manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. APG
  6. •
  7. Cash Register
  8. •
  9. APG VASARIO Series Installation and operating instructions

APG VASARIO Series Installation and operating instructions

VASARIO™SERIES CASH DRAWER
INSTALLATION & MAINTENANCE INSTRUCTIONS
This information applies to the Vasario™ electronically and manually activated
cash drawers.
GETTING STARTED
Prepare a location for the cash drawer. Recommendations for a suitable location
include:
· A sturdy, level surface no less than the size of the cash drawer
· Operating temperature from 40° F to 105° F (5° C to 40° C)
· Operating, non-condensing relative humidity from 10% to 90%.
LOCK FUNCTIONS – ELECTRONICALLY- ACTIVATED CASH DRAWER
The key lock provides four functions: locked closed/open, electrically on-line, and
manually open. See Figure 1. The key may be removed in the 12 o’clock
(Electrically On-Line), or 3 o’clock (Locked Closed/Open) positions.
Figure 1
LOCK FUNCTIONS – MANUALLY-ACTIVATED CASH DRAWER
The key lock provides two functions: locked open, and locked closed/opened. See
Figure 2. The key may be removed in the 12 o’clock (Locked Open), or 3 o’clock
(Locked Closed) positions.
Figure 2
Lock Notes: Two keys are included with each cash drawer for the manual lock. To
reduce the risk of damaging or breaking the key, avoid leaving it in the lock during
normal operation.
REMOVING THE DRAWER
Open the cash drawer and remove the plastic coin and bill tray. Grasp the drawer by
the sides of the front and lift the drawer up until it stops. Tip the front of the drawer
down and pull the drawer out at an inclined angle.
See Figure 2
Figure 2
Caution: Be careful not to damage the lock bar mounted on the bottom of the
drawer.
REPLACING THE DRAWER
With the drawer front tipped down at an inclined angle, insert the drawer into the
case about 2 inches. Lift the drawer up until it stops, and pull the drawer out until it
stops and drops into operating (horizontal) position.
See Figure 3. When the inner drawer is fully inserted, verify that the drawer opens
and closes properly.
PREVENTATIVE MAINTENANCE
Every six months the cash drawer slides should be cleaned and lubricated. Using a
dry, lint free cloth, wipe out the old grease, along with any accumulated dirt or
debris, from the tracks and on the wheels. Do not use water or any type of liquid
cleaner. After the old grease has been removed, apply a thin layer of lithium bearing
grease to the front and rear wheels.
PARTS AND ACCESSORIES
Contact your supplier for parts and accessories for your cash drawer.
CAUTION: Breaking coin rolls on the edge of the drawer front or plastic cash
tray may damage the drawer front or cause the plastic to fracture.
V-23-E Rev A
MultiPRO®InterfaceProduct Guidefor
Electronically-ActivatedVasarioTMCashDrawer
Model320/420Interface
© 2000 APG® Cash Drawer, Minneapolis, MN, U.S.A. V-23-E Rev A
The MultiPRO®Interface has been designed to connect APG cash drawers to various
Point of Sale receipt printers or terminals using interchangeable and detachable cables.
A drawer open/closed switch included in the cash drawer is used to report status. The
cash drawer connector is an RJ45 (8-pole) receptacle either in the base or the divider.
Model 320 MultiPRO®Interface is used for 24VDC applications.
Model 420 MultiPRO®II Interface is used for 12VDC applications.
Cash Drawer Connector Pinout:
Model: 320 420
Pin 1 üüChassis Ground
2 üüDrawer Status (Common)
3 üüStatus (Switched to Common when Drawer Closed)
4 üüStatus (Switched to Common when Drawer Open)
5 n/u üSolenoid 12VDC (–)
6 ün/u Solenoid 24VDC (–)
7 ün/u Solenoid 24VDC (+)
Pin 8 n/u üSolenoid 12VDC (+)
See APG Cable Connectivity Guide for specific interface cables.
Contact APG at 763-571-5000 (email: support@apgcd.com or Web page:
www.apgcd.com) or an authorized APG distributor for additional technical support.

This manual suits for next models

2

Popular Cash Register manuals by other brands

Sam4s SPS-500 Operator's guide

Sam4s

Sam4s SPS-500 Operator's guide

Anker EFT operating manual

Anker

Anker EFT operating manual

Casio SR-C550 Complete manual

Casio

Casio SR-C550 Complete manual

Sharp ER-A410 Service manual

Sharp

Sharp ER-A410 Service manual

Sharp XE-A42S instruction manual

Sharp

Sharp XE-A42S instruction manual

Royal 410DX instruction manual

Royal

Royal 410DX instruction manual

Sharp XE-A507 Manual de instrucciones

Sharp

Sharp XE-A507 Manual de instrucciones

Sharp XE-A107 user manual

Sharp

Sharp XE-A107 user manual

Casio SE-C300 Operation manual

Casio

Casio SE-C300 Operation manual

CashConcepts CCE 1500 manual

CashConcepts

CashConcepts CCE 1500 manual

National Cash Register Class 500 user manual

National Cash Register

National Cash Register Class 500 user manual

Casio TE-2400 user manual

Casio

Casio TE-2400 user manual

Sharp UP-3301 installation manual

Sharp

Sharp UP-3301 installation manual

Sharp XE-A106 quick start guide

Sharp

Sharp XE-A106 quick start guide

Sam4s ER-350 II SERIES Operator's and programming manual

Sam4s

Sam4s ER-350 II SERIES Operator's and programming manual

Optimas OP-880 manual

Optimas

Optimas OP-880 manual

ELCOM Euro-500T Handy Service manual

ELCOM

ELCOM Euro-500T Handy Service manual

Klemsan Klecard user guide

Klemsan

Klemsan Klecard user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.