WATER METER TYPE
Ultrasonic water meters
with copper body and
integrated RF connectivity
Ultrimis UL
DN15-50
Ultrasonic water meters
with composite body and
integrated RF connectivity
Ultrimis UL-01
DN15-20
CE, MID, IP68, WM-Bus, LoRaWAN CE, MID, IP68, WM-Bus, LoRaWAN
SHIPPING AND STORAGE
Protect against shocks and vibration.
Store between 0°C and 25°C.
BASIC INFORMATION
ESSENTIAL INSTALLATION COMPONENTS
CLASSIFICATION OF ENVIRONMENTAL CONDITIONS
- Environmental classification – Climate and mechanical conditions: Class B(EN ISO 4064: 2014)
- Environmental classification – mechanical conditions: Class M1 (Directive 2014/32/UE of 26 February 2014)
- Electromagnetic conditions: Class E1 & E2 (EN ISO 4064: 2014 and Directive 2014/32/UE of 26 February 2014)
COMPATIBILITY AND INSTALLATION REQUIREMENTS
WM-Bus03A NFC
EU868MHz
Operating
orientation
M
Ultrimis UL, UL-01 U0 D0 U5 D3
Apator Powogaz half unions G g d L Index
DN 15 mm kit of half unions w/gaskets ¾” ½” 17 mm 37.5 0616-100-018
DN 20 mm kit of half unions w/gaskets 1” ¾” 23 mm 45.5 0616-100-019
DN 25 mm kit of half unions w/gaskets 1¼” 1” 29 mm 46.5 0616-100-021
DN 32 mm kit of half unions w/gaskets 1½” 1¼” 36 mm 56.0 0616-100-026
DN 40 mm kit of half unions w/gaskets 2” 1½” 41 mm 67 0616-100-020
ULTRIMIS WATER METER INSTALLATION & OPERATING MANUAL
Ultrimis ***
UL2,5 DN15 17 29 25 Nm
UL2,5-01 DN15 17 29 15 Nm
UL4 DN20 20 36 30 Nm
UL4-01 DN20 20 36 20 Nm
UL6,3 DN25 36 47 35 Nm
UL10 DN32 44 54 40 Nm
UL16 DN40 50 67 45 Nm
UL25 DN50 24 24 -
Battery life 16 years max.**
Two integrated 3.6 V DC lithium batteries,
size AA
* 10 bar is available on special order.
** Depending on the configuration and ambient
conditions.
*** The actual installation may feature other connection fitting dimensions.
ACCESSORIES
Smartphone TestBox
Android, NFC Available for 433 MHz or 868 MHz service, de-
pending on the water meter’s RF module version
Smartphone app
Android, NFC
Max water temperature 70°C
Ambient temperature 5-55°C
Operating pressure 16 bar*
RF connectivity
parameters:
Flanged DN50 port gasket acc. to PN-EN 1514-1:2001
868 MHz up to 25 mW E.R.P.
434 MHz up to 10 mW E.R.P.
Communication
standard:
WM-Bus, OMS-compliant
LoRaWAN V1.0.4-compliant