ApisProtect Monitor 3.0 User manual

ApisProtect Monitor 3.0 User Manual
Document Number: 202101-3.0
Version: 1.00
Document Date: January 2021

ApisProtect, The Rubicon Centre CIT Campus, Bishopstown, Co. Cork, Ireland, T12 Y275
www.apisprotect.com Page 1 of 10
Table of Contents
Page
Product 2
Product Description 2
Intended Use 3
Cleaning and Maintenance 4
Technical Information 7
Certification and Compliance 8
Disposal 8
ApisProtect Contact 9

ApisProtect, The Rubicon Centre CIT Campus, Bishopstown, Co. Cork, Ireland, T12 Y275
www.apisprotect.com Page 2 of 10
Product
ApisProtect Monitor Version 3.0.
Product Description
The ApisProtect Monitor is a battery powered device and is fitted to the inside outer cover of a honey
bee hive.
Depending on the model purchased it monitors temperature, humidity, carbon dioxide, air pressure,
sound and acceleration.
These are reported via LoRa or cellular communications to the cloud where the data is analysed
against aggregate data by machine learning algorithms.
The condition of each colony and suggested actions for improved colony health are then delivered via
an application.
Figure 1.1: Parts of the ApisProtect monitor

ApisProtect, The Rubicon Centre CIT Campus, Bishopstown, Co. Cork, Ireland, T12 Y275
www.apisprotect.com Page 3 of 10
Intended Use
The ApisProtect Monitor is intended to monitor and report honey bee (Apis mellifera) hive health from
inside the bee hive. It provides suggestions to help with problems such as swarming, overheating,
freezing, queen problems, starvation, disease and pests.
Please note that the ApisProtect Monitor is not designed for exposure to the elements nor to be
submerged fully in water.
Recommendations for use
Please install the device(s) as per the installation instructions provided in the box.
With each monitor are 5 hive labels. These are to be used to label the roof and each of the boxes of
the same hive being monitored by that monitor.
Each label has the monitor number and a coloured shape to help match specific hive parts to the
monitor attached to the roof. These labels are used to help maintain consistent monitoring of the
same honey bee colony, which ensures valid predictions for that hive. They will also help the
beekeeper to identify a hive that has been alerted as requiring investigation through the ApisProtect
Alerts.
For accurate predictions, a colony should be monitored for a minimum of two weeks.

ApisProtect, The Rubicon Centre CIT Campus, Bishopstown, Co. Cork, Ireland, T12 Y275
www.apisprotect.com Page 4 of 10
Technical Information
Manufacturer:
ApisProtect Limited
Address: The Rubicon Centre, Bishopstown, Co. Cork, Ireland, T12 Y275
Company Number: 598759
Website: www.apisprotect.com
Contact: [email protected]
Manufactured in Ireland by Gentian Services Limited for ApisProtect Limited.
Accessories:
• Replacement Batteries
• Replacement Battery Cover
• Replacement Insert
Warnings
Do not transfer the ApisProtect Monitor between hives as this may result in the
unintended transfer of pathogens and pests.
If the ApisProtect Monitor is used in a manner not specified by ApisProtect then the
protection provided by the device may be impaired.
Please do not attempt to modify the device in any way or use accessories not specified
by ApisProtect. Any attempt to do so will invalidate the warranty and may
compromise the safety of the device.

ApisProtect, The Rubicon Centre CIT Campus, Bishopstown, Co. Cork, Ireland, T12 Y275
www.apisprotect.com Page 5 of 10
Please dispose of batteries in accordance with national local regulation.
Explanation of Symbols
The following markings and symbols may appear on the ApisProtect Monitor device or in the manual:
Please Read and follow the instructions in the manual.
Warning, Caution and Precaution to note.
Important.
CE Mark
Federal Communications Commission
Manufactured By
Temperature Range
Humidity Range
WEEE: Waste Electronic and Electrical Equipment. Dispose of in accordance
with national current regulation

ApisProtect, The Rubicon Centre CIT Campus, Bishopstown, Co. Cork, Ireland, T12 Y275
www.apisprotect.com Page 6 of 10
ApisMonitor Device Ratings
If the ApisProtect Monitor is used in a manner not specified by ApisProtect then the
protection provided by the device may be impaired.
WEEE: Waste Electronic and Electrical Equipment. Dispose of in accordance with
national current regulation.
Size: 181.5 mm x 76 mm x 15 mm (7 2/10’’ x 3’’ x 6/10’’)
Weight: 145 g (5 oz) (including batteries)
Altitude: Up to 2,000 m (6560 ft)
Input: Nominal 3.0 V supplied by 4xAAA, Min 1.7V, Max 3.2 V
Batteries: 4x AAA recommended Type Procell AAA (L03) PC2400
Alkaline-Manganese Dioxide Battery nominal Voltage 1.5V

ApisProtect, The Rubicon Centre CIT Campus, Bishopstown, Co. Cork, Ireland, T12 Y275
www.apisprotect.com Page 7 of 10
Environmental
Operating Range
Temperature:
-20°C to +55°C (0F to +130F)
Humidity:
0% to 100% RH
The instrument will function outside of these temperature ranges, however best accuracy of
measurement is achieved within this range.
Transport and Storage Range
Temperature:
-20°C to +55°C (0F to +130F)
Humidity: 5% to 90% RH (Non-condensing)
The instrument can be transported and stored outside these ranges for short periods without
affecting performance.
Certification and Compliance
This device complies with Part 15 of the FCC Rules
This device contains FCC ID VPYCMABZ
The device complies with
EN 300 220-2 V3.1.1
EN 300 220-1 V3.1.1
EN 301 489-1 V2.2.3
EN 301 489-3 V2.1.1
IEC 61010-1 2010 A1:2016

ApisProtect, The Rubicon Centre CIT Campus, Bishopstown, Co. Cork, Ireland, T12 Y275
www.apisprotect.com Page 8 of 10
Cleaning and Maintenance
It is recommended to check the holes in the silicon insert are clear of wax and/propolis when opening
the hive. If they are blocked, they can be cleared using a toothpick. If the insert is damaged or too
coated in debris a replacement can be ordered by contacting ApisProtect.
The silicon insert can be removed using a hive tool or similar.
Should you need to restart the ApisProtect Monitor please remove the batteries and reinstall them.
The ApisProtect Monitor requires four AAA batteries to function correctly.
Disposal
Please respect the environment.
Dispose of the packaging according to the local recycling regulations.
Dispose of batteries in accordance with national local regulation.
Dispose of the appliance at the end of its life span according to environmental considerations. Please
contact your local authority for details on safe disposal.
Packaging parts, and especially plastic bags, may represent a suffocation hazard.
Supplier's Declaration of Conformity
47 CFR § 2.1077 Compliance Information
Unique Identifier: ApisProtect Monitor, Version 3.0
Responsible Party – U.S. Contact Information
ApisProtect
Contact Dennis Kautz
46533 270th St,
Tea,
SD 57064,
USA
Tel. 605-370-7792
Email dkautz@apisprotect.com
FCC Compliance Statement (e.g., products subject to Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.

ApisProtect, The Rubicon Centre CIT Campus, Bishopstown, Co. Cork, Ireland, T12 Y275
www.apisprotect.com Page 9 of 10
ApisProtect Contact
Cork Office Address:
ApisProtect,
The Rubicon Centre,
Bishopstown,
Co. Cork, Ireland,
T12 Y275
Email:
General enquires: enqu[email protected]
Support: support@apisprotect.com
Website:
General: www.apisprotect.com
Dashboard: https://dashboard.apisprotect.com/
Table of contents
Popular Measuring Instrument manuals by other brands

ZONE Medical
ZONE Medical ELE600M quick start guide

PCB Piezotronics
PCB Piezotronics IMI SENSORS 66103PPZ1 Installation and operating manual

Hanna Instruments
Hanna Instruments HI 83215 instruction manual

METER
METER AQUALAB TDL quick start

MCE
MCE R.45.TC.PRO Operator's manual

YSL
YSL SC-5-CFS instruction manual

Berner
Berner BCLL TOP Instruction manual/safety instructions

CST/BERGER
CST/BERGER iLMXT Original instructions

Alpha Moisture Systems
Alpha Moisture Systems SADPmini2 quick start guide

HBX
HBX SensorLinx BTU-0014 installation guide

YOKOGAWA
YOKOGAWA DAQSTATION DX100 technical information

envea
envea PicoFlow operating instructions