Standing by
Fast ID Beacon
Packing List
1082 Smart Switch.
30VDC PSU (100-250VAC mains input).
# SB-301A2F-11
Mains lead (IEC).
UK / USA / EUR / Other
Beacon Connection Cable
# CHA-1082-4000
Manual
# CHA-1082-8000
Acoustic Support Disc
# BCN-1010-8002
Quick Start Guide
1082 Smart Switch
Channel Configuration
Connect 1082 Smart Switch to 1000 / 1100
series beacon using pigtail supplied.
Switch Beacon to ON.
Press to wake up 1082 Smart Switch if
asleep.
Press to cycle thru menus, locate - Fast
ID Beacon, press to identify beacon.
Display will indicate Beacon Model and
Channel Set.
Select Beacon Config to change beacon
parameters.
Fast Charging
Connect 1082 Smart Switch to 1000 / 1100
series beacon using pigtail supplied.
Switch Beacon to CHAR.
Connect external Power Supply to 1082.
Press to wake up 1082 Smart Switch if
asleep.
Press to cycle thru menus, locate - Fast
Charge, press to select.
Unit will prompt for external power if not
connected.
Else press to begin charge.
WARNING: - The sealed beacon must be vented to
atmosphere before and after a charge cycle by
manually operating the pressure relief valve (PRV).
Refer to 1000 series beacon manual.
Cabling
Smart Switch DC Input Cable
Beacon Connection Cable
Fast Charge Status / Trickle Charge
Beacon Model and Configuration Messages
An identified beacon model and configuration is
displayed as a scrolling message to the user. This
message is composed from the following: -
“MDL=1019D” Beacon model
“OPT=1,3” Enabled options
“CFG=AAE” AAE “channel” configuration
“CFG=SIGMA2” AAE Sigma2™configuration
“CFG=IXB” iXBlue compatible
configuration
“CFG=SWB” Sonardyne Wideband™
compatible configuration
Message is completed as follows: -
AAE “Channel” configuration
“CH=01” AAE “channel”
AAE Sigma2™configuration
“QS=1” “Quickset” configuration
“WUT=0” Wake-Up Tone
“IC=00” Interrogate Code
“RC=00” Reply Code
“TATX=0100ms” Turn-Around-Time Extension
iXBlue compatible configuration
“IF=19.5kHz” Interrogate Frequency
“RC=00” Reply Code
“TAT=020ms” Turn-Around-Time
Sonardyne Wideband™ compatible configuration
“QS=A1” “Quickset” configuration
“IC=CIF” Interrogate Channel
“ACA=0101” Acoustic Command Address
“TAT=062.5ms” Turn-Around-Time
Example
“MDL=1019D CFG=AAE CH=01”
Applied Acoustic Engineering Ltd has made every
effort to ensure that the information contained in this
guide is correct at time of print. However our policy of
continual product improvement means that we cannot
assume liability for any errors which may occur.
Attempting serial communication with beacon
Smart Switch internal battery charge
Serial communication inactive
Serial communication active with beacon
Trickle charge or fast charge active
INFORMATION /
INSTRUCTION
The Smart Switch does not include a power switch; the unit is ‘always on’. After two minutes of no user activity,
i.e. no key presses, the Smart Switch will revert to very low power standby with a blank display. In standby,
pressing any selection key will ‘wake’ the Smart Switch to its state prior to standby.