Gross weight 24 kg

14
PROFESSIONAL DIGITAL AMPLIFIER


developed
by
Audioprof nv
Industriepark Brechtsebaan 8 bus 1
2900 Schoten - Belgium
Company names, product names and trademarks are property of their
respective owners.
Apart-Audio specifications are subject to change without notice.
Table of contents
Other APART Amplifier manuals

APART
APART MA-35 User manual

APART
APART PA8250 User manual

APART
APART REVAMP4120T User manual

APART
APART REVAMP8250 User manual

APART
APART Concept 1T User manual

APART
APART vinci 2125 User manual

APART
APART SB-160 User manual

APART
APART PA-CONF-E User manual

APART
APART REVAMP1120T User manual

APART
APART REVAMP4240T User manual

APART
APART MA125 User manual

APART
APART CHAMP-3D User manual

APART
APART Champ-2 User manual

APART
APART PM7400 MKII User manual

APART
APART PM7400 MKII User manual

APART
APART MA247 series User manual

APART
APART PA4060 User manual

APART
APART MA200 User manual

APART
APART PIR7600 User manual

APART
APART CONCEPT1 User manual