manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aquatop
  6. •
  7. Water Pump
  8. •
  9. Aquatop BREZA AC/DC-PLUS User manual

Aquatop BREZA AC/DC-PLUS User manual

OWNER’S MANUAL
Aquatop’s BREZA AC/DC-PLUS Air Pump is an essential piece of
equipment for aquarists of all levels. With the included AC power
supply, the AC/DC-PLUS can be used as a standard aquarium air
pump, but also offers an ingenious design which combines an AC
power failure sensor with integral back-up battery power! In the
unfortunate event of a power outage or when the standard electri-
cal connection is lost, our battery powered air pump automatically
switches over to back-up battery power when the AC power sensor
cord is plugged in, providing a temporary lift support system for
your aquatic creatures.
The BREZA AC/DC-PLUS’ versatile design also makes it a portable
air pump, perfect for sh bait buckets or for transporting aquatic
creatures. The BREZA AC/DC-PLUS Air Pump will help keep your
sh alive and healthy each day and will protect your aquarium’s
inhabitants during a power outage, even if you’re not around to turn
it on.
To guard against injury, basic safety precautions should be observed,
including the following:
READ ALL SAFETY INSTRUCTIONS BEFORE USE.
DANGER To avoid possible electric shock, special care should be taken
since water is employed around the use of this product. For each of the
following situations, do not attempt to repair yourself: return the appliance
to an authorized service facility for service or discard the appliance.
NOTE: It is your sole responsibility to verify that the plug and the receptacle
are clean and free of moisture and salt buildup at all times. The
receptacle must be free of water, salt, calcium, magnesium and dust.
Failure to do so can cause re,damage to property, and permanent
damage to the product and personal injury not limited to loss of life.
NOTE: Before installing the unit, check for any signs of damage to the
device. If there are any signs of damage to the device,power cable
or plug, do not use and return to place of original purchase.
SAFETY INFO
1. A drip loop must be used with all electrical aquarium devices. A drip
loop is a self-made part of the cord hanging below the receptacle.
(See Fig.1).
2. A GFCI (Ground Fault Circuit Interrupter) should be used in the
branch circuit supplying all power to water pumps and electrical aquarium
equipment. If you do not have a GFCI, we strongly recommend having a
qualied electrician install one prior to operating any aquarium component.
3. Do not plug into extension cord/power strip.
4. Use this product for its intended use only.
5. Never yank or pull the cord from the electrical outlet.
6. Do not operate if the plug or wire is damaged.
7. Verify that hands are dry prior to disconnecting the power.
8. To reduce the risks of electrocution, keep all connections dry.
9. For indoor use only when using AC power supply.
10. In case of product malfunction In the event of product malfunction
return the unit to the vendor of original purchase.
11. Check device for any signs of damage before use.
12. Do not use soaps or detergents when cleaning this device.
Thoroughly clean and rinse with warm water and make sure the
device is completely dry before connecting.
13. Keep this product away from children.
1
INTRODUCTION
When used with AC power:
Standard Air Pump Mode:
A. Plug the power sensor cord into section B shown in Figure 2, then
plug the other end into a power outlet. Once the LCD screen is lit
up, the display will show ON (See Figure 3, #3). The air pump
will begin pumping air at the maximum air output volume (Default
Setting). Touch and hold the power key for 2 seconds to turn OFF
the unit while the LCD screen is lit up.The air pump will stop, and
the power will be turned OFF.
B. As shown in Figure 3, #7 & 8, the +/- keys can be used to control
the air output volume with a total of 18 intensity levels depending
on the users’ requirements.
Emergency Back-up Mode:
Plug the power sensor cord into section B shown in Figure 2, then
plug the other end into a power outlet. The air pump will
automatically power ON. Touch the power key once to turn the unit
off (See Figure 3, #4). The air pump will automatically enter
Emergency Back-up Mode in which there will be no air output at all.
In the unfortunate event of a power outage or when the standard
electrical connection is lost, the air pump automatically switches over
to back-up battery power and will be set at the 15th Output Level
with Intermittent Mode 2 (Default Setting).
When used with DC battery power:
Note: Please ensure that the rechargeable lithium battery is fully
charged before performing the following set-up operations.
A. As shown in Figure 1, touch and hold the power key symbol
located on the lower left corner of LCD screen for
approximately 2 seconds to turn the unit ON. Once the LCD
screen is lit up, the display will show ON (See Figure 3, #3). The
air pump will begin pumping air at the maximum air output
volume (Default Setting). Touch and hold the power key for 2
seconds to turn OFF the unit while the LCD screen is lit up. The
air pump will stop, and the power will be turned OFF.
PROGRAMMABLE AIR PUMP
WITH BATTERY BACKUP
2
WARNINGS & SAFETY
SET-UP INSTRUCTIONS
3
SET-UP INSTRUCTIONS ( CONT’D )
B. As shown in Figure 3, touch the Mode Key (#9) to select
Continuous Mode or Intermittent Mode. There will be no
number displayed while in Continuous Mode, while the display
will show the numbers 1-4 while in Intermittent Mode
(See Fig. 3 #5).
Intermittent Mode 1: The air pump turns on for 2 minutes,
then pauses for 1 minute.
Intermittent Mode 2: The air pump turns on for 2 minutes,
then pauses for 2 minutes.
Intermittent Mode 3: The air pump turns on for 2 minutes,
then pauses for 4 minutes.
Intermittent Mode 4: The air pump turns on for 2 minutes,
then pauses for 6 minutes.
C. As shown in Figure 3, the +/- keys can be used to control the air
output volume with a total of 18 intensity levels depending on
the users’ requirements.
Note: The screen display will automatically lock after 10 seconds
without any activity. To unlock the screen, press any key for 1
second in order to change the settings, or to power the unit OFF.
4
SPECIFICATIONS
5
SET-UP INSTRUCTIONS ( CONT’D )
WARRANTY INFORMATION
AQUATOP 1 YEAR LIMITED WARRANTY
Products are warrantied by AQUATOP®Aquatic Supplies to the
original purchaser against defective material and workmanship
under normal use for a period of 1 year from the date of the
original purchase. Products have no warranty if: 1.) The product
has been serviced, modied or tampered with by anyone other
than AQUATOP Aquatic Supplies, 2.) The product has been
abused or damaged (including broken or cracked bulbs), and/or
3.) The product has been transported without proper packaging.
WARRANTY LIABILITY DISCLAIMER
In no event will Aquatop®be liable for any consequential or
incidental damages, including but not limited to, lost sea life,
personal injury, property damage, equipment damage, lost
prots, lost wages, lost savings, lost income, etc., arising out of
the use of any Aquatop Heater.
For more information on tank health and maintenance as well
as other products carried by Aquatop, visit our website: www.
aquatop.com
6
For more information on tank health and maintenance
as well as other products carried by Aquatop,
visit our website: www.aquatop.com
775 Columbia St. Brea, CA 92821
Tel: (888) 915-27821 (562) 697-9860
www.aquatop.com
V1 /2019
Model Voltage Power Output Pressure Battery
Capacity
ACDC-
PLUS
AC90-
260V
2W
DC 5V
600mAh
1800cc/
min x 2
0.022MPa 4400mAh
Intermittent Mode 1: 22.5 Hrs
Intermittent Mode 2: 30H (Default)
Intermittent Mode 3: 37.5 Hrs
Intermittent Mode 4: 45 Hrs
Continuous Mode: 15 Hrs
BATTERY LIFE
WHAT’S INCLUDED
AQUATOP EXCLUSIVE 1 + 1 EXTENDED WARRANTY
The additional 1 Year Extended Warranty applies when you
REGISTE onlinewith Aquatop. Register your Extended Warranty
at www.aquatop.com
Note: Extended warranty is available for qualifying products.
See www.aquatop.com for a list of qualifying products.
1.0. Terms and Conditions of Guarantee.
1.1. Aquatop warrants to the purchaser, for 1 Year from date of original
purchase through an Authorized Aquatop Reseller, to repair or
replace goods where fault is found due to defective materials
or faulty workmanship and where goods do not operate in
accordance with the instructions.
1.2. All claims for repair or replacement must be made at place of
purchase.
1.3. The original and dated Proof of Purchase (receipt) must be sup
plied with all goods claims. Please also provide this Guarantee
where possible.
1.4. The Guarantee covers the Aquarium against gluing breakdown
resulting in leakage.
1.5. All goods subject to claim under Guarantee should be prepared
for transportation in the original packaging or other comparable
packaging which offers the same degree of protection.
1.6. Where goods are repaired or replaced under Guarantee, these
goods are Guaranteed for the remainder of either the original
Guarantee or Extended Guarantee period.
1.7. Where claims on inspection reveal goods are in normal working
order, Aquatop will request reimbursement of all reasonable costs
incurred.
1.Rechargeable Battery
Power Indicator
2.Air Volume Output Display
3.Power ON Indicator
4.Power OFF Indicator
5.Intermittent Mode Display
6.Power ON/OFF Key
7.Increase Key
8.Decrease Key
9.Mode Key
Figure 3
1
A. LCD Screen
B. Power Cord Port
C. USB Interface
D. Micro USB Interface
Figure 1 Figure 2

Other Aquatop Water Pump manuals

Aquatop MAXFLOW Series User manual

Aquatop

Aquatop MAXFLOW Series User manual

Aquatop BREZA AP20 User manual

Aquatop

Aquatop BREZA AP20 User manual

Aquatop MAXFLOW PH-8 User manual

Aquatop

Aquatop MAXFLOW PH-8 User manual

Aquatop MAXFLOW MCP-1 User manual

Aquatop

Aquatop MAXFLOW MCP-1 User manual

Aquatop MaxFlow NP-305 User manual

Aquatop

Aquatop MaxFlow NP-305 User manual

Aquatop Breza User manual

Aquatop

Aquatop Breza User manual

Aquatop MaxFlow SWP-230 User manual

Aquatop

Aquatop MaxFlow SWP-230 User manual

Popular Water Pump manuals by other brands

VERDER VERDERAIR VA 25 repair parts

VERDER

VERDER VERDERAIR VA 25 repair parts

Debem TR Instructions for use and maintenance

Debem

Debem TR Instructions for use and maintenance

Lincoln industrial PMA-1 owner's manual

Lincoln industrial

Lincoln industrial PMA-1 owner's manual

GEA Hilge TP 1020 operating instructions

GEA

GEA Hilge TP 1020 operating instructions

vacuubrand VACUU-PURE Assembly instructions

vacuubrand

vacuubrand VACUU-PURE Assembly instructions

ITT Hydrovar quick start guide

ITT

ITT Hydrovar quick start guide

WOERNER GMG-LEZ Translation of the original operation manual

WOERNER

WOERNER GMG-LEZ Translation of the original operation manual

Gude GS 4002 Translation of the original instructions

Gude

Gude GS 4002 Translation of the original instructions

EINHELL BG-DP 3730 Original operating instructions

EINHELL

EINHELL BG-DP 3730 Original operating instructions

Pentair ME40T20-R Installation and operation manual

Pentair

Pentair ME40T20-R Installation and operation manual

Annovi Reverberi AR 1604NI instruction manual

Annovi Reverberi

Annovi Reverberi AR 1604NI instruction manual

Pentair SHURFLO 4048 Installation & operation manual

Pentair

Pentair SHURFLO 4048 Installation & operation manual

Vetus HS 1000 installation instructions

Vetus

Vetus HS 1000 installation instructions

Landustrie DCP22 Operation & maintenance manual

Landustrie

Landustrie DCP22 Operation & maintenance manual

Clas Ohlson WWB-07302 instruction manual

Clas Ohlson

Clas Ohlson WWB-07302 instruction manual

KNF N 012 AT. 16 E Operating & installation instructions

KNF

KNF N 012 AT. 16 E Operating & installation instructions

Goulds Pumps 3420 Installation, operation and maintenance manual

Goulds Pumps

Goulds Pumps 3420 Installation, operation and maintenance manual

EUFAB 21048 operating instructions

EUFAB

EUFAB 21048 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.