Calypso/Titan Second Stage Service Manual
This manual is copyrighted, all rights reserved. It may not, in
whole or in part, be copied, photocopied, reproduced, translated,
or reduced to any electronic medium or machine readable form
without prior consent in writing from Aqua Lung America. It may
not be distributed through the internet or computer bulletin board
systems without prior consent in writing from Aqua Lung America.
©2004 Aqua Lung America, Inc.
Calypso/Titan Second Stage Repair Manual
This manual provides factory prescribed procedures for the cor-
rect service and repair of the Aqua Lung Calypso/Titan second-
stage regulator. It is not intended to be used as an instructional
manual for untrained personnel. The procedures outlined within
this manual are to be performed only by personnel who have re-
ceived factory authorized training through an Aqua Lung Service
& Repair Seminar. If you do not completely understand all of the
procedures outlined in this manual, contact Aqua Lung to speak
directly with a Technical Advisor before proceeding any further.
WARNINGS, CAUTIONS, & NOTES
Pay special attention to information provided in warnings, cau-
tions, and notes that are accompanied by one of these symbols:
WARNINGS
indicate a procedure or situation that
may result in serious injury or death if instructions
are not followed correctly.
indicate any situation or technique
that will result in potential damage to the prod-
uct, or render the product unsafe if instructions
are not followed correctly.
NOTES
are used to emphasize important points, tips, and
If the regulator is subjected to less than 50 dives per year, it is
permissible to overhaul it every other year with an inspection
procedure being performed on the “off” years. For example:
Both Inspections and Overhauls need to be documented in the
Annual Service & Inspection Record
in the back of the Owner’s
Annual Service & Inspection Record in the back of the Owner’s Annual Service & Inspection Record
Limited Lifetime Warranty
Limited Lifetime Warranty in effect.Limited Lifetime Warranty
If a regulator is subjected to more than 50 dives per year, it
should receive the complete overhaul.
An Of cial Inspection consists of:
A pressurized immersion test of the entire unit to check for
Checking for stable intermediate pressure that is within the
Checking for opening effort that is within the acceptable
Checking for smooth operation of the control knob and
A visual inspection of the lter for debris or discoloration.
A visual inspection of the exhaust valve to see that it is in
good shape and that it’s resting against a clean surface.
A visual inspection of the mouthpiece looking for tears or
Pulling back hose protectors and checking that the hoses
are secure in the hose crimps.
If a regulator fails item #1,2,3 or 4 the entire regulator should
be overhauled. If a regulator fails 4,5,6 or 7 it will be up to the
technician’s discretion whether or not a full overhaul is required.
In order to correctly perform the procedures outlined in this
manual, it is important to follow each step exactly in the or-
der given. Read over the entire manual to become familiar
with all procedures before attempting to disassemble the
rst-stage, and to learn which specialty tools and replace-
ment parts will be required. Keep the manual open beside
you for reference while performing each procedure. Do not
All service and repair should be carried out in a work area
speci cally set up and equipped for the task. Adequate
lighting, cleanliness, and easy access to all required tools
are essential for an ef cient repair facility.
As the regulator is disassembled, reusable components
should be segregated and not allowed to intermix with
nonreusable parts or parts from other units. Delicate parts,
including inlet ttings and crowns which contain critical
sealing surfaces, must be protected and isolated from other
parts to prevent damage during the cleaning procedure.
Use only genuine Aqua Lung parts provided in the Calypso/
Titan second-stage overhaul parts kit (p/n 900010). DO
NOT attempt to substitute an Aqua Lung part with another
manufacturer’s, regardless of any similarity in shape or size.
Do not attempt to reuse mandatory replacement parts
under any circumstances, regardless of the amount of use
the product has received since it was manufactured or last
When reassembling, it is important to follow every torque
speci cation prescribed in this manual, using a calibrated
torque wrench. Most parts are made of either marine brass
or plastic, and can be permanently damaged by undue
In order to make the regulator compatible with nitrox up to
40%O2 (EAN40), the regulator must be properly cleaned,
lubricated and assembled using genuine Aqua Lung or
Apeks replacement parts. In addition, assembly must be
carried out in a clean environment using powderless, latex
gloves or equivalent. For more detailed information, be sure
to read Procedure A, Cleaning and Lubrication.