manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aprilaire
  6. •
  7. Fan
  8. •
  9. Aprilaire 8190FF User manual

Aprilaire 8190FF User manual

Other Aprilaire Fan manuals

Aprilaire 8100 User manual

Aprilaire

Aprilaire 8100 User manual

Aprilaire 8142 User manual

Aprilaire

Aprilaire 8142 User manual

Aprilaire 8192A User manual

Aprilaire

Aprilaire 8192A User manual

Aprilaire 8100 User manual

Aprilaire

Aprilaire 8100 User manual

Aprilaire 8100 User manual

Aprilaire

Aprilaire 8100 User manual

Aprilaire 8142A User manual

Aprilaire

Aprilaire 8142A User manual

Aprilaire ARNHPF Manual

Aprilaire

Aprilaire ARNHPF Manual

Aprilaire 8145A User manual

Aprilaire

Aprilaire 8145A User manual

Aprilaire 8144NC User manual

Aprilaire

Aprilaire 8144NC User manual

Aprilaire 8145NC User manual

Aprilaire

Aprilaire 8145NC User manual

Aprilaire 8140 User manual

Aprilaire

Aprilaire 8140 User manual

Aprilaire 8100 User manual

Aprilaire

Aprilaire 8100 User manual

Aprilaire 8191 User manual

Aprilaire

Aprilaire 8191 User manual

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

WARNING
1. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power
disconnected until installation/service is completed.
2. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling duct work.
CAUTION
Do not force damper blades by hand, as damage to the product may occur.
NOTE: The E100V dehumidifier contains all necessary components to power the 8190FF. The required transformer and power harness are not included
with the 8190FF. Aprilaire recommends 18-22 AWG wire and model 4010 or equivalent 24VAC transformer (10 VA min.) for use with any dehumidifier
other than the E100V.
Model 8190FF Ventilation Plenum
for Dehumidifier
Installation Instructions
OPERATION
The Model 8190FF is a ventilation plenum that can be installed to any
Model E100 or Model 1850 dehumidifier.
• Ventilation is controlled by the VENT terminals on the dehumidifier
user interface. Ventilation set up can be found in the dehumidifier
Installation and Operation Manual.
• When not powered, the 6" ventilation duct is closed while the 10" return
duct is open to allow for dehumidification of the air in the home.
• When ventilating (powered), the return duct closes while the ventilation
duct opens to allow fresh air to enter the home.
INSTALLING THE 8190FF TO THE DEHUMIDIFIER
NOTE: The control must be installed on the top of the dehumidifier. Refer
to the dehumidifier Installation and Operation Manual for details on
moving the control.
1. Remove the duct collar, if installed, from the dehumidifier inlet and
install it on the 10" opening of the 8190FF using the supplied #6
screws. Use the remaining #6 screws to install the included 6" duct
collar in the 6" opening. NOTE: Always install the 10" collar on the
8190FF to prevent anything from impinging operation of the damper.
2. Install two of the supplied #10 screws to the top holes around the
dehumidifier inlet leaving approximately 1/8" space between screw
head and cabinet.
3. Hang the 8190FF on top screws then install bottom screws and
tighten all four.
NOTES:
• Ensure the "Airflow Adjustment" thumb screw is in the "+" position and
tightened down.
• The 8190FF cabinet is insulated – do not insulate the actuator.
INTERIOR AIR ONLY VENTILATING
E100V
WIRING
PORT
6" FRESH
AIR INTAKE
COLLAR
10" INLET AIR COLLAR
8190FF
AIRFLOW ADJUSTMENT
THUMBSCREW
E100V
90-2623
90-2624
FIGURE 1 – DAMPER OPERATION
FIGURE 2 – ASSEMBLING AND MOUNTING THE 8190FF
FOR INTERNAL
USE ONLY
AprilairePartners.com
P.O. Box 1467
Madison, WI 53701-1467
800.334.6011 F: 608.257.4357
Printed in USA
©2021 Aprilaire – Division of Research Products Corporation
10015511 B2209230B 2.21
INSTALL DUCTWORK
DUCTING THE 8190FF
1. Install insulated ductwork from the 6" ventilation opening to the
fresh air inlet hood.
2. Tape or mastic the duct to the hood and collar, and seal the duct
insulation on the ends using zip ties or tape.
3. Install ductwork from the 10" 8190FF collar to a location with air
representative of the whole house. If the 10" duct is located in an
unconditioned space such as an attic or garage, use insulated duct
and tape/seal the duct and insulation as you would the fresh air
intake duct. Suggested dehumidifier inlet ducting:
• Install a separate register with 10" collar in the space to be
dehumidified.
• Connect the 10" duct to a return air plenum or to the return
airduct.
Refer to dehumidifier Installation Instructions and Owner’s Manual
for instructions for ducting the dehumidifier to your HVAC system.
WIRING THE 8190FF
Remove/turn off the fuse or circuit breaker that provides/will provide
power to the dehumidifier before starting wiring. Do not restore
power until all wiring is complete.
1. Wiring to the Model E100V dehumidifier (see FIGURE 3).
• Use the included switched-power jumper wire and 2-wire
connector to attach one of the 8190FF wires to one of the VENT
terminals on the dehumidifier user interface.
• Use the power harness included with the E100V dehumidifier
to connect the dehumidifier power port to the unused VENT
terminal and 8190FF wire.
2. Wire to a Model E100 or Model 1850 dehumidifier (see FIGURE 4).
• Use 18-22 AWG wire to attach one of the 8190FF wires to one of
the VENT terminals on the dehumidifier user interface.
• Install the 24VAC transformer, preferably to the junction box used
for the dehumidifier power outlet. Make sure the fuse or circuit
breaker that serves the junction box to which the transformer is
to be wired, has been removed/turned off
• Use 2-wire cable, 22 AWG minimum, to connect the transformer
to the unused VENT terminal and 8190FF wire.
Refer to dehumidifier Installation Instructions and Owner’s Manual
for instructions on wiring and ventilation setup.
+ - A B ODT VENT DEH
Sensor DampersRemote
FLOAT
Switch
DH DH
Gh Rf Cf Gs YW
HVAC EQUIP.
G
R
C
W
Y
R
C
G
W
Y
HVAC
EQUIPMENT
THERMOSTAT
OPTIONAL OUTDOOR TEMPERATURE
SENSOR (MODEL 8052 INCLUDED)
E100V
EXTERNAL
24V PORT
ACTUATOR
+ - A B ODT VENT DEH
Sensor DampersRemote
FLOAT
Switch
DH DH
Gh Rf Cf Gs YW
HVAC EQUIP.
G
R
C
W
Y
R
C
G
W
Y
24 VAC
(10 VA min)
TRANSFORMER
(NOT INCLUDED)
8190FF
ACTUATOR
OPTIONAL OUTDOOR TEMPERATURE
SENSOR (MODEL 8052 INCLUDED)
HVAC
EQUIPMENT
THERMOSTAT
90-2625
90-2626
FIGURE 3 – WIRING INSTRUCTIONS FOR 8190FF TO E100V
FIGURE 4 – WIRING INSTRUCTIONS FOR 8190FF TO OTHER
2