Aqua Free AS Fill season User manual

Instructions for use
www.aqua-free.com
Table of Contents
1 Product and Application
2 Scope of supply and accessories
3 Preparingthelterforrst-timeuse
4 Handlingthelter
5 Durationofuse/Changingthelter
6 Technical data
1 Product and Application
The AS Fill seasonbacterialterisspecicallydesigned
forllingmobiletanksusedinrecreationalvehicles(such
asmotorhomes,caravansorboats)withbacteriafreewater.
Thelterisconnectedtotheendofthellinghoseusinga
standardhoseadaptercreatingaphysicalbarrierforgerms
anddirtparticlesdirectlybeforeentrytothetank.The0.2µm
membraneinsidethelterensuresthatanyharmfulbacteria
orparticlesareblocked.Thisbacterialretentioncomplieswith
theLog7medicalstandardwiththeresultthatonlyclean
waterentersthetankandthedrinkingwatersystem.
Please note the following:
Beforeusingthelterforthersttime,theentiredrinking
watersysteminyourcampervanorboatshouldbe
thoroughlycleanedanddisinfected.Ifyouhaveany
questionsrelatingtocleaning/disinfection,pleasecontact
yourspecialistdealer.
To ensure the safe operation of your lter please read this
information prior to use and follow all instructions carefully.
5 Duration of use / Changing the lter
Dependingonthefrequencyofuseandwaterquality,theltercanbeusedforoneseason(i.e.upto6
monthsafterrst-timeuse).Ifthewaterowissolowastobeinsufcient,theltershouldbechanged
beforethisperiodisup.Connectionsandaccessoriescanbere-used.Pleaseensurethatthedevice
maintainsanimpeccablehygienicandfunctionalcondition.
Changing the lter:
• Layoutanew AS Fill seasonlterforchanging.
• Unscrewtheconnectionsfromtheusedlter,disinfecting/cleaningifnecessary,andscrewthemonto
thenewlter(see3).
• Continueasdescribedin4.
• Disposeoftheusedlterashouseholdwaste.
The manufacturer does not accept any liability for damage to the lter incurred by non-compliance
with these instructions for use.
Intheeventofamalfunction,theproductshouldbereturnedtoAquafree usingthe“ComplaintsReport”
form(canbedownloadedintheServiceareaatwww.aqua-free.com).
GEBR-ANW-ASFillseason-GB-03/2018-V002
AS Fill season
6 Technical data
Abmessungen: L150mmxØ61mm
Dimensions: L150mmxØ61mm
Membrane: Hollow-bremembrane
(microltration)
Bacteriaretention: 99.99999%/Log7
Durationofuse: 1season
(approx.6months,max.
13m3)
Flowrate: 22l/min
(initially,at5bar,20°C)
Operatingpressure: 3bartomax.5bar
Chlorineresistance: ≤10ppm
Connection: G½˝screwthread
Headquarters:
Aqua free GmbH
Winsbergring31
22525Hamburg,Germany
E-mail: [email protected]
Phone: +49(0)4046899990
Fax: +49(0)4046899999
Aqua free Solutions Ltd.
TheMediaCentre,7NorthumberlandStreet
Hudderseld,HD11RL,GreatBritain
E-mail: [email protected]
Phone: +44(0)1484483045

4 Handling the lter
• Useahosewithanappropriateadaptertoconnectthelter.
• Ifasuitableadaptorisnottted,usethesuppliedhose
adapter(5).Attachittothehoseandsecureittightlyto
avoidleaks.
• Removethesealingcapsfromthelterconnectorsandstore
inasafeplace.
• Connectthelterinletconnectortothehoseadapter(5).
Please note the ow direction of the lter (see arrow on the lter).
• Connectthellinghose(4)tothelteroutletconnectorand
inserttheopenendofthehoseintothetank.
• Alternatively,tousethetanklidandangleadaptors(available
asoptionalaccessories)screwthetanklidadaptertothetank
inletandthenconnecttheangleadaptortothelteroutlet.
• Turnonthewatersupplyandstartllingthetank.
• Oncethetankisfull,turnoffthewatersupply,disconnectthe
lterfromthehosesanddrainbriey.
• Usethesealingcapstosealthelterinletandoutletinorder
topreventwaterfromleakingoutandputthelterintothe
storagecaseforasafekeeping.
• Ensurethatthellinghoseandotheraccessoriesareasdryas
possiblebeforeputtingthemtoointothestoragecase.
Important information, please note:
• Afterusingthelterforthersttime,itshouldbeusedregularly,
i.e.atleastevery2-3weeks.Ifthetankisnotlledthisfrequently,
theltershouldberinsedfor1-2minutes(notingtheowdirection)
underacoldtap.
• Inyourowninterests,alwayskeepthellinghose,accessoriesandsealingcapsaswellasthe
lteroutletcleanandmakesurethattheyarenotleftontheground.Thiswillensurethatthe
lteredwaterkeptisfreeofcontamination.
• Protectthelterfromfrost.
• Protectthelterfromdamageanddonotletitfall.
Recommendations:Ifthecampervanorboatisnotusedforalongeroftime,thedrinkingwater
systemshouldbedrainedinfull.Whenusingyourownhose,itshouldbedriedoptimallyafteruse.
Werecommendushingthesupplyhosethoroughlybeforeconnectingthelter.
2 Scope of supply and accessories
Optional accessories
Replacement lter
• Shut-offvalve(A)
• Tanklidadapter1(B)–Universaltanklidadapterwithoverowprotection;exteriorØapprox.74mm,
supportsØapprox.64mm
• Tanklidadapter2(C)–Universaltanklidadapterwithoverowprotectionforvariousbrands,e.g.
Dethleffs,LMC,TMCmodels;exteriorØapprox.77mm,supportsØapprox.65mm
• Angleadaptor(D)
Shut-offvalve(A) Tanklidadapter1(B) Tanklidadapter2(C) Anglepiece(D)
Inlet side
Outlet side
3 Preparing the lter for rst-time use
• Removethelterfromtheexternalpackaging.
• Screwtheconnector(2)tothethreadendsofthelter
(ensurethecorrectpositionofthesealingring).
• Attachasealingcap(3)ontoeachofthe
connectorstopreventcontamination.
AS Fill season bacterial lter: Singlelterforlterchanges,separatepurchase
Scope of supply
AS Fill season set with case:
Storagecasewithbasicaccessories
andbacteriallter
45
31
22
1ASFillseasonfilter
22xG1/2”connectors
36xsealingcaps
4Fillinghosewithadapter
5Hoseadapterfor13mmG½”hose
Flowdirection
Flowdirection
32
Popular Water Dispenser manuals by other brands

IBC Water
IBC Water AST0715MP-960 Installation & operating instructions

Lancaster Water Treatment
Lancaster Water Treatment X FACTOR LX15 Series Installation, operating and service manual

Elkay
Elkay EMABF8 Series Installation & use manual

Oasis
Oasis Osmosis Home installation manual

Monarch Water
Monarch Water ULTIMATE MINI AQUA HE install guide

Haier
Haier HLM-109B instruction manual